Polydimethylsiloxane tissue-mimicking phantoms with tunable optical properties

被引:17
|
作者
Goldfain, Aaron M. [1 ]
Lemaillet, Paul [1 ,3 ]
Allen, David W. [1 ]
Briggman, Kimberly A. [2 ]
Hwang, Jeeseong [2 ]
机构
[1] NIST, Sensor Sci Div, Gaithersburg, MD 20899 USA
[2] NIST, Appl Phys Div, Boulder, CO 80309 USA
[3] US FDA, Div Imaging Diagnost & Software Reliabil, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, 10903 New Hampshire Ave, Silver Spring, MD USA
关键词
tissue-mimicking phantom; polydimethylsiloxane; integrating sphere; scattering coefficient spectrum; absorption coefficient spectrum; OPTIMIZED INTEGRATING SPHERE; PRECISE DETERMINATION; INDIA INK; ABSORPTION; CONTRAST;
D O I
10.1117/1.JBO.27.7.074706
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: The polymer, polydimethylsiloxane (PDMS), has been increasingly used to make tissue simulating phantoms due to its excellent processability, durability, flexibility, and limited tunability of optical, mechanical, and thermal properties. We report on a robust technique to fabricate PDMS-based tissue-mimicking phantoms where the broad range of scattering and absorption properties are independently adjustable in the visible- to near-infrared wavelength range from 500 to 850 nm. We also report on an analysis method to concisely quantify the phantoms' broadband characteristics with four parameters. Aim: We report on techniques to manufacture and characterize solid tissue-mimicking phantoms of PDMS polymers. Tunability of the absorption (mu(a) ( lambda ) ) and reduced scattering coefficient spectra (mu s '(lambda)) in the wavelength range of 500 to 850 nm is demonstrated by adjusting the concentrations of light absorbing carbon black powder (CBP) and light scattering titanium dioxide powder (TDP) added into the PDMS base material. Approach: The mu(a) ( lambda ) and mu s '(lambda) of the phantoms were obtained through measurements with a broadband integrating sphere system and by applying an inverse adding doubling algorithm. Analyses of mu(a) ( lambda ) and mu s '(lambda) of the phantoms, by fitting them to linear and power law functions, respectively, demonstrate that independent control of mu(a) ( lambda ) and mu s '(lambda) is possible by systematically varying the concentrations of CBP and TDP. Results: Our technique quantifies the phantoms with four simple fitting parameters enabling a concise tabulation of their broadband optical properties as well as comparisons to the optical properties of biological tissues. We demonstrate that, to a limited extent, the scattering properties of our phantoms mimic those of human tissues of various types. A possible way to overcome this limitation is demonstrated with phantoms that incorporate polystyrene microbead scatterers. Conclusions: Our manufacturing and analysis techniques may further promote the application of PDMS-based tissue-mimicking phantoms and may enable robust quality control and quality checks of the phantoms. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Detection and discrimination of optical absorption and shear stiffness at depth in tissue-mimicking phantoms by transient optoelastography
    Daoudi, Khalid
    Boccara, Albert-Claude
    Bossy, Emmanuel
    APPLIED PHYSICS LETTERS, 2009, 94 (15)
  • [42] Tissue-mimicking phantoms of human retina with consideration to blood circulation for Doppler optical coherence tomography
    Potlov, A. Yu
    Frolov, S., V
    Proskurin, S. G.
    SARATOV FALL MEETING 2019: OPTICAL AND NANO-TECHNOLOGIES FOR BIOLOGY AND MEDICINE,, 2020, 11457
  • [43] Fabrication of a multilayer tissue-mimicking phantom with tunable optical properties to simulate vascular oxygenation and perfusion for optical imaging technology
    Liu, Guangli
    Huang, Kuiming
    Jia, Qiumin
    Liu, Songde
    Shen, Shuwei
    Li, Jialuo
    Dong, Erbao
    Lemaillet, Paul
    Allen, David W.
    Xu, Ronald X.
    APPLIED OPTICS, 2018, 57 (23) : 6772 - 6780
  • [44] Dual-material 3D printed metamaterials with tunable mechanical properties for patient-specific tissue-mimicking phantoms
    Wang, Kan
    Wu, Changsheng
    Qian, Zhen
    Zhang, Chuck
    Wang, Ben
    Vannan, Mani A.
    ADDITIVE MANUFACTURING, 2016, 12 : 31 - 37
  • [45] Optical focusing through biological tissue and tissue-mimicking phantoms up to 9.6 centimeters thick with digital optical phase conjugation
    Shen, Yuecheng
    Liu, Yan
    Ma, Cheng
    Wang, Lihong V.
    ADAPTIVE OPTICS AND WAVEFRONT CONTROL FOR BIOLOGICAL SYSTEMS III, 2017, 10073
  • [46] Measurement of Viscoelastic Properties of Polyacrylamide-Based Tissue-Mimicking Phantoms for Ultrasound Elastography Applications
    Kumar, Kishore
    Andrews, Maneesha E.
    Jayashankar, V.
    Mishra, Ashok K.
    Suresh, S.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (05) : 1224 - 1232
  • [47] MR relaxation times of agar-based tissue-mimicking phantoms
    Antoniou, Anastasia
    Georgiou, Leonidas
    Christodoulou, Theodora
    Panayiotou, Natalie
    Ioannides, Cleanthis
    Zamboglou, Nikolaos
    Damianou, Christakis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [48] Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery
    Amiri, Sara Azizian
    van Berckel, Pieter
    Lai, Marco
    Dankelman, Jenny
    Hendriks, Benno H. W.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (05): : 2616 - 2643
  • [49] Feasibility of noncontact piezoelectric detection of photoacoustic signals in tissue-mimicking phantoms
    Kolkman, Roy G. M.
    Blomme, Erik
    Cool, Tijl
    Bilcke, Mattias
    van Leeuwen, Ton G.
    Steenbergen, Wiendelt
    Grimbergen, Kees A.
    den Heeten, Gerard J.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (05)
  • [50] A Basic Study of Ultrasonic Shear Wave Elastography in Tissue-mimicking Phantoms
    Rengaraju, V.
    da Silva, A. F. F.
    Sack, I.
    Kargel, Ch.
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 55 - +