Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography

被引:16
|
作者
Wong, Sophia S. [1 ]
Vuong, Vivian S. [1 ]
Cunefare, David [2 ]
Farsiu, Sina [2 ,3 ]
Moshiri, Ala [1 ]
Yiu, Glenn [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Dept Ophthalmol, Durham, NC USA
关键词
RETINAL VEIN OCCLUSION; CENTRAL SEROUS CHORIORETINOPATHY; GROWTH-FACTOR THERAPY; DIABETIC-RETINOPATHY; PANRETINAL PHOTOCOAGULATION; NORMAL EYES; REPEATABILITY; DEGENERATION; EDEMA;
D O I
10.1016/j.ajo.2017.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if different types of retinal fluid in the central macula affect the reproducibility of choroidal thickness (CT) measurements on enhanced depth imaging optical coherence tomography (EDI-OCT). DESIGN: Retrospective reliability analysis. METHODS: EDI-OCT images were obtained and the choroidal-scleral junction was analyzed through semiautomated segmentation. CT was measured at the fovea and averaged across the central 3-mm horizontal segment. Demographic data, central macular thickness, and type of fluid present were recorded. Intragrader and intergrader repeatability were assessed using the intraclass correlation coefficient (ICC) and coefficient of repeatability (CR). RESULTS: Of 124 eyes analyzed, 60 (48.4%) had diabetic macular edema, 32 (25.8%) had neovascular age-related macular degeneration, and 32 (25.8%) had other causes of fluid. Intergrader ICC (CR) was 0.95 (74.1 mu m) and 0.96 (63.9 mu m) for subfoveal and average CT, respectively. CR was similar across various causes of retinal fluid, but was worst for subretinal fluid compared to intraretinal or sub-retinal pigment epithelial fluid. CR also worsened with increasing choroidal thickness, but was not affected by retinal thickness. Intragrader repeatability was generally greater than intergrader values, and followed the same trend. CONCLUSIONS: The presence of macular fluid reduces CT measurement reproducibility, particularly in eyes with subretinal fluid and greater choroidal thickness. A difference of 74.1 mu m in subfoveal CT or 63.9 pm in average CT may be necessary to detect true clinical change in eyes with macular fluid. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [31] Repeatability of wide-field choroidal thickness measurements using enhanced-depth imaging optical coherence tomography
    Hoseini-yazdi, Hosein
    Vincent, Stephen J.
    Collins, Michael J.
    Read, Scott A.
    Alonso-caneiro, David
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (03) : 327 - 334
  • [32] Comparison of peripapillary choroidal thickness measurements via spectral domain optical coherence tomography with and without enhanced depth imaging
    Ayyildiz, Onder
    Kucukevcilioglu, Murat
    Ozge, Gokhan
    Koylu, Mehmet Talay
    Ozgonul, Cem
    Gokce, Gokcen
    Mumcuoglu, Tarkan
    Durukan, Ali Hakan
    Mutlu, Fatih Mehmet
    POSTGRADUATE MEDICINE, 2016, 128 (04) : 439 - 443
  • [33] Reproducibility of topographic macular thickness mapping using optical coherence tomography
    Ghanta, RK
    Schuman, JS
    Guedes, VRF
    Drexler, W
    Hertzmark, E
    Miller, VM
    MacNutt, J
    Puliafito, CA
    Fujimoto, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S570 - S570
  • [34] Reproducibility of macular thickness mapping on the commercial optical coherence tomography device
    MacNutt, JM
    Schuman, JS
    Guedes, VRF
    Miller, VM
    Pakter, HM
    Ghanta, RK
    Drexler, W
    Hertzmark, E
    Peiris, ID
    Puliafito, CA
    Fujimoto, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [35] Peripapillary choroidal thickness in Chinese children using enhanced depth imaging optical coherence tomography
    Xi-Shi Wu
    Li-Jun Shen
    Ru-Ru Chen
    Zhe Lyu
    International Journal of Ophthalmology, 2016, (10) : 1451 - 1456
  • [36] THE EFFECTS OF SILDENAFIL CITRATE ON CHOROIDAL THICKNESS AS DETERMINED BY ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY
    Vance, Sushma K.
    Imamura, Yutaka
    Freund, K. Bailey
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (02): : 332 - 335
  • [37] Evaluation of choroidal thickness in retinitis pigmentosa using enhanced depth imaging optical coherence tomography
    Dhoot, Dilsher S.
    Huo, Siya
    Yuan, Alex
    Xu, David
    Srivistava, Sunil
    Ehlers, Justis P.
    Traboulsi, Elias
    Kaiser, Peter K.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (01) : 66 - 69
  • [38] A comparison of two methods to measure choroidal thickness by enhanced depth imaging optical coherence tomography
    Lundberg, Kristian
    Vergmann, Anna Stage
    Vestergaard, Anders Hojslet
    Jacobsen, Nina
    Goldschmidt, Ernst
    Peto, Tunde
    Grauslund, Jakob
    ACTA OPHTHALMOLOGICA, 2019, 97 (01) : 118 - 120
  • [39] CHOROIDAL THICKNESS IN RELATION TO ETHNICITY MEASURED USING ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY
    Karapetyan, Anushavan
    Ouyang, Pingbo
    Tang, Luo Sheng
    Gemilyan, Manik
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (01): : 82 - 90
  • [40] Choroidal thickness and volume in healthy children messured by enhanced depth imaging optical coherence tomography
    Herrera, L.
    Perez Navarro, I.
    Caramello, C.
    Zabadani, K.
    Almenara, C.
    Perez, D.
    Martinez, M.
    Sanchez, A.
    Pinilla, I.
    Esteban, O.
    ACTA OPHTHALMOLOGICA, 2014, 92