Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography

被引:16
|
作者
Wong, Sophia S. [1 ]
Vuong, Vivian S. [1 ]
Cunefare, David [2 ]
Farsiu, Sina [2 ,3 ]
Moshiri, Ala [1 ]
Yiu, Glenn [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Dept Ophthalmol, Durham, NC USA
关键词
RETINAL VEIN OCCLUSION; CENTRAL SEROUS CHORIORETINOPATHY; GROWTH-FACTOR THERAPY; DIABETIC-RETINOPATHY; PANRETINAL PHOTOCOAGULATION; NORMAL EYES; REPEATABILITY; DEGENERATION; EDEMA;
D O I
10.1016/j.ajo.2017.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if different types of retinal fluid in the central macula affect the reproducibility of choroidal thickness (CT) measurements on enhanced depth imaging optical coherence tomography (EDI-OCT). DESIGN: Retrospective reliability analysis. METHODS: EDI-OCT images were obtained and the choroidal-scleral junction was analyzed through semiautomated segmentation. CT was measured at the fovea and averaged across the central 3-mm horizontal segment. Demographic data, central macular thickness, and type of fluid present were recorded. Intragrader and intergrader repeatability were assessed using the intraclass correlation coefficient (ICC) and coefficient of repeatability (CR). RESULTS: Of 124 eyes analyzed, 60 (48.4%) had diabetic macular edema, 32 (25.8%) had neovascular age-related macular degeneration, and 32 (25.8%) had other causes of fluid. Intergrader ICC (CR) was 0.95 (74.1 mu m) and 0.96 (63.9 mu m) for subfoveal and average CT, respectively. CR was similar across various causes of retinal fluid, but was worst for subretinal fluid compared to intraretinal or sub-retinal pigment epithelial fluid. CR also worsened with increasing choroidal thickness, but was not affected by retinal thickness. Intragrader repeatability was generally greater than intergrader values, and followed the same trend. CONCLUSIONS: The presence of macular fluid reduces CT measurement reproducibility, particularly in eyes with subretinal fluid and greater choroidal thickness. A difference of 74.1 mu m in subfoveal CT or 63.9 pm in average CT may be necessary to detect true clinical change in eyes with macular fluid. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [21] Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
    Sala-Puigdollers, Anna
    Zarranz-Ventura, Javier
    Figueras-Roca, Marc
    Hereu, Mireia
    Hernandez, Teresa
    Morato, Montserrat
    Mesquida, Marina
    Llorens, Victor
    Teresa Sainz de la Maza, Maria
    Adan Civera, Alfredo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [22] Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries
    Vuong, Vivian S.
    Moisseiev, Elad
    Cunefare, David
    Farsiu, Sina
    Moshiri, Ala
    Yiu, Glenn
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 104 - 112
  • [23] Evaluation of Choroidal Thickness in Amblyopia Using Enhanced Depth Imaging Optical Coherence Tomography
    Tenlik, Aylin
    Guler, Emre
    Kulak, Ali Ender
    Totan, Yuksel
    Dervisogullari, Mehmet Serdar
    Guragac, Fatma Betul
    CURRENT EYE RESEARCH, 2015, 40 (10) : 1063 - 1067
  • [24] Choroidal thickness in pregnant women measured by enhanced depth imaging optical coherence tomography
    Takahashi, Junichi
    Kado, Masanori
    Mizumoto, Keiko
    Igarashi, Sho
    Kojo, Tsunemaro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (05) : 435 - 439
  • [25] Choroidal thickness in pregnant women measured by enhanced depth imaging optical coherence tomography
    Junichi Takahashi
    Masanori Kado
    Keiko Mizumoto
    Sho Igarashi
    Tsunemaro Kojo
    Japanese Journal of Ophthalmology, 2013, 57 : 435 - 439
  • [26] Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems
    Branchini, Lauren
    Regatieri, Caio V.
    Flores-Moreno, Ignacio
    Baumann, Bernhard
    Fujimoto, James G.
    Duker, Jay S.
    OPHTHALMOLOGY, 2012, 119 (01) : 119 - 123
  • [27] Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines
    Koay, Chiang Ling
    Quo, Matthew Justin
    Subrayan, Visvaraja
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (03) : 655 - 671
  • [28] Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines
    Chiang Ling Koay
    Matthew Justin Quo
    Visvaraja Subrayan
    International Ophthalmology, 2017, 37 : 655 - 671
  • [29] Influence of choroidal thickness on subfoveal choroidal thickness measurement repeatability using enhanced depth imaging optical coherence tomography
    Cho, A. R.
    Choi, Y. J.
    Kim, Y. T.
    EYE, 2014, 28 (10) : 1152 - 1159
  • [30] Influence of choroidal thickness on subfoveal choroidal thickness measurement repeatability using enhanced depth imaging optical coherence tomography
    A R Cho
    Y J Choi
    Y T Kim
    Eye, 2014, 28 : 1151 - 1160