Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography

被引:16
|
作者
Wong, Sophia S. [1 ]
Vuong, Vivian S. [1 ]
Cunefare, David [2 ]
Farsiu, Sina [2 ,3 ]
Moshiri, Ala [1 ]
Yiu, Glenn [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Dept Ophthalmol, Durham, NC USA
关键词
RETINAL VEIN OCCLUSION; CENTRAL SEROUS CHORIORETINOPATHY; GROWTH-FACTOR THERAPY; DIABETIC-RETINOPATHY; PANRETINAL PHOTOCOAGULATION; NORMAL EYES; REPEATABILITY; DEGENERATION; EDEMA;
D O I
10.1016/j.ajo.2017.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if different types of retinal fluid in the central macula affect the reproducibility of choroidal thickness (CT) measurements on enhanced depth imaging optical coherence tomography (EDI-OCT). DESIGN: Retrospective reliability analysis. METHODS: EDI-OCT images were obtained and the choroidal-scleral junction was analyzed through semiautomated segmentation. CT was measured at the fovea and averaged across the central 3-mm horizontal segment. Demographic data, central macular thickness, and type of fluid present were recorded. Intragrader and intergrader repeatability were assessed using the intraclass correlation coefficient (ICC) and coefficient of repeatability (CR). RESULTS: Of 124 eyes analyzed, 60 (48.4%) had diabetic macular edema, 32 (25.8%) had neovascular age-related macular degeneration, and 32 (25.8%) had other causes of fluid. Intergrader ICC (CR) was 0.95 (74.1 mu m) and 0.96 (63.9 mu m) for subfoveal and average CT, respectively. CR was similar across various causes of retinal fluid, but was worst for subretinal fluid compared to intraretinal or sub-retinal pigment epithelial fluid. CR also worsened with increasing choroidal thickness, but was not affected by retinal thickness. Intragrader repeatability was generally greater than intergrader values, and followed the same trend. CONCLUSIONS: The presence of macular fluid reduces CT measurement reproducibility, particularly in eyes with subretinal fluid and greater choroidal thickness. A difference of 74.1 mu m in subfoveal CT or 63.9 pm in average CT may be necessary to detect true clinical change in eyes with macular fluid. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [1] Reproducibility of Peripapillary Choroidal Thickness Measurements with Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography
    Borba, Paula
    Prado, Vitor
    Silva, Paula
    Matsubara, Igor
    Prata, Tiago
    Vessani, Roberto
    Paranhos, Augusto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Reproducibility of Retinal and Choroidal Thickness Measurements in Enhanced Depth Imaging and High-Penetration Optical Coherence Tomography
    Ikuno, Yasushi
    Maruko, Ichiro
    Yasuno, Yoshiaki
    Miura, Masahiro
    Sekiryu, Tetsuju
    Nishida, Kohji
    Iida, Tomohiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (08) : 5536 - 5540
  • [3] Reproducibility of Subfoveal Choroidal Thickness Measurements with Enhanced Depth Imaging by Spectral-Domain Optical Coherence Tomography
    Shao, Lei
    Xu, Liang
    Chen, Chang Xi
    Yang, Li Hong
    Du, Kui Fang
    Wang, Shuang
    Zhou, Jin Qiong
    Wang, Ya Xing
    You, Qi Sheng
    Jonas, Jost B.
    Wei, Wen Bin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 230 - 233
  • [4] Choroidal Thickness and Retinal Thickness in Cystoid Macular Edema on Enhanced Depth Imaging Optical Coherence Tomography
    Leung, Ella
    Garcia, Patricia
    Rosen, Richard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
    Boonarpha, Nattapon
    Zheng, Yalin
    Stangos, Alexandros N.
    Lu, Huiqi
    Raj, Ankur
    Czanner, Gabriela
    Harding, Simon P.
    Nair-Sahni, Jayashree
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (03) : 484 - 491
  • [6] Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
    Nattapon Boonarpha
    Yalin Zheng
    Alexandros N.Stangos
    Huiqi Lu
    Ankur Raj
    Gabriela Czanner
    Simon P.Harding
    Jayashree Nair-Sahni
    International Journal of Ophthalmology, 2015, 8 (03) : 484 - 491
  • [7] Analysis of Macular and Peripapillary Choroidal Thickness in Glaucoma Patients by Enhanced Depth Imaging Optical Coherence Tomography
    Park, Hae-Young Lopilly
    Lee, Na-Young
    Shin, Hae-Young
    Park, Chan Kee
    JOURNAL OF GLAUCOMA, 2014, 23 (04) : 225 - 231
  • [8] Subfoveal choroidal thickness measurements with enhanced depth imaging optical coherence tomography in patients with nanophthalmos
    Demircan, Ali
    Altan, Cigdem
    Osmanbasoglu, Ozen A.
    Celik, Ugur
    Kara, Necip
    Demirok, Ahmet
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (03) : 345 - 349
  • [9] Analysis of macular choroidal thickness in normal Taiwanese eyes by enhanced depth imaging optical coherence tomography
    Chiu, Li-Wen
    Chang, Yo-Chen
    Chen, Kuo-Jen
    Cheng, Kai-Chun
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2023, 39 (12): : 1245 - 1246
  • [10] Repeatability and Reproducibility of Manual Choroidal Volume Measurements Using Enhanced Depth Imaging Optical Coherence Tomography
    Chhablani, Jay
    Barteselli, Giulio
    Wang, Haiyan
    El-Emam, Sharif
    Kozak, Igor
    Doede, Aubrey L.
    Bartsch, Dirk-Uwe
    Cheng, Lingyun
    Freeman, William R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) : 2274 - 2280