摘要
Silver amalgam screen-printed electrodes (AgA-SPEs) were designed, prepared and tested for the first time as perspective representatives among SPEs that allow measuring at high negative potentials. For this purpose, the precise electrochemical (coulometric) preparation procedure for mercury deposition at the silver working electrode surface of the commercial silver-SPE was developed and a universal method of preparing amalgam electrodes from different metal-SPEs was described. An optimal electrolyzer construction for the mercury deposition, electrolyte composition, electrolysis potential, and a way to activate the electrode surface for its uniform coverage by mercury were proposed. The effect of the mercury content in amalgam on the potential of hydrogen evolution (PHE) at AgA-SPEs was investigated. The maximum PHE value (-1979 +/- 4 mV; RSD = 0.17 %; N = 5) was found on AgA-SPE with 50 % (w/w) of Hg content in 0.1 mol L-1 NaOH, which is more negative than in the case of the original silver-SPE for 387 mV (-1592 +/- 12 mV; RSD = 0.69 %; N = 5). Determination of the iodine content in iodinated table salt was used for the AgA-SPEs practical testing. Measurement parameters were optimized for three electrochemical cell arrangements: i) the electrodes area of AgA-SPE was covered by 50 mu L of the sample solution and differential pulse voltammetric (DPV) measurements were carried out; ii) 3-electrode batch arrangement with only working electrode from AgA-SPE connected with an analyzer for DPV-measurements; iii) amperometric measurements in a flow system. The results of iodine analysis by all three methods were consistent with the manufacturer declared values.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Screen-Printed Electrodes (SPE) for In Vitro Diagnostic Purpose
    Mincu, Nicolae-Bogdan
    Lazar, Veronica
    Stan, Dana
    Mihailescu, Carmen Marinela
    Iosub, Rodica
    Mateescu, Andreea Lorena
    DIAGNOSTICS, 2020, 10 (08)
  • [42] Stabilization of lactate oxidase in screen-printed enzyme electrodes
    Hart, AL
    Cox, H
    Janssen, D
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (08): : 833 - 837
  • [43] Characterisation of screen-printed electrodes for detection of heavy metals
    Palchetti, I
    Cagnini, A
    Mascini, M
    Turner, APF
    MIKROCHIMICA ACTA, 1999, 131 (1-2) : 65 - 73
  • [44] AMPEROMETRIC DETERMINATION OF COPPER USING SCREEN-PRINTED ELECTRODES
    SOMASUNDRUM, M
    BANNISTER, JV
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) : 203 - 208
  • [45] Electrochemical quantification of levothyroxine at disposable screen-printed electrodes
    David, Melinda
    Serban, Adrian
    Enache, Teodor Adrian
    Florescu, Monica
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 911
  • [46] Amperometric determination of copper using screen-printed electrodes
    Somasundrum, Mithran
    Bannister, Joe V.
    Sensors and Actuators, B: Chemical, 1993, B15 (1 -3 pt 1) : 203 - 208
  • [47] Deinking of Screen-Printed Electrodes Printed on Invasive Plant-Based Paper
    Kavcic, Urska
    Karlovits, Igor
    Zule, Janja
    SUSTAINABILITY, 2020, 12 (04)
  • [48] Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
    Munteanu, Florentina-Daniela
    Titoiu, Ana Maria
    Marty, Jean-Louis
    Vasilescu, Alina
    SENSORS, 2018, 18 (03):
  • [49] Sensitive electrochemical detection of ciprofloxacin at screen-printed diamond electrodes
    Matsunaga, Tomohiro
    Kondo, Takeshi
    Osasa, Takahiro
    Kotsugai, Akihiro
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Aikawa, Tatsuo
    Tojo, Toshifumi
    Yuasa, Makoto
    CARBON, 2020, 159 (159) : 247 - 254
  • [50] Design and Characterization of Screen-Printed Textile Electrodes for ECG Monitoring
    Achilli, Andrea
    Bonfiglio, Annalisa
    Pani, Danilo
    IEEE SENSORS JOURNAL, 2018, 18 (10) : 4097 - 4107