Screen-printed amalgam electrodes

被引:7
|
作者
Josypcuk, Bohdan [1 ]
Langmaier, Jan [1 ]
Tvorynska, Sofiia [1 ,2 ]
机构
[1] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223, Czech Republic
[2] Charles Univ Prague, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Fac Sci, Hlavova 2030-8, Prague 12843, Czech Republic
关键词
Electrochemistry; Screen-printed electrodes; Silver amalgam; Flow analysis; Iodine determination; SILVER SOLID AMALGAM; ELECTROCHEMICAL BIOSENSORS; TUBULAR DETECTOR; VOLTAMMETRIC DETERMINATION; ENZYMATIC REACTOR; METAL-IONS; PROTEIN; DESIGN;
D O I
10.1016/j.snb.2021.130583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver amalgam screen-printed electrodes (AgA-SPEs) were designed, prepared and tested for the first time as perspective representatives among SPEs that allow measuring at high negative potentials. For this purpose, the precise electrochemical (coulometric) preparation procedure for mercury deposition at the silver working electrode surface of the commercial silver-SPE was developed and a universal method of preparing amalgam electrodes from different metal-SPEs was described. An optimal electrolyzer construction for the mercury deposition, electrolyte composition, electrolysis potential, and a way to activate the electrode surface for its uniform coverage by mercury were proposed. The effect of the mercury content in amalgam on the potential of hydrogen evolution (PHE) at AgA-SPEs was investigated. The maximum PHE value (-1979 +/- 4 mV; RSD = 0.17 %; N = 5) was found on AgA-SPE with 50 % (w/w) of Hg content in 0.1 mol L-1 NaOH, which is more negative than in the case of the original silver-SPE for 387 mV (-1592 +/- 12 mV; RSD = 0.69 %; N = 5). Determination of the iodine content in iodinated table salt was used for the AgA-SPEs practical testing. Measurement parameters were optimized for three electrochemical cell arrangements: i) the electrodes area of AgA-SPE was covered by 50 mu L of the sample solution and differential pulse voltammetric (DPV) measurements were carried out; ii) 3-electrode batch arrangement with only working electrode from AgA-SPE connected with an analyzer for DPV-measurements; iii) amperometric measurements in a flow system. The results of iodine analysis by all three methods were consistent with the manufacturer declared values.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Characterization of Screen-Printed Bioimpedance Electrodes on Nanocellulose Substrate
    Wilkins, Michael D.
    Rivera, Kristina R.
    Martin, Devon
    Bozkurt, Alper Y.
    Lobaton, Edgar J.
    Daniele, Michael A.
    2019 IEEE SENSORS, 2019,
  • [32] Applications of screen-printed electrodes in current environmental analysis
    Li, Meng
    Li, Da-Wei
    Xiu, Guangli
    Long, Yi-Tao
    CURRENT OPINION IN ELECTROCHEMISTRY, 2017, 3 (01) : 137 - 143
  • [33] Polishing of screen-printed electrodes improves IgG adsorption
    Pravda, M
    O'Meara, C
    Guilbault, GG
    TALANTA, 2001, 54 (05) : 887 - 892
  • [34] Screen-printed copper ion-selective electrodes
    Koncki, R
    Tymecki, L
    Zwierkowska, E
    Glab, S
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (04): : 393 - 395
  • [35] Understanding electrogenerated chemiluminescence at graphite screen-printed electrodes
    Alba, Alejandro Fidel
    Luis, Roberto Fernandez-de
    Totoricaguena-Gorrino, Joseba
    Ruiz-Rubio, Leire
    Sanchez, Julia
    Vilas-Vilela, Jose Luis
    Lanceros-Mendez, Senentxu
    Del Campo, Francisco Javier
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 914
  • [36] Dimethylglyoxime modified screen-printed electrodes for nickel determination
    Rosal, Miguel
    Ceto, Xavier
    Serrano, Nuria
    Arino, Cristina
    Esteban, Miquel
    Manuel Diaz-Cruz, Jose
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 839 : 83 - 89
  • [37] Characterisation of Screen-Printed Electrodes for Detection of Heavy Metals
    I. Palchetti
    A. Cagnini
    M. Mascini
    A. P. F. Turner
    Microchimica Acta, 1999, 131 : 65 - 73
  • [38] APPLICATION OF SCREEN-PRINTED ELECTRODES IN BIOCHEMICAL-ANALYSIS
    SCHMIDT, A
    ROHM, I
    RUGER, P
    WEISE, W
    BILITEWSKI, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (8-9): : 607 - 612
  • [39] Screen-printed zeolite-modified carbon electrodes
    Walcarius, A
    Rozanska, S
    Bessière, J
    Wang, J
    ANALYST, 1999, 124 (08) : 1185 - 1190
  • [40] Screen-printed electrodes covered by mercury film or meniscus
    Josypcuk, Bohdan
    Tvorynska, Sofiia
    ELECTROCHIMICA ACTA, 2025, 513