Scoliosis and interspinous decompression with the X-STOP: prospective minimum 1-year outcomes in lumbar spinal stenosis

被引:9
|
作者
Rolfe, Kevin W. [1 ]
Zucherman, James F. [2 ]
Kondrashov, Dimitriy G. [2 ]
Hsu, Ken Y. [2 ]
Nosova, Emily [2 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA 90509 USA
[2] St Marys Spine Ctr, San Francisco, CA 94117 USA
来源
SPINE JOURNAL | 2010年 / 10卷 / 11期
关键词
Scoliosis; X-STOP; Interspinous decompression; Neurogenic intermittent claudication; Lumbar spinal stenosis; RELIABILITY;
D O I
10.1016/j.spinee.2010.08.004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: The X-STOP interspinous decompression device, as a treatment for neurogenic intermittent claudication (NIC) because of lumbar spinal stenosis (LSS), has been shown to be superior to nonoperative control treatment. Current Food and Drug Administration labeling limits X-STOP use to NIC patients with a maximum of 25 degrees concomitant lumbar scoliosis. This value was arrived at arbitrarily by the device developers and is untested. PURPOSE: To determine X-STOP utility for NIC in patients with concomitant lumbar scoliosis. STUDY DESIGN: A prospective, single institution, clinical outcome study comparing patients with scoliosis with patients without scoliosis who underwent X-STOP interspinous decompression for NIC because of LSS. PATIENT SAMPLE: A cohort of 179 consecutive patients, 63 with scoliosis (Cobb angle 11 degrees or more) and 116 without scoliosis, with symptoms attributable to NIC treated between January 2006 and May 2007, were included in the study. OUTCOME MEASURES: All patients completed self-reported preoperative and minimum 1-year postoperative outcome forms. Functional measures included Oswestry Disability Index (ODI), visual analog scale (VAS) pain score, and maximum walking and standing times in minutes. Three questions measured patient satisfaction: How satisfied were you with the procedure (very satisfied, somewhat satisfied, somewhat dissatisfied, or very dissatisfied); Would you have the procedure again? (yes or no); Would you recommend the procedure to a friend? (yes or no). METHODS: Before analysis, the 179 consecutive X-STOP patients were divided into three groups: Group 1 (controls without scoliosis, n=116); Group 2 (low scoliosis: 11-25 degrees, n=41), and Group 3 (high scoliosis: 26 degrees or more, n=22). The three groups were not statistically different for any preoperative functional scores. Groups were analyzed for pre- to postoperative functional change and level of satisfaction. Segmental scoliosis at the treated level was also analyzed. RESULTS: Fifty-six percent of Group 1 and Group 2 patients, but only 18% of Group 3 patients, achieved the success criterion of an ODI improvement of 15 or more points (Group 3 the outlier, p=.004). The satisfaction rate was Group 1, 76%; Group 2, 78%; Group 3, 59% (Group 3 the outlier, p=.0001). On average, all three groups improved for each outcome: Group 1 (ODI 17.3, VAS 2.0, standing time 39 minutes, and walking time 43 minutes), Group 2 (ODI 20.0, VAS 1.9, standing time 65 minutes, and walking time 64 minutes), Group 3 (ODI 7.2, VAS 0.9, standing time 18 minutes, and walking time 16 minutes). There was no statistical relationship between any outcome and segmental scoliosis. CONCLUSIONS: The outcome success rate for the X-STOP procedure to treat NIC is lower in patients with overall lumbar scoliosis more than 25 degrees but is unaltered by segmental scoliosis at the affected level. Although patients and surgeons must be aware that the presence of more than 25 degrees of scoliosis portends less favorable results with X-STOP implantation for NIC because of LSS, success in these patients is not precluded, and selection of treatment must be put into the context of individual patient risk and other treatment options. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:972 / 978
页数:7
相关论文
共 50 条
  • [1] Two-Year Results of X-Stop Interspinous Implant for the Treatment of Lumbar Spinal Stenosis A Prospective Study
    Nandakumar, Anjali
    Clark, Natasha A.
    Smith, Francis W.
    Wardlaw, Douglas
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (01): : 1 - 7
  • [2] Interspinous process decompression with the X-STOP device for lumbar spinal stenosis - A 4-year follow-up study
    Kondrashov, Dimitriy G.
    Hannibal, Matthew
    Hsu, Ken Y.
    Zucherman, James F.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (05): : 323 - 327
  • [3] Interspinous spacer decompression (X-STOP) for lumbar spinal stenosis and degenerative disk disease: A multicenter study with a minimum 3-year follow-up
    Puzzilli, Fabrizio
    Gazzeri, Roberto
    Galarza, Marcelo
    Neroni, Massimiliano
    Panagiotopoulos, Konstantinos
    Bolognini, Andrea
    Callovini, Giorgio
    Agrillo, Umberto
    Alfieri, Alex
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 124 : 166 - 174
  • [4] A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results
    Zucherman, JF
    Hsu, KY
    Hartjen, CA
    Mehalic, TF
    Implicito, DA
    Martin, MJ
    Johnson, DR
    Skidmore, GA
    Vessa, PP
    Dwyer, JW
    Puccio, S
    Cauthen, JC
    Ozuna, RM
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 22 - 31
  • [5] A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results
    J. F. Zucherman
    K. Y. Hsu
    C. A. Hartjen
    T. F. Mehalic
    D. A. Implicito
    M. J. Martin
    D. R. Johnson
    G. A. Skidmore
    P. P. Vessa
    J. W. Dwyer
    S. Puccio
    J. C. Cauthen
    R. M. Ozuna
    European Spine Journal, 2004, 13 : 22 - 31
  • [6] Cost-effectiveness of the X-STOP® Interspinous Spacer for Lumbar Spinal Stenosis A Comparison with Conservative Care and Laminectomy
    Skidmore, Grant
    Ackerman, Stacey J.
    Bergin, Christopher
    Ross, Dan
    Butler, Jesse
    Suthar, Manish
    Rittenberg, Joshua
    SPINE, 2011, 36 (05) : E345 - E356
  • [7] Minimally Invasive Decompression Versus X-Stop in Lumbar Spinal Stenosis A Randomized Controlled Multicenter Study
    Lonne, Greger
    Johnsen, Lars Gunnar
    Rossvoll, Ivar
    Andresen, Hege
    Storheim, Kjersti
    Zwart, John Anker
    Nygaard, Oystein P.
    SPINE, 2015, 40 (02) : 77 - 85
  • [8] High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis
    Verhoof, Olaf J.
    Bron, Johannes L.
    Wapstra, Frits H.
    van Royen, Barend J.
    EUROPEAN SPINE JOURNAL, 2008, 17 (02) : 188 - 192
  • [9] The X STOP interspinous process decompression versus laminectomy for treatment of lumbar spinal stenosis: Economic analysis
    Kondrashov, Dimitriy
    Hannibal, Matthew
    Hsu, Ken
    Zucherman, James
    NEUROSURGERY, 2006, 59 (02) : 458 - 458
  • [10] Change of radiological parameters after interspinous implantation (X-stop®) in degenerative spinal stenosis
    Kim H.-Y.
    Choi B.-W.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (3) : 281 - 285