Scoliosis and interspinous decompression with the X-STOP: prospective minimum 1-year outcomes in lumbar spinal stenosis

被引:9
|
作者
Rolfe, Kevin W. [1 ]
Zucherman, James F. [2 ]
Kondrashov, Dimitriy G. [2 ]
Hsu, Ken Y. [2 ]
Nosova, Emily [2 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA 90509 USA
[2] St Marys Spine Ctr, San Francisco, CA 94117 USA
来源
SPINE JOURNAL | 2010年 / 10卷 / 11期
关键词
Scoliosis; X-STOP; Interspinous decompression; Neurogenic intermittent claudication; Lumbar spinal stenosis; RELIABILITY;
D O I
10.1016/j.spinee.2010.08.004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: The X-STOP interspinous decompression device, as a treatment for neurogenic intermittent claudication (NIC) because of lumbar spinal stenosis (LSS), has been shown to be superior to nonoperative control treatment. Current Food and Drug Administration labeling limits X-STOP use to NIC patients with a maximum of 25 degrees concomitant lumbar scoliosis. This value was arrived at arbitrarily by the device developers and is untested. PURPOSE: To determine X-STOP utility for NIC in patients with concomitant lumbar scoliosis. STUDY DESIGN: A prospective, single institution, clinical outcome study comparing patients with scoliosis with patients without scoliosis who underwent X-STOP interspinous decompression for NIC because of LSS. PATIENT SAMPLE: A cohort of 179 consecutive patients, 63 with scoliosis (Cobb angle 11 degrees or more) and 116 without scoliosis, with symptoms attributable to NIC treated between January 2006 and May 2007, were included in the study. OUTCOME MEASURES: All patients completed self-reported preoperative and minimum 1-year postoperative outcome forms. Functional measures included Oswestry Disability Index (ODI), visual analog scale (VAS) pain score, and maximum walking and standing times in minutes. Three questions measured patient satisfaction: How satisfied were you with the procedure (very satisfied, somewhat satisfied, somewhat dissatisfied, or very dissatisfied); Would you have the procedure again? (yes or no); Would you recommend the procedure to a friend? (yes or no). METHODS: Before analysis, the 179 consecutive X-STOP patients were divided into three groups: Group 1 (controls without scoliosis, n=116); Group 2 (low scoliosis: 11-25 degrees, n=41), and Group 3 (high scoliosis: 26 degrees or more, n=22). The three groups were not statistically different for any preoperative functional scores. Groups were analyzed for pre- to postoperative functional change and level of satisfaction. Segmental scoliosis at the treated level was also analyzed. RESULTS: Fifty-six percent of Group 1 and Group 2 patients, but only 18% of Group 3 patients, achieved the success criterion of an ODI improvement of 15 or more points (Group 3 the outlier, p=.004). The satisfaction rate was Group 1, 76%; Group 2, 78%; Group 3, 59% (Group 3 the outlier, p=.0001). On average, all three groups improved for each outcome: Group 1 (ODI 17.3, VAS 2.0, standing time 39 minutes, and walking time 43 minutes), Group 2 (ODI 20.0, VAS 1.9, standing time 65 minutes, and walking time 64 minutes), Group 3 (ODI 7.2, VAS 0.9, standing time 18 minutes, and walking time 16 minutes). There was no statistical relationship between any outcome and segmental scoliosis. CONCLUSIONS: The outcome success rate for the X-STOP procedure to treat NIC is lower in patients with overall lumbar scoliosis more than 25 degrees but is unaltered by segmental scoliosis at the affected level. Although patients and surgeons must be aware that the presence of more than 25 degrees of scoliosis portends less favorable results with X-STOP implantation for NIC because of LSS, success in these patients is not precluded, and selection of treatment must be put into the context of individual patient risk and other treatment options. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:972 / 978
页数:7
相关论文
共 50 条
  • [31] The Maine Lumbar Spine Study .3. 1-year outcomes of surgical and nonsurgical management of lumbar spinal stenosis
    Atlas, SJ
    Deyo, RA
    Keller, RB
    Chapin, AM
    Patrick, DL
    Long, JM
    Singer, DE
    SPINE, 1996, 21 (15) : 1787 - 1794
  • [32] The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis
    Zongmiao Wan
    Shaobai Wang
    Michal Kozanek
    Qun Xia
    Frederick L. Mansfield
    Guohua Lü
    Kirkham B. Wood
    Guoan Li
    European Spine Journal, 2012, 21 : 400 - 410
  • [33] An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients - Preliminary experiences in 10 consecutive coses
    Lee, JB
    Hida, K
    Seki, T
    Iwasaki, Y
    Minoru, A
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (01): : 72 - 77
  • [34] A prospective study on CT scan outcomes after conservative decompression surgery for lumbar spinal stenosis
    Gunzburg, R
    Keller, TS
    Szpalski, M
    Vandeputte, K
    Spratt, KF
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (03): : 261 - 267
  • [35] Interspinous process device versus conventional decompression for lumbar spinal stenosis: 5-year results of a randomized controlled trial
    Schenck, Catharina D.
    Terpstra, Sietse E. S.
    Moojen, Wouter A.
    van Zwet, Erik
    Peul, Wilco
    Arts, Mark P.
    Vleggeert-Lankamp, Carmen L. A.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (06) : 909 - 917
  • [36] Cost-effectiveness of current treatment strategies for lumbar spinal stenosis: nonsurgical care, laminectomy, and X-STOP Clinical article
    Burnett, Mark G.
    Stein, Sherman C.
    Bartels, Ronald H. M. A.
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (01) : 39 - 46
  • [37] Minimally invasive decompression surgery for lumbar spinal stenosis with degenerative scoliosis: Predictive factors of radiographic and clinical outcomes
    Minamide, Akihito
    Yoshida, Munehito
    Iwahashi, Hiroki
    Simpson, Andrew K.
    Yamada, Hiroshi
    Hashizume, Hiroshi
    Nakagawa, Yukihiro
    Iwasaki, Hiroshi
    Tsutsui, Shunji
    Kagotani, Ryohei
    Sonekatsu, Mayumi
    Sasaki, Takahide
    Shinto, Kazunori
    Deguchi, Tsuyoshi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (03) : 377 - 383
  • [38] mild Interlaminar Decompression for the Treatment of Lumbar Spinal Stenosis Procedure Description and Case Series With 1-year Follow-up
    Wong, Wade H. M.
    CLINICAL JOURNAL OF PAIN, 2012, 28 (06): : 534 - 538
  • [39] Percutaneous image-guided lumbar decompression and interspinous spacers for the treatment of lumbar spinal stenosis: A 2-year Medicare Claims Benchmark Study
    Staats, Peter S.
    Hagedorn, Jonathan M.
    Reece, David E.
    Strand, Natalie H.
    Poree, Lawrence
    PAIN PRACTICE, 2023, 23 (07) : 776 - 784
  • [40] Paradoxical Radiographic Changes of Coflex Interspinous Device with Minimum 2-Year Follow-Up in Lumbar Spinal Stenosis
    Lee, Nam
    Shin, Dong Ah
    Kim, Keung Nyun
    Yoon, Do Heum
    Ha, Yoon
    Shin, Hyun Chul
    Yi, Seong
    WORLD NEUROSURGERY, 2016, 85 : 177 - 184