Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides

被引:80
|
作者
Hua, YS [1 ]
Wainhaus, SB [1 ]
Yang, YN [1 ]
Shen, LX [1 ]
Xiong, YS [1 ]
Xu, XY [1 ]
Zhang, FG [1 ]
Bolton, JL [1 ]
van Breemen, RB [1 ]
机构
[1] Univ Illinois, Coll Pharm, Dept Med Chem & Pharmacognosy, Chicago, IL 60612 USA
关键词
D O I
10.1016/S1044-0305(00)00191-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxymethyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S-1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90](-). The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C-8 position, an S-1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 50 条
  • [41] Comparison of positive and negative ion detection of tea catechins using tandem mass spectrometry and ultra high performance liquid chromatography
    Spacil, Zdenek
    Novakova, Lucie
    Solich, Petr
    FOOD CHEMISTRY, 2010, 123 (02) : 535 - 541
  • [42] Quantitation of cyclic nucleotides in biological samples by negative electrospray tandem mass spectrometry coupled to ion suppression liquid chromatography
    Witters, E
    Roef, L
    Newton, RP
    VanDongen, W
    Esmans, EL
    VanOnckelen, HA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (02) : 225 - 231
  • [43] Determination of azaspiracids in shellfish using liquid chromatography/tandem electrospray mass spectrometry
    Furey, A
    Braña-Magdalena, A
    Lehane, M
    Moroney, C
    James, KJ
    Satake, M
    Yasumoto, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (03) : 238 - 242
  • [44] Determination of gatifloxacin in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 915 - 919
  • [45] A comparison of flavonoid glycosides by electrospray tandem mass spectrometry
    March, RE
    Lewars, EG
    Stadey, CJ
    Miao, XS
    Zhao, XM
    Metcalfe, CD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 248 (1-2) : 61 - 85
  • [46] Liquid chromatography-electrospray tandem mass spectrometry of acidic monoamine metabolites
    Manini, P
    Andreoli, R
    Cavazzini, S
    Bergamaschi, E
    Mutti, A
    Niessen, WNA
    JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (02): : 423 - 431
  • [47] Direct analysis of microcystins by microbore liquid chromatography electrospray ionization ion-trap tandem mass spectrometry
    Zweigenbaum, JA
    Henion, JD
    Beattie, KA
    Codd, GA
    Poon, GK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (04) : 723 - 733
  • [48] Determination of iodoacetic acid using liquid chromatography/electrospray tandem mass spectrometry
    Lau, Benjamin P. -Y.
    Becalski, Adam
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (12) : 1787 - 1791
  • [49] Quantification of vigabatrin in human plasma by liquid chromatography - Electrospray tandem mass spectrometry
    Matar, KM
    Abdel-Hamid, ME
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 395 - 406
  • [50] Liquid chromatography/electrospray tandem mass spectrometry of terpenoid lactones in Ginkgo biloba
    Sun, YK
    Li, WK
    Fitzloff, JF
    van Breemen, RB
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (03): : 373 - 379