Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides

被引:80
|
作者
Hua, YS [1 ]
Wainhaus, SB [1 ]
Yang, YN [1 ]
Shen, LX [1 ]
Xiong, YS [1 ]
Xu, XY [1 ]
Zhang, FG [1 ]
Bolton, JL [1 ]
van Breemen, RB [1 ]
机构
[1] Univ Illinois, Coll Pharm, Dept Med Chem & Pharmacognosy, Chicago, IL 60612 USA
关键词
D O I
10.1016/S1044-0305(00)00191-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxymethyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S-1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90](-). The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C-8 position, an S-1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 50 条
  • [31] Analysis of oxysterols by electrospray tandem mass spectrometry
    Griffiths, WJ
    Wang, YQ
    Alvelius, G
    Liu, S
    Bodin, K
    Sjövall, J
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (03) : 341 - 362
  • [32] Analysis of underivatized polyamines by reversed phase liquid chromatography with electrospray tandem mass spectrometry
    Hakkinen, Merja R.
    Keinanen, Tuomo A.
    Vepsalainen, Jouko
    Khomutov, Alex R.
    Alhonen, Leena
    Janne, Juhani
    Auriola, Seppo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (04) : 625 - 634
  • [33] Analysis of oxysterols by electrospray tandem mass spectrometry
    Griffiths, William J.
    Wang, Yuqin
    Alvelius, Gunvor
    Liu, Suya
    Bodin, Karl
    Sjövall, Jan
    Journal of the American Society for Mass Spectrometry, 2006, 17 (03): : 341 - 362
  • [34] Comparison of supercritical fluid chromatography-tandem mass spectrometry and liquid chromatography-tandem mass spectrometry for the stereoselective analysis of chlorfenvinphos and dimethylvinphos in tobacco
    Yang, Fei
    Cui, Haozhe
    Wang, Chunqiong
    Wang, Ying
    Zhu, Wenjing
    Deng, Huimin
    Liu, Shanshan
    Bian, Zhaoyang
    Lu, Junli
    Tang, Gangling
    Ji, Yuan
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (19)
  • [35] Analysis of carbohydrate heterogeneity in a glycoprotein using liquid chromatography mass spectrometry and liquid chromatography with tandem mass spectrometry
    Kawasaki, N
    Ohta, M
    Hyuga, S
    Hashimoto, O
    Hayakawa, T
    ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) : 297 - 303
  • [36] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [37] Liquid chromatography electrospray tandem mass spectrometry of amino acid conjugates of jasmonic acid under positive and negative ionisation
    Schmidt, J
    Kramell, R
    Schneider, G
    EUROPEAN MASS SPECTROMETRY, 1995, 1 (06): : 573 - 581
  • [38] Determination of buprenorphine in human plasma by gas chromatography positive ion chemical ionization mass spectrometry and liquid chromatography tandem mass spectrometry
    Moody, DE
    Laycock, JD
    Spanbauer, AC
    Crouch, DJ
    Foltz, RL
    Josephs, JL
    Amass, L
    Bickel, WK
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (06) : 406 - 414
  • [39] Liquid chromatography electrospray ionization mass spectrometry and tandem mass spectrometry for the simplification of analytical methods in pesticide residue analysis.
    Stout, SJ
    daCunha, AR
    Picard, GL
    Safarpour, MM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 128 - AGRO
  • [40] Differentiation of betamethasone and dexamethasone using liquid chromatography/positive electrospray tandem mass spectrometry and multivariate statistical analysis
    Antignac, JP
    Le Bizec, B
    Monteau, F
    Andre, F
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01): : 69 - 75