Comparison of negative and positive ion electrospray tandem mass spectrometry for the liquid chromatography tandem mass spectrometry analysis of oxidized deoxynucleosides

被引:80
|
作者
Hua, YS [1 ]
Wainhaus, SB [1 ]
Yang, YN [1 ]
Shen, LX [1 ]
Xiong, YS [1 ]
Xu, XY [1 ]
Zhang, FG [1 ]
Bolton, JL [1 ]
van Breemen, RB [1 ]
机构
[1] Univ Illinois, Coll Pharm, Dept Med Chem & Pharmacognosy, Chicago, IL 60612 USA
关键词
D O I
10.1016/S1044-0305(00)00191-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxymethyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S-1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90](-). The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C-8 position, an S-1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 50 条
  • [1] Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry
    Shoji, Y
    Yotsu-Yamashita, M
    Miyazawa, T
    Yasumoto, T
    ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) : 10 - 17
  • [2] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303
  • [3] Analysis of curcuminoids by positive and negative electrospray ionization and tandem mass spectrometry
    Jiang, HL
    Somogyi, A
    Jacobsen, NE
    Timmermann, BN
    Gang, DR
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (06) : 1001 - 1012
  • [4] Quantitation of glutathione by liquid chromatography/positive electrospray ionization tandem mass spectrometry
    Zhang, Fagen
    Bartels, Michael J.
    Geter, David R.
    Jeong, Yo-Chan
    Schisler, Melissa R.
    Wood, Amanda J.
    Kan, Lynn
    Gollapudi, B. Bhaskar
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (22) : 3608 - 3614
  • [5] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    Chromatographia, 1998, 47 : 72 - 76
  • [6] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [7] Interfacing liquid chromatography with mass spectrometry and tandem mass spectrometry
    Volmer, DA
    Vollmer, DL
    LC GC NORTH AMERICA, 1996, 14 (03) : 236 - +
  • [8] Direct quantitation of hydroxyethylvaline in hemoglobin by liquid chromatography/positive electrospray tandem mass spectrometry
    Zhang, Fagen
    Brzak, Kathy A.
    Pottenger, Lynn H.
    Bartels, Michael J.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1248 : 84 - 92
  • [9] Column liquid chromatography electrospray ionisation tandem mass spectrometry for the analysis of ochratoxin
    Becker, M
    Degelmann, P
    Herderich, M
    Schreier, P
    Humpf, HU
    JOURNAL OF CHROMATOGRAPHY A, 1998, 818 (02) : 260 - 264
  • [10] Analysis of phosphorylated terpenes by electrospray ionization liquid chromatography tandem mass spectrometry
    Ney, I
    Jager, E
    Herderich, M
    Schreier, P
    Schwab, W
    PHYTOCHEMICAL ANALYSIS, 1996, 7 (05) : 233 - 236