Poly(Thiophene)/Graphene Oxide-Modified Electrodes for Amperometric Glucose Biosensing

被引:5
|
作者
Pilo, Maria, I [1 ]
Baluta, Sylwia [2 ]
Loria, Anna C. [1 ]
Sanna, Gavino [1 ]
Spano, Nadia [1 ]
机构
[1] Univ Sassari, Dipartimento Sci Chim Fis Matemat & Nat, Via Vienna 2, I-07100 Sassari, Italy
[2] Wroclaw Univ Sci & Technol, Fac Chem, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
amperometric biosensor; conducting polymers; poly(thiophene); glucose oxidase; graphene oxide; REDUCED GRAPHENE OXIDE; CONDUCTING POLYMER; FILMS; SENSORS; ACID; COPOLYMERIZATION; POLYTHIOPHENE; NANOPARTICLES; SELECTIVITY; DOPAMINE;
D O I
10.3390/nano12162840
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The availability of fast and non-expensive analytical methods for the determination of widespread interest analytes such as glucose is an object of large relevance; this is so not only in the field of analytical chemistry, but also in medicinal and in food chemistry. In this context, electrochemical biosensors have been proposed in different arrangements, according to the mode of electron transfer between the bioreceptor and the electrode. An efficient immobilization of an enzyme on the electrode surface is essential to assure satisfactory analytical performances of the biosensor in terms of sensitivity, limit of detection, selectivity, and linear range of employment. Here, we report the use of a thiophene monomer, (2,5-di(2-thienyl)thieno [3,2-b]thiophene (dTT-bT), as a precursor of an electrogenerated conducting film to immobilize the glucose oxidase (GOx) enzyme on Pt, glassy carbon (GC), and Au electrode surfaces. In addition, the polymer film electrochemically synthetized on a glassy carbon electrode was modified with graphene oxide before the deposition of GOx; the analytical performances of both the arrangements (without and with graphene oxide) in the glucose detection were compared. The biosensor containing graphene oxide showed satisfactory values of linear dynamic range (1.0-10 mM), limit of detection (0.036 mM), and sensitivity (9.4 mu A mM(-1) cm(-2)). Finally, it was tested in the determination of glucose in fruit juices; the interference from fructose, saccharose, and ascorbic acid was evaluated.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] AMPEROMETRIC DETECTION OF PEROXIDES WITH POLY(ANILINOMETHYLFERROCENE)-MODIFIED ENZYME ELECTRODES
    MULCHANDANI, A
    WANG, CL
    WEETALL, HH
    ANALYTICAL CHEMISTRY, 1995, 67 (01) : 94 - 100
  • [42] Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen-printed Electrodes
    Erden, Pinar Esra
    Erdogan, Zehra Ozden
    Ozturk, Funda
    Kocoglu, Irem Okman
    Kilic, Esma
    ELECTROANALYSIS, 2019, 31 (12) : 2368 - 2378
  • [43] Redox-Functionalized Graphene Oxide Architecture for the Development of Amperometric Biosensing Platform
    Dey, Ramendra Sundar
    Raj, C. Retna
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (11) : 4791 - 4798
  • [44] Nickel nanoparticle-chitosan-reduced graphene oxide-modified screen-printed electrodes for enzyme-free glucose sensing in portable microfluidic devices
    Yang, Jiang
    Yu, Ji-Hyuk
    Strickler, J. Rudi
    Chang, Woo-Jin
    Gunasekaran, Sundaram
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 530 - 538
  • [45] Enhancement in Detection of Glucose Based on a Nickel Hexacyanoferrate-Reduced Graphene Oxide-modified Glassy Carbon Electrode
    Lu, Pan
    Liu, Suqin
    Dai, Gaopeng
    Lei, Yuting
    Liang, Ying
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2013, 66 (08) : 983 - 988
  • [46] Amino Acid-Functionalized Electrochemically Reduced Graphene Oxide-Modified Glassy Carbon Electrodes for the Efficient Sensing of Nitrite
    Wang, Peilong
    Liu, Xiao
    Ma, Wei
    Liu, Gen
    Gao, Hui
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11479 - 11492
  • [47] 3D Printed Design-Assisted Multilayered Graphene Oxide-Modified Polymer Glucose Sensor
    Das, Chirantan
    Das, Subham
    Chugh, Vibhas
    Bhattacharjee, Mitradip
    ADVANCED ENGINEERING MATERIALS, 2024, 26 (01)
  • [49] Enhanced performance of pyrrolic N-doped reduced graphene oxide-modified glassy carbon electrodes for dopamine sensing
    Wiench, Piotr
    Gonzalez, Zoraida
    Gryglewicz, Stanislaw
    Menendez, Rosa
    Gryglewicz, Grazyna
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 852
  • [50] Facile fabrication of ascorbic acid reduced graphene oxide-modified electrodes toward electroanalytical determination of sulfamethoxazole in aqueous environments
    Chen, Chiaying
    Chen, Yen-Chun
    Hong, Yu-Ting
    Lee, Ting-Wei
    Huang, Jing-Fang
    CHEMICAL ENGINEERING JOURNAL, 2018, 352 : 188 - 197