Poly(Thiophene)/Graphene Oxide-Modified Electrodes for Amperometric Glucose Biosensing

被引:5
|
作者
Pilo, Maria, I [1 ]
Baluta, Sylwia [2 ]
Loria, Anna C. [1 ]
Sanna, Gavino [1 ]
Spano, Nadia [1 ]
机构
[1] Univ Sassari, Dipartimento Sci Chim Fis Matemat & Nat, Via Vienna 2, I-07100 Sassari, Italy
[2] Wroclaw Univ Sci & Technol, Fac Chem, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
amperometric biosensor; conducting polymers; poly(thiophene); glucose oxidase; graphene oxide; REDUCED GRAPHENE OXIDE; CONDUCTING POLYMER; FILMS; SENSORS; ACID; COPOLYMERIZATION; POLYTHIOPHENE; NANOPARTICLES; SELECTIVITY; DOPAMINE;
D O I
10.3390/nano12162840
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The availability of fast and non-expensive analytical methods for the determination of widespread interest analytes such as glucose is an object of large relevance; this is so not only in the field of analytical chemistry, but also in medicinal and in food chemistry. In this context, electrochemical biosensors have been proposed in different arrangements, according to the mode of electron transfer between the bioreceptor and the electrode. An efficient immobilization of an enzyme on the electrode surface is essential to assure satisfactory analytical performances of the biosensor in terms of sensitivity, limit of detection, selectivity, and linear range of employment. Here, we report the use of a thiophene monomer, (2,5-di(2-thienyl)thieno [3,2-b]thiophene (dTT-bT), as a precursor of an electrogenerated conducting film to immobilize the glucose oxidase (GOx) enzyme on Pt, glassy carbon (GC), and Au electrode surfaces. In addition, the polymer film electrochemically synthetized on a glassy carbon electrode was modified with graphene oxide before the deposition of GOx; the analytical performances of both the arrangements (without and with graphene oxide) in the glucose detection were compared. The biosensor containing graphene oxide showed satisfactory values of linear dynamic range (1.0-10 mM), limit of detection (0.036 mM), and sensitivity (9.4 mu A mM(-1) cm(-2)). Finally, it was tested in the determination of glucose in fruit juices; the interference from fructose, saccharose, and ascorbic acid was evaluated.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [32] Graphene oxide-modified dental adhesive for bonding orthodontic brackets
    Alnatheer, Mohammad
    Alqerban, Ali
    Alhazmi, Hisham
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2021, 110
  • [33] GRAPHENE OXIDE-MODIFIED HYDROXYAPATITE NANOCOMPOSITES IN BIOMEDICAL APPLICATIONS: A REVIEW
    Hashim, Norsuriani Che
    Frankel, Daniel
    Nordin, Darman
    CERAMICS-SILIKATY, 2019, 63 (04) : 426 - 448
  • [34] AMPEROMETRIC GLUCOSE-SENSING ELECTRODES WITH THE USE OF MODIFIED ENZYMES
    MIZUTANI, F
    YABUKI, S
    KATSURA, T
    DIAGNOSTIC BIOSENSOR POLYMERS, 1994, 556 : 41 - 46
  • [35] AMPEROMETRIC GLUCOSE-SENSING ELECTRODES WITH THE USE OF MODIFIED ENZYMES
    MIZUTANI, F
    YABUKI, S
    KATSURA, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 35 - IEC
  • [36] PERMSELECTIVE LIPID POLY(O-PHENYLENEDIAMINE) COATINGS FOR AMPEROMETRIC BIOSENSING OF GLUCOSE
    WANG, J
    WU, H
    ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 683 - 688
  • [37] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    TALANTA, 1991, 38 (01) : 107 - 110
  • [38] Poly(Celestine Blue)-Graphene Oxide Nanohybrid Modified Electrode for Amperometric Determination of Hydrogen Peroxide
    Sangeetha, N. S.
    Ramaprabhu, Sundara
    Narayanan, S. Sriman
    GRAPHENE, 2013, 1 (02) : 136 - 141
  • [39] Composites of Reduced Graphene Oxide/Nickel Submicrorods for Non-Enzymatic Electrochemical Biosensing: Application to Amperometric Glucose Detection
    Mohammadzadeh, Amirmahdi
    Mazaheri, Mozhdeh
    Sedighian, Armin
    Ghanbari, Hajar
    Simchi, Abdolreza
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (08)
  • [40] Amperometric Response of Hydrogen Peroxide at Carbon Nanotubes Paste Electrodes Modified with an Electrogenerated Poly(Fe(III)-5-amino-phenantroline). Analytical Applications for Glucose Biosensing
    Lozano, Maria L.
    Rodriguez, Marcela C.
    Herrasti, Pilar
    Galicia, Laura
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2010, 22 (01) : 128 - 134