Significant energy saving in industrial natural draught furnace: A model-based investigation

被引:3
|
作者
Karem, S. [1 ]
Al-Obaidi, M. A. [2 ]
Alsadaie, S. [3 ]
John, Y. M. [1 ]
Mujtaba, I. M. [1 ]
机构
[1] Informat Univ Bradford, Fac Engn, Dept Chem Engn, Bradford BD7 1DP, W Yorkshire, England
[2] Middle Tech Univ, Tech Inst Baquba, Baquba, Dayala, Iraq
[3] Univ Sirte, Chem Engn Dept, Sirte, Libya
关键词
Oil refinery; Fired Heater; Furnace; Phase conversion; ASPEN HYSIS; Energy Saving;
D O I
10.1016/j.applthermaleng.2021.117829
中图分类号
O414.1 [热力学];
学科分类号
摘要
In all industrial petrochemical plants and refineries, the furnace is the source of heat resulting from fuel combustion with air. The model-based furnace simulation is considered one of the efficient methods help to reduce the energy loss and maintain fixed refinery revenues, conserving energy, and finally reducing external fuel consumption and total fuel cost. In this paper, a model-based simulation is carried out for a natural air draught industrial scale furnace related to Liquified Petroleum Gas (LPG) production plant in Libya to thoroughly investigate the most responsible factors in lowering the furnace butane exit temperature, which is supposed to be two degrees Fahrenheit higher than inlet temperature. Therefore, to resolve this industrial problem, Aspen Hysys V10, coupling with EDR (exchanger design and rating) is used to carry out rigorous model-based simulation. This is specifically used to assess the impact of heat loss from inside the firebox to the surrounding medium and heat loss from the furnace stack and walls, besides the effect of excess air on the furnace efficiency. Furthermore, this research intends to verify whether the operating conditions, such as furnace tubes inlet flow rate, temperature and pumping pressure, are conforming to the upstream process design specifications or need to be adjusted. The results confirm that increasing furnace outlet temperature two degrees Fahrenheit from off specification 190 degrees F instead of 184 degrees F is successfully achieved by decreasing upstream stream flowrate 25% below the operating value and cutback excess air gradually until 20%. Also, the results clarify the necessity of increasing the flue gas temperature by 7% over design condition, to gain a significant reduction of heat loss of 31.6% and reach as low as 35.5 MBtu/hr. This improvement is achieved using optimum operating conditions of an excess air of 20%, and flue gas oxygen content of 3.3% delivered to stack. Accordingly, the furnace efficiency has been increased by 18% to hit 58.9%. Furthermore, the heat loss from the furnace walls can be also reduced by 68% from 5.41 MBtu/hr to 1.7 MBtu/hr by increasing the refractory wall thickness to 6 in., which entails an increase in the furnace efficiency by 3.66% to reach 58.96%. Decreasing the heat loss fraction through the refractory wall, pip doors, expansion windows and refractory hair cracks would also increase the efficiency by 21% to reach a high of 59.7%. Accordingly, a significant reduction in daily fuel consumption is observed, which costs 1.7 M$ per year. The outcomes of this research clearly show the potential of reducing the operation and maintenance costs significantly.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] INDUSTRIAL APPLICATIONS OF MODEL-BASED PREDICTIVE CONTROL
    RICHALET, J
    AUTOMATICA, 1993, 29 (05) : 1251 - 1274
  • [42] Models for Model-Based User-Centric Energy Analysis of Industrial Automation Systems
    Beck, Andreas
    Goehnera, Peter
    COMPLEX ADAPTIVE SYSTEMS, 2011, 6
  • [43] Model-Based Assessment of Energy Efficiency in Industrial Pump Systems: A Case Study Approach
    Lavric, Henrik
    Drobnic, Klemen
    Fiser, Rastko
    APPLIED SCIENCES-BASEL, 2024, 14 (22):
  • [44] Seizure pathways: A model-based investigation
    Karoly, Philippa J.
    Kuhlmann, Levin
    Soudry, Daniel
    Grayden, David B.
    Cook, Mark J.
    Freestone, Dean R.
    PLOS COMPUTATIONAL BIOLOGY, 2018, 14 (10)
  • [45] Industrial Restructuring of Jiangsu Based on the Grey Linear Programming Model Considering Energy-Saving
    Yuan, Chaoqing
    Liu, Sifeng
    ADVANCES IN GREY SYSTEMS RESEARCH, 2010, : 87 - 94
  • [46] Modelling Greenhouse Temperature and Humidity Dynamics in Order to Develop an Energy Saving Model-Based Control Strategy
    Volkaerts, D.
    Youssef, A.
    Ozcan, S. E.
    Exadaktylos, V.
    Berckmans, D.
    INTERNATIONAL SYMPOSIUM ON ADVANCED TECHNOLOGIES AND MANAGEMENT TOWARDS SUSTAINABLE GREENHOUSE ECOSYSTEMS: GREENSYS2011, 2012, 952 : 87 - 91
  • [47] Krill-Herd-Based Investigation for Energy Saving Opportunities in Offshore Liquefied Natural Gas Processes
    Qadeer, Kinza
    Qyyum, Muhammad Abdul
    Lee, Moonyong
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (42) : 14162 - 14172
  • [48] Comprehensive Electric Arc Furnace Model for Simulation Purposes and Model-Based Control
    Fathi, Amirhossein
    Saboohi, Yadollah
    Skrjanc, Igor
    Logar, Vito
    STEEL RESEARCH INTERNATIONAL, 2017, 88 (03)
  • [49] Energy system diagnosis of paper-drying process, Part 2: A model-based estimation of energy-saving potentials
    Chen, Xiaobin
    Li, Jigeng
    Liu, Huanbin
    Yin, Yongjun
    Zhang, Yanzhong
    DRYING TECHNOLOGY, 2016, 34 (10) : 1219 - 1230
  • [50] Model-Based Generation of Natural Language Specifications
    Phan Thu Nhat Vo
    Spichkova, Maria
    SOFTWARE TECHNOLOGIES: APPLICATIONS AND FOUNDATIONS (STAF 2016), 2016, 9946 : 221 - 231