Significant energy saving in industrial natural draught furnace: A model-based investigation

被引:3
|
作者
Karem, S. [1 ]
Al-Obaidi, M. A. [2 ]
Alsadaie, S. [3 ]
John, Y. M. [1 ]
Mujtaba, I. M. [1 ]
机构
[1] Informat Univ Bradford, Fac Engn, Dept Chem Engn, Bradford BD7 1DP, W Yorkshire, England
[2] Middle Tech Univ, Tech Inst Baquba, Baquba, Dayala, Iraq
[3] Univ Sirte, Chem Engn Dept, Sirte, Libya
关键词
Oil refinery; Fired Heater; Furnace; Phase conversion; ASPEN HYSIS; Energy Saving;
D O I
10.1016/j.applthermaleng.2021.117829
中图分类号
O414.1 [热力学];
学科分类号
摘要
In all industrial petrochemical plants and refineries, the furnace is the source of heat resulting from fuel combustion with air. The model-based furnace simulation is considered one of the efficient methods help to reduce the energy loss and maintain fixed refinery revenues, conserving energy, and finally reducing external fuel consumption and total fuel cost. In this paper, a model-based simulation is carried out for a natural air draught industrial scale furnace related to Liquified Petroleum Gas (LPG) production plant in Libya to thoroughly investigate the most responsible factors in lowering the furnace butane exit temperature, which is supposed to be two degrees Fahrenheit higher than inlet temperature. Therefore, to resolve this industrial problem, Aspen Hysys V10, coupling with EDR (exchanger design and rating) is used to carry out rigorous model-based simulation. This is specifically used to assess the impact of heat loss from inside the firebox to the surrounding medium and heat loss from the furnace stack and walls, besides the effect of excess air on the furnace efficiency. Furthermore, this research intends to verify whether the operating conditions, such as furnace tubes inlet flow rate, temperature and pumping pressure, are conforming to the upstream process design specifications or need to be adjusted. The results confirm that increasing furnace outlet temperature two degrees Fahrenheit from off specification 190 degrees F instead of 184 degrees F is successfully achieved by decreasing upstream stream flowrate 25% below the operating value and cutback excess air gradually until 20%. Also, the results clarify the necessity of increasing the flue gas temperature by 7% over design condition, to gain a significant reduction of heat loss of 31.6% and reach as low as 35.5 MBtu/hr. This improvement is achieved using optimum operating conditions of an excess air of 20%, and flue gas oxygen content of 3.3% delivered to stack. Accordingly, the furnace efficiency has been increased by 18% to hit 58.9%. Furthermore, the heat loss from the furnace walls can be also reduced by 68% from 5.41 MBtu/hr to 1.7 MBtu/hr by increasing the refractory wall thickness to 6 in., which entails an increase in the furnace efficiency by 3.66% to reach 58.96%. Decreasing the heat loss fraction through the refractory wall, pip doors, expansion windows and refractory hair cracks would also increase the efficiency by 21% to reach a high of 59.7%. Accordingly, a significant reduction in daily fuel consumption is observed, which costs 1.7 M$ per year. The outcomes of this research clearly show the potential of reducing the operation and maintenance costs significantly.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Development and Properties of Infrared High Radiation Energy-Saving Coatings for Industrial Furnace
    Wang, Guixiang
    Chen, Zhuo
    Pan, Zuofu
    Tang, Hongyun
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [22] Model-Based Sensitivity Analysis and Experimental Investigation of Perlite Grain Expansion in a Vertical Electrical Furnace
    Angelopoulos, Panagiotis M.
    Gerogiorgis, Dimitrios I.
    Paspaliaris, Ioannis
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (50) : 17953 - 17975
  • [23] An Analysis of the Energy Saving Potential in Hebei Province Based on the Evolution of Industrial Structure Model
    Liu, Xin
    Zhang, Yan
    Du, Xiao-Li
    2016 INTERNATIONAL CONFERENCE ON MANAGEMENT, ECONOMICS AND SOCIAL DEVELOPMENT (ICMESD 2016), 2016, : 866 - 869
  • [24] Energy Saving and Management of the Industrial Process Based on An Improved DEA Cross-model
    Geng, Zhiqiang
    Bai, Ju
    Zhu, Qunxiong
    Xu, Yuan
    Han, Yangming
    PROCEEDINGS OF 2018 IEEE 7TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS CONFERENCE (DDCLS), 2018, : 154 - 159
  • [25] Transient model-based operation guidance on blast furnace
    Hashimoto, Yoshinari
    Kitamura, Yohei
    Ohashi, Tomohiro
    Sawa, Yoshitaka
    Kano, Manabu
    CONTROL ENGINEERING PRACTICE, 2019, 82 : 130 - 141
  • [26] Analyzing the overrated performance of model-based predictive control and energy saving strategies in building energy management: A review
    Talib, Abu
    Joe, Jaewan
    JOURNAL OF BUILDING ENGINEERING, 2025, 101
  • [27] PMV inverse model-based indoor thermal environment control for thermal comfort and energy saving
    Xue, Wenping
    Wang, Haisheng
    Li, Kangji
    2022 41ST CHINESE CONTROL CONFERENCE (CCC), 2022, : 5294 - 5299
  • [28] Assessing the performance of model-based energy saving charging strategies in Li-ion cells
    Pozzi, Andrea
    Torchio, Marcello
    Raimondo, Davide M.
    2018 IEEE CONFERENCE ON CONTROL TECHNOLOGY AND APPLICATIONS (CCTA), 2018, : 806 - 811
  • [29] Natural theology as model-based reasoning
    Green, Adam
    RELIGION BRAIN & BEHAVIOR, 2016, 6 (04) : 337 - 342
  • [30] A model-based approach to natural ventilation
    Mahdavi, Ardeshir
    Proeglhoef, Claus
    BUILDING AND ENVIRONMENT, 2008, 43 (04) : 620 - 627