Significant energy saving in industrial natural draught furnace: A model-based investigation

被引:3
|
作者
Karem, S. [1 ]
Al-Obaidi, M. A. [2 ]
Alsadaie, S. [3 ]
John, Y. M. [1 ]
Mujtaba, I. M. [1 ]
机构
[1] Informat Univ Bradford, Fac Engn, Dept Chem Engn, Bradford BD7 1DP, W Yorkshire, England
[2] Middle Tech Univ, Tech Inst Baquba, Baquba, Dayala, Iraq
[3] Univ Sirte, Chem Engn Dept, Sirte, Libya
关键词
Oil refinery; Fired Heater; Furnace; Phase conversion; ASPEN HYSIS; Energy Saving;
D O I
10.1016/j.applthermaleng.2021.117829
中图分类号
O414.1 [热力学];
学科分类号
摘要
In all industrial petrochemical plants and refineries, the furnace is the source of heat resulting from fuel combustion with air. The model-based furnace simulation is considered one of the efficient methods help to reduce the energy loss and maintain fixed refinery revenues, conserving energy, and finally reducing external fuel consumption and total fuel cost. In this paper, a model-based simulation is carried out for a natural air draught industrial scale furnace related to Liquified Petroleum Gas (LPG) production plant in Libya to thoroughly investigate the most responsible factors in lowering the furnace butane exit temperature, which is supposed to be two degrees Fahrenheit higher than inlet temperature. Therefore, to resolve this industrial problem, Aspen Hysys V10, coupling with EDR (exchanger design and rating) is used to carry out rigorous model-based simulation. This is specifically used to assess the impact of heat loss from inside the firebox to the surrounding medium and heat loss from the furnace stack and walls, besides the effect of excess air on the furnace efficiency. Furthermore, this research intends to verify whether the operating conditions, such as furnace tubes inlet flow rate, temperature and pumping pressure, are conforming to the upstream process design specifications or need to be adjusted. The results confirm that increasing furnace outlet temperature two degrees Fahrenheit from off specification 190 degrees F instead of 184 degrees F is successfully achieved by decreasing upstream stream flowrate 25% below the operating value and cutback excess air gradually until 20%. Also, the results clarify the necessity of increasing the flue gas temperature by 7% over design condition, to gain a significant reduction of heat loss of 31.6% and reach as low as 35.5 MBtu/hr. This improvement is achieved using optimum operating conditions of an excess air of 20%, and flue gas oxygen content of 3.3% delivered to stack. Accordingly, the furnace efficiency has been increased by 18% to hit 58.9%. Furthermore, the heat loss from the furnace walls can be also reduced by 68% from 5.41 MBtu/hr to 1.7 MBtu/hr by increasing the refractory wall thickness to 6 in., which entails an increase in the furnace efficiency by 3.66% to reach 58.96%. Decreasing the heat loss fraction through the refractory wall, pip doors, expansion windows and refractory hair cracks would also increase the efficiency by 21% to reach a high of 59.7%. Accordingly, a significant reduction in daily fuel consumption is observed, which costs 1.7 M$ per year. The outcomes of this research clearly show the potential of reducing the operation and maintenance costs significantly.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Mathematical model-based design of an industrial box furnace
    Tudon-Martinez, Juan C.
    Cantu-Perez, Alberto
    Cardenas-Romero, Andrea
    Lozoya-Santos, Jorge de J.
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [2] Energy-saving inferential control of an industrial furnace
    Obika, Masanobu
    Yamamoto, Toru
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2018, 101 (09) : 42 - 47
  • [3] A model-based approach to energy-saving manufacturing control strategies
    Langer, Tino
    Schlegel, Andreas
    Stoldt, Johannes
    Putz, Matthias
    21ST CIRP CONFERENCE ON LIFE CYCLE ENGINEERING, 2014, 15 : 123 - 128
  • [4] A model-based optimization of vapor compression refrigeration system for energy saving
    Kong, Dehao
    Yin, Xiaohong
    Wang, Xinli
    Ding, Xudong
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 5251 - 5255
  • [5] Model-based control of temperature and energy requirements in a fluidised furnace reactor
    Voutetakis, Spyros S.
    Seferlis, Panos
    Papadopoulou, Simira
    Kyriakos, Yorgos
    ENERGY, 2006, 31 (13) : 2418 - 2427
  • [6] Model-based Electrical Energy Analysis of Industrial Automation Systems
    Beck, A.
    Jazdi, N.
    PROCEEDINGS OF 2010 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2010), VOLS. 1-3, 2010,
  • [7] Combining Energy Saving Techniques in Data Centres using Model-Based Analysis
    Postema, Bjorn F.
    Van Damme, Tobias
    De Persis, Claudio
    Tesi, Pietro
    Haverkort, Boudewijn R.
    COMPANION OF THE 2018 ACM/SPEC INTERNATIONAL CONFERENCE ON PERFORMANCE ENGINEERING (ICPE '18), 2018, : 67 - 72
  • [8] Model-Based Identification and Analysis of the Energy Saving Potential in Batch Chemical Processes
    Szijjarto, Andrej
    Papadokonstantakis, Stavros
    Hungerbuehler, Konrad
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (34) : 11170 - 11182
  • [9] An industrial investigation of similarity measures for model-based test case selection
    Simula Research Laboratory, Department of Informatics, University of Oslo, Norway
    Proc. Int. Symp. Softw. Reliab. Eng., (141-150):
  • [10] An approach for model-based energy cost analysis of industrial automation systems
    Andreas Beck
    Peter Göhner
    Energy Efficiency, 2012, 5 : 303 - 319