A novel cooling and power cycle based on the absorption power cycle and booster-assisted ejector refrigeration cycle driven by a low-grade heat source: Energy, exergy and exergoeconomic analysis

被引:58
|
作者
Wang, Yazi [1 ]
Chen, Tian [2 ]
Liang, Yingbo [1 ]
Sun, Huaibo [3 ]
Zhu, Yiping [4 ]
机构
[1] ZhouKou Normal Univ, Zhoukou 466001, Henan, Peoples R China
[2] Wuhan Univ Technol, Wuhan 430070, Hubei, Peoples R China
[3] Fuyang Normal Univ, Fuyuang 236037, Anhui, Peoples R China
[4] Tsinghua Univ, Dept Thermal Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Combined cooling and power; ERC; Booster compressor; APC; LGHS; Exergoeconomic analysis; WATER COMBINED POWER; THERMODYNAMIC ANALYSIS; LOW-TEMPERATURE; SYSTEM DRIVEN; THERMOECONOMIC ANALYSIS; OPTIMIZATION; KALINA; RECOVERY;
D O I
10.1016/j.enconman.2019.112321
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, different renewable sources and energy systems are attracting world attention due to the significant concerns about excessive emissions and the global energy crisis. To achieve both power and cooling supply for users, a new combined cooling and power system is proposed to utilizing low-grade heat sources, such as industrial waste heat, solar energy, and geothermal energy. In this paper, to enhance the efficiency of the traditional power and cooling combined system, a novel system based on the absorption power cycle (APC) and booster-assisted ejector refrigeration system is designed. In the proposed combined power and ejector refrigeration (CPER) cycle, a booster compressor is devised between the ejector and evaporator to enhance the output cooling. The system operates using the low-grade heat source (LGHS). The thermodynamic and thermoeconomics models are developed to analyze the proposed combined power and cooling system, after which, considering the mathematical analysis, the parametric investigation is employed to evaluate the impact of the design parameters on the main performance criteria. The results showed that the proposed system assisted with booster compressor has higher energy efficiency than the traditional APC cycle. The modeling results revealed that the proposed system could provide a cooling capacity of 23.89 kW and the net output power of 18.52 kW by receiving 195.5 kW energy from the low-grade heat source. Also, the first-law efficiency, second-law efficiency, and the total SUCP (Sum unit cost of the product) of the proposed plant are obtained by 21.7%, 52.22%, and 93.52 $/GJ, respectively. From the exergy analysis, it can be inferred that the maximum rate of exergy destruction among all the constitutes of the system belongs to the ejector which constitutes around 27.05% of the overall exergy destruction of system. Besides, the vapor generator 2 is responsible for the 24.31% of total exergy destruction rate. And, the highest cost of exergy destruction corresponds to the condenser followed by ejector. The parametric analysis revealed some valuable results such as a drop in the total SUCP by decreasing vapor generator 1 hot PPTD (Pinch point temperature difference), final absorption temperature, turbine inlet pressure, and LiBr mass fraction. The cooling output capacity is increasing by the increment of vapor generator 1 hot PPTD, turbine inlet pressure, and LiBr mass fraction.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Energy and exergy analysis of an absorption power cycle
    Garcia-Hernando, Nestor
    de Vega, M.
    Soria-Verdugo, Antonio
    Sanchez-Delgado, Sergio
    APPLIED THERMAL ENGINEERING, 2013, 55 (1-2) : 69 - 77
  • [22] ANALYSIS OF A COMBINED POWER AND EJECTOR REFRIGERATION CYCLE FOR LOW TEMPERATURE HEAT SOURCES
    Zheng, Bin
    Weng, Yiwu
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 29 - 34
  • [23] Advanced Exergy and Exergoeconomic Analysis of Cascade Absorption Refrigeration System Driven by Low-Grade Waste Heat
    Yu, Mengxiao
    Cui, Peizhe
    Wang, Yinglong
    Liu, Zhiqiang
    Zhu, Zhaoyou
    Yang, Sheng
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2019, 7 (19) : 16843 - 16857
  • [24] Exergy analysis of Einstein refrigeration cycle capable of using low grade heat source
    Wang, R. J.
    Liu, D. P.
    Xiao, Y.
    Li, G.
    Zhang, L.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 940 - 944
  • [25] Analysis of a novel combined power and ejector-refrigeration cycle
    Yang, Xingyang
    Zheng, Nan
    Zhao, Li
    Deng, Shuai
    Li, Hailong
    Yu, Zhixin
    ENERGY CONVERSION AND MANAGEMENT, 2016, 108 : 266 - 274
  • [26] A combined power and ejector refrigeration cycle for low temperature heat sources
    Zheng, B.
    Weng, Y. W.
    SOLAR ENERGY, 2010, 84 (05) : 784 - 791
  • [27] Energy, exergy, exergoeconomic and exergoenvironmental analysis on a novel parallel double-effect absorption power cycle driven by the geothermal resource
    Zhang, Feng
    Yan, Yongqi
    Liao, Gaoliang
    Jiaqiang, E.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 258
  • [28] Techno-economic assessment of low-grade geothermal heat-driven ejector refrigeration cycle with a flash chamber and a booster compressor
    Chitta Sahana
    Sudipta De
    Subha Mondal
    Clean Technologies and Environmental Policy, 2024, 26 : 1089 - 1106
  • [29] Techno-economic assessment of low-grade geothermal heat-driven ejector refrigeration cycle with a flash chamber and a booster compressor
    Sahana, Chitta
    De, Sudipta
    Mondal, Subha
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2024, 26 (04) : 1089 - 1106
  • [30] Analysis of a Combined Power and Ejector-Refrigeration Cycle Based on Solar Energy
    Sheykhlou, H.
    Jafarmadar, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2016, 40 (01) : 57 - 67