Validation of Computational Fluid Dynamics in CT-based Airway Models with SPECT/CT

被引:155
|
作者
De Backer, Jan W. [1 ]
Vos, Wim G. [1 ]
Vinchurkar, Samir C. [1 ]
Claes, Rita [2 ]
Drollmann, Anton [4 ]
Wulfrank, Denis [5 ]
Parizel, Paul M. [3 ]
Germonpre, Paul [2 ]
De Backer, Wilfried [2 ]
机构
[1] FluidDA, B-2550 Kontich, Belgium
[2] Univ Antwerp Hosp, Dept Resp Med, Antwerp, Belgium
[3] Univ Antwerp Hosp, Dept Radiol, Antwerp, Belgium
[4] Novartis, Basel, Switzerland
[5] AZ Maria Middelares, Dept Nucl Med, Ghent, Belgium
关键词
PARTICLE DEPOSITION; QUANTITATIVE-ANALYSIS; AEROSOL DEPOSITION; GAMMA-SCINTIGRAPHY; IMAGING TECHNIQUES; CYSTIC-FIBROSIS; TECHNEGAS SPECT; ASTHMA; LUNG; FLOW;
D O I
10.1148/radiol.10100322
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the results obtained by using numerical flow simulations with the results of combined single photon emission computed tomography (SPECT) and computed tomography (CT) and to demonstrate the importance of correct boundary conditions for the numerical methods to account for the large amount of interpatient variability in airway geometry. Materials and Methods: This study was approved by all relevant institutional review boards. All patients gave their signed informed consent. In this study, six patients with mild asthma (three men; three women; overall mean age, 46 years +/- 17 [standard deviation]) underwent CT at functional residual capacity and total lung capacity, as well as SPECT/CT. CT data were used for segmentation and computational fluid dynamics (CFD) simulations. A comparison was made between airflow distribution, as derived with (a) SPECT/CT through tracer concentration analysis, (b) CT through lobar expansion measurement, and (c) CFD through flow computer simulation. Also, the heterogeneity of the ventilation was examined. Results: Good agreement was found between SPECT/CT, CT, and CFD in terms of airflow distribution and hot spot detection. The average difference for the internal airflow distribution was less than 3% for CFD and CT versus SPECT/CT. Heterogeneity in ventilation patterns could be detected with SPECT/CT and CFD. Conclusion: This results of this study show that patient-specific computer simulations with appropriate boundary conditions yield information that is similar to that obtained with functional imaging tools, such as SPECT/CT. (C) RSNA, 2010
引用
收藏
页码:854 / 862
页数:9
相关论文
共 50 条
  • [31] MICROSTRUCTURAL MODELS OF TRABECULAR BONE - COMPARISON OF CT-BASED FE MODELS
    Jirousek, O.
    Zlamal, P.
    ENGINEERING MECHANICS 2011, 2011, : 247 - 250
  • [32] Adjustment of Overestimated CT-Based Attenuation Correction on Bone SPECT/CT After Hip-Resurfacing Arthroplasty
    Suzuki, Akira
    Koshida, Kichiro
    Matsubara, Kosuke
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2013, 41 (03) : 203 - 207
  • [33] Accuracy evaluation of CT-based attenuation correction in SPECT with different energy of radioisotopes
    Kim, Seung Jeong
    Kim, Jae Ii
    Kim, Tae Yeop
    Kim, Soo Mee
    Woo, Jae Ryong
    Lee, Jae Sum
    Lee, Ho-Young
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] 3D SPECT/CT-based navigation to the sentinel node in the groin
    Van den Berg, N. S.
    KleinJan, G. H.
    Brouwer, O. R.
    Matheron, H. M.
    Horenblas, S.
    Van der Poel, H. G.
    Olmos, R. A. Valdes
    Van Leeuwen, F. W. B.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S250 - S250
  • [35] Intravenous contrast-enhanced CT can be used for CT-based attenuation correction in clinical 111In-octreotide SPECT/CT
    Klausen T.L.
    Mortensen J.
    de Nijs R.
    Andersen F.L.
    Højgaard L.
    Beyer T.
    Holm S.
    EJNMMI Physics, 2 (1) : 1 - 13
  • [36] Validation and Optimization of Quantitative SPECT/CT
    Razavi, S.
    Klein, R.
    Martineau, P.
    Dinning, S.
    Bryanton, M.
    Zeng, W.
    Zuckier, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S520 - S521
  • [37] A prospective study comparing CT-Based to PET/CT-based radiation treatment planning
    Bradley, K. A.
    Kruser, T. J.
    Bentzen, S. M.
    Anderson, B. M.
    Gondi, V.
    Khuntia, D.
    Perlmann, S.
    Mehta, M. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S68 - S69
  • [38] A Comparison of CT-Based Pancreatic Segmentation Deep Learning Models
    Suri, Abhinav
    Mukherjee, Pritam
    Pickhardt, Perry J.
    Summers, Ronald M.
    ACADEMIC RADIOLOGY, 2024, 31 (11) : 4538 - 4547
  • [39] CT-Based Radiomics Models for Differentiation of Benign and Malignant Thyroid Nodules: A Multicenter Development and Validation Study
    Lin, Shaofan
    Gao, Ming
    Yang, Zehong
    Yu, Ruihuan
    Dai, Zhuozhi
    Jiang, Chuling
    Yao, Yubin
    Xu, Tingting
    Chen, Jiali
    Huang, Kainan
    Lin, Daiying
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (01)
  • [40] Visualization of 3D CT-based anatomical models
    Alaytsev, Innokentiy K.
    Danilova, Tatyana V.
    Manturov, Alexey O.
    Mareev, Gleb O.
    Mareev, Oleg V.
    SARATOV FALL MEETING 2017: LASER PHYSICS AND PHOTONICS XVIII; AND COMPUTATIONAL BIOPHYSICS AND ANALYSIS OF BIOMEDICAL DATA IV, 2018, 10717