Validation of Computational Fluid Dynamics in CT-based Airway Models with SPECT/CT

被引:155
|
作者
De Backer, Jan W. [1 ]
Vos, Wim G. [1 ]
Vinchurkar, Samir C. [1 ]
Claes, Rita [2 ]
Drollmann, Anton [4 ]
Wulfrank, Denis [5 ]
Parizel, Paul M. [3 ]
Germonpre, Paul [2 ]
De Backer, Wilfried [2 ]
机构
[1] FluidDA, B-2550 Kontich, Belgium
[2] Univ Antwerp Hosp, Dept Resp Med, Antwerp, Belgium
[3] Univ Antwerp Hosp, Dept Radiol, Antwerp, Belgium
[4] Novartis, Basel, Switzerland
[5] AZ Maria Middelares, Dept Nucl Med, Ghent, Belgium
关键词
PARTICLE DEPOSITION; QUANTITATIVE-ANALYSIS; AEROSOL DEPOSITION; GAMMA-SCINTIGRAPHY; IMAGING TECHNIQUES; CYSTIC-FIBROSIS; TECHNEGAS SPECT; ASTHMA; LUNG; FLOW;
D O I
10.1148/radiol.10100322
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the results obtained by using numerical flow simulations with the results of combined single photon emission computed tomography (SPECT) and computed tomography (CT) and to demonstrate the importance of correct boundary conditions for the numerical methods to account for the large amount of interpatient variability in airway geometry. Materials and Methods: This study was approved by all relevant institutional review boards. All patients gave their signed informed consent. In this study, six patients with mild asthma (three men; three women; overall mean age, 46 years +/- 17 [standard deviation]) underwent CT at functional residual capacity and total lung capacity, as well as SPECT/CT. CT data were used for segmentation and computational fluid dynamics (CFD) simulations. A comparison was made between airflow distribution, as derived with (a) SPECT/CT through tracer concentration analysis, (b) CT through lobar expansion measurement, and (c) CFD through flow computer simulation. Also, the heterogeneity of the ventilation was examined. Results: Good agreement was found between SPECT/CT, CT, and CFD in terms of airflow distribution and hot spot detection. The average difference for the internal airflow distribution was less than 3% for CFD and CT versus SPECT/CT. Heterogeneity in ventilation patterns could be detected with SPECT/CT and CFD. Conclusion: This results of this study show that patient-specific computer simulations with appropriate boundary conditions yield information that is similar to that obtained with functional imaging tools, such as SPECT/CT. (C) RSNA, 2010
引用
收藏
页码:854 / 862
页数:9
相关论文
共 50 条
  • [21] Impact of CT-based attenuation and scatter correction on myocardial SPECT images
    van Dalen, J. A.
    Sellis, M.
    de Bruin, W. I.
    Wyndaele, D. N. J.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S286 - S286
  • [22] CT-Based Attenuation Correction in I-123-Ioflupane SPECT
    Lange, Catharina
    Seese, Anita
    Schwarzenboeck, Sarah
    Steinhoff, Karen
    Umland-Seidler, Bert
    Krause, Bernd J.
    Brenner, Winfried
    Sabri, Osama
    Kurth, Jens
    Hesse, Swen
    Buchert, Ralph
    PLOS ONE, 2014, 9 (09):
  • [23] VALIDATION OF COMPUTATIONAL FLUID DYNAMICS MODELS FOR INDUSTRIAL APPLICATIONS
    Dzodzo, Milorad B.
    PROCEEDINGS OF 2021 28TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE28), VOL 3, 2021,
  • [24] Quantitative Evaluation of PET/CT and SPECT/CT-based Dosimetry following Yttrium-90 Radioembolization
    Kappadath, S.
    Henry, C.
    Lopez, B.
    Mahvash, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S424 - S425
  • [25] Validation of CT Doses on Hybrid (SPECT/CT and PET/CT) Devices
    Sera, T.
    Porubszky, T.
    Besenyi, Z.
    Bartha, A.
    Papos, M.
    Elek, R.
    Pellet, S.
    Pavics, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S391 - S391
  • [26] Validation of CT-based Attenuation Correction for Multi-Pinhole PSF Reconstruction for Small-Animal SPECT
    Austin, Derek W.
    Feng, Bing
    Mintzer, Robert A.
    Chen, Mu
    Gregor, Jens
    Stuckey, Alan C.
    Wall, Jonathan S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3339 - 3342
  • [27] Validation of a Computational Fluid Dynamics Model for Airway Deposition Using Single-photon Emission Computed Tomography (SPECT)
    Sadafi, H.
    Tousi, N. Monshi
    Lavon, B. R.
    Lanclus, M.
    De Backer, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [28] MICRO CT-BASED VALIDATION OF IRON CONCENTRATION FOR MPI TRACERS
    Debbeler, C.
    Mueller, J.
    Luedtke-Buzug, K.
    2013 INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2013,
  • [29] 3d Simulation Of Heat And Water Vapor Transfer In CT-Based Human Airway Models
    Wu, D.
    Tawhai, M. H.
    Hoffman, E. A.
    Lin, C. -L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [30] CT-based airway changes after smoking cessation in the general population
    Dudurych, Ivan
    Sidorenkov, Grigory
    van Tuinen, Marcel
    Slebos, Dirk-Jan
    de Bock, Geertruida H.
    van den Berge, Maarten
    de Bruijne, Marleen
    Vliegenthart, Rozemarijn
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183