Moderator-collimator-shielding design for neutron radiography systems using 252Cf

被引:14
|
作者
da Silva, AX [1 ]
Crispim, VR [1 ]
机构
[1] Fed Univ Rio De Janeiro, COPPE, Dept Nucl Engn, BR-21945970 Rio De Janeiro, Brazil
关键词
neutron radiography; moderation; collimation; shielding; californium-252;
D O I
10.1016/S0969-8043(00)00291-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper is concerned with the presentation of a study of the general design of an optimized neutron radiography system that utilizes Cf-252. Moderation, collimation and shielding aspects are considered. A Monte Carlo code, MCNP, was used to obtain a maximum and more homogeneous neutron flux in the collimator outlet next to the image plane, taking into account geometric characteristics and an adequate radiation shielding strategy that complies with the radiological protection rules. Among the various moderator materials investigated, the high density polyethylene proved to be the most efficient, with a thermalization factor of 56 cm(2) Using a collimator design assembly it was possible to obtain a normalized thermal neutron flux, at the image plane, equals 6 x 10(-6) n cm(-2) s(-1) at an effective collimator ratio of 7.5, or 3.2 x 10(-7) n cm(-2) s(-1) at an effective collimator ratio of 50. The total dose equivalent rates were significantly reduced by the shielding optimization process. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [41] Time Dependent Neutron Detector Response Simulation for 252Cf
    Prasad, Shikha
    Clarke, Shaun D.
    Miller, Eric C.
    Pozzi, Sara A.
    Larsen, Edward W.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 911 - 914
  • [42] Anomalies of neutron and γ-ray emission in ternary fission of 252Cf
    Han, HY
    Huang, SN
    Shen, GR
    Qiao, Y
    Sun, G
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 1998, 22 (03): : 193 - 199
  • [43] MEASUREMENT OF THE 250CF COMPONENT IN A 252CF NEUTRON SOURCE AT KRISS
    Kim, Jungho
    Park, Hyeonseo
    Choi, Kil-Oung
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 171 - 175
  • [44] 252CF HALF-LIFE DETERMINED BY NEUTRON COUNTING
    DEVOLPI, A
    PORGES, KG
    INORGANIC & NUCLEAR CHEMISTRY LETTERS, 1969, 5 (02): : 111 - &
  • [45] DU PONT BNL INVESTIGATE 252CF FOR NEUTRON THERAPY
    不详
    CHEMICAL & ENGINEERING NEWS, 1968, 46 (41) : 54 - &
  • [46] FORESEEABLE APPLICATION OF CF-252 TO NEUTRON RADIOGRAPHY
    BARTON, JP
    ISOTOPES AND RADIATION TECHNOLOGY, 1970, 7 (03): : 285 - &
  • [47] TRANSMISSION MEASUREMENT OF 252CF FISSION-NEUTRON SPECTRUM
    GREEN, L
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (02): : 606 - &
  • [48] Material recognition by using 252Cf source
    Hao, Xin
    Zhu, Li-Hua
    Stevanato, L.
    Fabris, D.
    Lunardon, M.
    Moretto, S.
    Nebbia, G.
    Pesente, S.
    Viesti, G.
    Sajo-Bohus, L.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (04): : 479 - 482
  • [49] EVALUATION OF CF-252 AS A NEUTRON RADIOGRAPHY SOURCE
    BARTON, JP
    KLOZAR, MF
    ISOTOPES AND RADIATION TECHNOLOGY, 1972, 9 (04): : 396 - &
  • [50] Water-extended polyester neutron shield for a 252Cf neutron source
    Vega-Carrillo, H. R.
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Gallego, E.
    Lorente, A.
    Donaire, I.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 269 - 273