Moderator-collimator-shielding design for neutron radiography systems using 252Cf

被引:14
|
作者
da Silva, AX [1 ]
Crispim, VR [1 ]
机构
[1] Fed Univ Rio De Janeiro, COPPE, Dept Nucl Engn, BR-21945970 Rio De Janeiro, Brazil
关键词
neutron radiography; moderation; collimation; shielding; californium-252;
D O I
10.1016/S0969-8043(00)00291-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper is concerned with the presentation of a study of the general design of an optimized neutron radiography system that utilizes Cf-252. Moderation, collimation and shielding aspects are considered. A Monte Carlo code, MCNP, was used to obtain a maximum and more homogeneous neutron flux in the collimator outlet next to the image plane, taking into account geometric characteristics and an adequate radiation shielding strategy that complies with the radiological protection rules. Among the various moderator materials investigated, the high density polyethylene proved to be the most efficient, with a thermalization factor of 56 cm(2) Using a collimator design assembly it was possible to obtain a normalized thermal neutron flux, at the image plane, equals 6 x 10(-6) n cm(-2) s(-1) at an effective collimator ratio of 7.5, or 3.2 x 10(-7) n cm(-2) s(-1) at an effective collimator ratio of 50. The total dose equivalent rates were significantly reduced by the shielding optimization process. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [21] Design of a setup for 252Cf neutron source for storage and analysis purpose
    Hei Daqian
    Zhuang Haocheng
    Jia Wenbao
    Cheng Can
    Jiang Zhou
    Wang Hongtao
    Chen Da
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 386 : 1 - 3
  • [22] Proton beam dosimetry using a TEPC with a 252Cf neutron calibration
    Nam, Uk-Won
    Park, Won-Kee
    Lee, Jaejin
    Pyo, Jeonghyun
    Moon, Bongkon
    Kim, Sunghwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1459 - 1462
  • [23] Proton beam dosimetry using a TEPC with a 252Cf neutron calibration
    Uk-Won Nam
    Won-Kee Park
    Jaejin Lee
    Jeonghyun Pyo
    Bongkon Moon
    Sunghwan Kim
    Journal of the Korean Physical Society, 2015, 67 : 1459 - 1462
  • [24] Moderation and shielding optimization for a 252Cf based prompt gamma neutron activation analyzer system
    Hadad, Kamal
    Nematollahi, Mohammadreza
    Sadeghpour, Hoda
    Faghihi, Reza
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (17) : 7221 - 7226
  • [25] The neutron flux of a 252Cf neutron activation analysis device using the MCNP code
    Zhao, L
    Johnson, E
    Robinson, L
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 240 (02) : 531 - 534
  • [26] Fast neutron spectra measurement in a copper using a 252Cf standard neutron source
    Schulc, Martin
    Kostal, Michal
    Matej, Zdenek
    Czakoj, Tomas
    Novak, Evzen
    RADIATION PHYSICS AND CHEMISTRY, 2022, 192
  • [27] The effect of neutron field parameters on 252Cf yield
    Klinov, AV
    Toporov, YG
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1687 - 1689
  • [28] Neutron dosimetry for a general 252Cf brachytherapy source
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2803 - 2815
  • [29] PROMPT NEUTRON EMISSION IN 252CF SPONTANEOUS FISSION
    Hambsch, F. -J.
    Oberstedt, S.
    Zeynalov, Sh.
    SEMINAR ON FISSION, 2010, 2011, : 165 - 172
  • [30] Neutron-neutron angular correlations in spontaneous fission of 252Cf
    Gagarski A.M.
    Guseva I.S.
    Sokolov V.E.
    Val'ski G.V.
    Petrov G.A.
    Krinitsin D.O.
    Nikolaev D.V.
    Zavarukhina T.A.
    Petrova V.I.
    Bull. Russ. Acad. Sci. Phys., 2008, 6 (773-777): : 773 - 777