Evaluation of a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system

被引:42
|
作者
Hu, Naonori [1 ,2 ]
Tanaka, Hiroki [2 ]
Kakino, Ryo [1 ]
Yoshikawa, Syuushi [1 ]
Miyao, Mamoru [3 ]
Akita, Kazuhiko [1 ]
Isohashi, Kayako [1 ]
Aihara, Teruhito [1 ]
Nihei, Keiji [1 ,4 ]
Ono, Koji [1 ]
机构
[1] Osaka Med & Pharmaceut Univ, Kansai BNCT Med Ctr, Osaka Fu Takatsuki Shi Daigakumachi 2-7, Takatsuki, Osaka, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Kyoto, Japan
[3] Osaka Med & Pharmaceut Univ Hosp, Cent Dept Radiol, Takatsuki, Osaka, Japan
[4] Osaka Med & Pharmaceut Univ Hosp, Dept Radiat Oncol, Takatsuki, Osaka, Japan
关键词
Boron neutron capture therapy; Treatment planning system; Commissioning; Monte Carlo simulation; COMPUTATIONAL DOSIMETRY; VERIFICATION;
D O I
10.1186/s13014-021-01968-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Boron neutron capture therapy (BNCT) for the treatment of unresectable, locally advanced, and recurrent carcinoma of the head and neck cancer has been approved by the Japanese government for reimbursement under the national health insurance as of June 2020. A new treatment planning system for clinical BNCT has been developed by Sumitomo Heavy Industries, Ltd. (Sumitomo), NeuCure (R) Dose Engine(.) To safely implement this system for clinical use, the simulated neutron flux and gamma ray dose rate inside a water phantom was compared against experimental measurements. Furthermore, to validate and verify the new planning system, the dose distribution inside an anthropomorphic head phantom was compared against a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose calculation program. The simulated results closely matched the experimental results, within 5% for the thermal neutron flux and 10% for the gamma ray dose rate. The dose distribution inside the head phantom closely matched with SERA and the in-house developed dose calculation program, within 3% for the tumour and a difference of 0.3 Gy(w) for the brain.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Treatment Planning
    Huang, J.
    Dunkerley, D.
    Smilowitz, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E546 - E546
  • [42] Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
    Huang, Jessie Y.
    Dunkerley, David
    Smilowitz, Jennifer B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 184 - 193
  • [43] Application of Monte Carlo calculations for validation of a treatment planning system in high dose rate brachytherapy
    Naseri, Alireza
    Mesbahi, Asghar
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2009, 14 (06) : 200 - 204
  • [44] Evaluation of IMRT Plans From Four Treatment Planning Systems Based On Independent Monte Carlo Dose Calculation
    Chi, Z.
    Cao, Y.
    Zhang, Y.
    Liu, D.
    Li, R.
    Qiu, R.
    Han, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] Evaluation of IMRT Plans From Three Treatment Planning Systems Based On Independent Monte Carlo Dose Calculation
    Chi, Z.
    Li, J.
    Jin, L.
    Fan, J.
    Lin, T.
    Xu, Q.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [46] Optimum design of a moderator system based on dose calculation for an accelerator driven Boron Neutron Capture Therapy
    Inoue, R.
    Hiraga, F.
    Kiyanagi, Y.
    APPLIED RADIATION AND ISOTOPES, 2014, 88 : 225 - 228
  • [47] Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
    Fracchiolla, Francesco
    Engwall, Erik
    Janson, Martin
    Tamm, Fredrik
    Lorentini, Stefano
    Fellin, Francesco
    Bertolini, Mattia
    Algranati, Carlo
    Righetto, Roberto
    Farace, Paolo
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 226 - 234
  • [48] Clinical implementation of the PEREGRINE Monte Carlo dose calculation system for photon-beam therapy
    Siantar, CLH
    Bergstrom, PM
    Daly, TP
    Descalle, MA
    Garrett, D
    House, RK
    Knapp, DK
    May, S
    Patterson, RW
    Walling, RS
    Albright, N
    Verhey, L
    Weiczorek, D
    RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 199 - 203
  • [49] 'End to end' validation of a Monte Carlo code for independent dose calculation in a proton pencil beam scanning system
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Farace, P.
    Schwarz, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S78 - S79
  • [50] Validation of Independent IMRT and VMAT Dose Calculation System based on Geant4 Monte Carlo Toolkit
    Choi, H. J.
    Park, H.
    Shin, W. G.
    Kim, J. I.
    Min, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S942