Evaluation of a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system

被引:42
|
作者
Hu, Naonori [1 ,2 ]
Tanaka, Hiroki [2 ]
Kakino, Ryo [1 ]
Yoshikawa, Syuushi [1 ]
Miyao, Mamoru [3 ]
Akita, Kazuhiko [1 ]
Isohashi, Kayako [1 ]
Aihara, Teruhito [1 ]
Nihei, Keiji [1 ,4 ]
Ono, Koji [1 ]
机构
[1] Osaka Med & Pharmaceut Univ, Kansai BNCT Med Ctr, Osaka Fu Takatsuki Shi Daigakumachi 2-7, Takatsuki, Osaka, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Kyoto, Japan
[3] Osaka Med & Pharmaceut Univ Hosp, Cent Dept Radiol, Takatsuki, Osaka, Japan
[4] Osaka Med & Pharmaceut Univ Hosp, Dept Radiat Oncol, Takatsuki, Osaka, Japan
关键词
Boron neutron capture therapy; Treatment planning system; Commissioning; Monte Carlo simulation; COMPUTATIONAL DOSIMETRY; VERIFICATION;
D O I
10.1186/s13014-021-01968-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Boron neutron capture therapy (BNCT) for the treatment of unresectable, locally advanced, and recurrent carcinoma of the head and neck cancer has been approved by the Japanese government for reimbursement under the national health insurance as of June 2020. A new treatment planning system for clinical BNCT has been developed by Sumitomo Heavy Industries, Ltd. (Sumitomo), NeuCure (R) Dose Engine(.) To safely implement this system for clinical use, the simulated neutron flux and gamma ray dose rate inside a water phantom was compared against experimental measurements. Furthermore, to validate and verify the new planning system, the dose distribution inside an anthropomorphic head phantom was compared against a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose calculation program. The simulated results closely matched the experimental results, within 5% for the thermal neutron flux and 10% for the gamma ray dose rate. The dose distribution inside the head phantom closely matched with SERA and the in-house developed dose calculation program, within 3% for the tumour and a difference of 0.3 Gy(w) for the brain.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Heterogeneous head phantom for validating treatment planning system in boron neutron capture therapy
    Wang, Yi-Lian
    Chen, Wei-Lin
    Pan, Zhao-Ming
    Sheu, Rong-Jiun
    APPLIED RADIATION AND ISOTOPES, 2025, 218
  • [32] Clinical implementation of a Monte Carlo treatment planning system
    Ma, CM
    Mok, E
    Kapur, A
    Pawlicki, T
    Findley, D
    Brain, S
    Forster, K
    Boyer, AL
    MEDICAL PHYSICS, 1999, 26 (10) : 2133 - 2143
  • [33] Clinical treatment planning of subjects undergoing boron neutron capture therapy
    Zamenhof, RG
    Solares, GR
    Kiger, WS
    Riley, KJ
    Busse, PM
    Fischer, E
    Norregaard, T
    Harling, OK
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : B614 - B620
  • [34] Monte Carlo calculations of epithermal and fast neutron dose in a human head model for Boron Neutron Capture Therapy
    Tyminska, Katarzyna
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (02) : 79 - 85
  • [35] Source modeling for Monte Carlo dose calculation of CT examinations with a radiotherapy treatment planning system
    Kallman, Hans-Erik
    Holmberg, Rickard
    Andersson, Jonas
    Kull, Love
    Traneus, Erik
    Ahnesjo, Anders
    MEDICAL PHYSICS, 2016, 43 (11) : 6118 - 6128
  • [36] Dosemetric Uncertainties in the Electron Monte Carlo Dose Calculation Algorithm in the Eclipse Treatment Planning System
    Kendall, E.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E249 - E250
  • [37] MCDOSE - A Monte Carlo dose calculation tool for radiation therapy treatment planning
    Ma, CM
    Li, JS
    Pawlicki, T
    Jiang, SB
    Deng, J
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 123 - 125
  • [38] Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):
  • [39] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations
    Mesbahi, Asghar
    Thwaites, David I.
    Reilly, Andrew J.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (03) : 123 - 133
  • [40] A Monte Carlo calculation of the change in dosimetric properties on the usage of heavy water for boron neutron capture therapy
    Lee, W
    Kim, EH
    Cho, GS
    Lee, SH
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1225 - 1229