Comparison between linear frequency-modulated ultrasonic excitation signals and pure tones for concrete applications

被引:0
|
作者
Dourado, Tiago C. [1 ,2 ]
Costa-Felix, Rodrigo P. B. [1 ]
Peters, Franciane C. [2 ,3 ]
Mansur, Webe J. [2 ,3 ]
机构
[1] Natl Inst Metrol Qual & Technol INMETRO, Directory Sci & Ind Metrol DIMCI, Lab Ultrasound LABUS, Duque De Caxias, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Dept Civil Engn, Modelling Methods Engn & Geophys Lab LAMEMO, COPPE, Rio De Janeiro, RJ, Brazil
[3] Univ Fed Rio de Janeiro, COPPE, Civil Engn Dept, Rio De Janeiro, RJ, Brazil
关键词
Ultrasonic velocity; Transit time; Concrete; Chirp; Pure tone; Non-destructive testing; WAVE-PROPAGATION;
D O I
10.1016/j.apacoust.2022.108977
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Non-destructive testing has supported prognosis and health management in the construction industry for decades. Among them, ultrasonic tests (UT) are increasingly used to assess the structural integrity of the concrete. Typically, the UT uses pure tones as the excitation signal. However, an alternative is to use a linear frequency-modulated pulse (LFMP) followed by compression. This process improves the signal-to-noise ratio, provides broadband frequency responses, and is less susceptible to propagation dispersion. This work compared the ultrasonic transit times (UTT) of LFMP and pure tones. Three nondispersive mod-els for concrete materials were numerically simulated using the k-Wave MATLAB toolbox. Additionally, a sample of reactive powder concrete (RPC) was experimentally tested. The frequencies ranged from 50 kHz to 750 kHz for both simulations and experiments. The simulation results presented LFMP relative errors in UTTs ranging from 0.0 % to 2.7 % compared to the theoretical values, whereas for pure tones, the RE was 2 % to 63 %. Experimentally, as no theoretical value can be considered, the quantitative compar-ison was the measurement dispersion under repeatability conditions. LFMPs disclosed a standard devia-tion in transit time of 35 ns, whereas for pure tones, it ranged from 43 to 51 ns. This research reinforces the potential of LFMP excitation compared to traditional pure tones, providing more accurate and precise ultrasonic velocity measurements in heterogeneous environments.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 42 条
  • [41] The effect of signal duration on the underwater detection thresholds of a harbor porpoise (Phocoena phocoena) for single frequency-modulated tonal signals between 0.25 and 160 kHz
    Kastelein, Ronald A.
    Hoek, Lean
    de Jong, Christ A. F.
    Wensveen, Paul J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 128 (05): : 3211 - 3222
  • [42] Frequency-modulated continuous-wave laser ranging using low-duty-cycle signals for the applications of real-time super-resolved ranging
    Xu, Zhongyang
    Sun, Xiuyuan
    Yu, Fengxi
    Chen, Kai
    Pan, Shilong
    OPTICS LETTERS, 2021, 46 (02) : 258 - 261