Comparison between linear frequency-modulated ultrasonic excitation signals and pure tones for concrete applications

被引:0
|
作者
Dourado, Tiago C. [1 ,2 ]
Costa-Felix, Rodrigo P. B. [1 ]
Peters, Franciane C. [2 ,3 ]
Mansur, Webe J. [2 ,3 ]
机构
[1] Natl Inst Metrol Qual & Technol INMETRO, Directory Sci & Ind Metrol DIMCI, Lab Ultrasound LABUS, Duque De Caxias, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Dept Civil Engn, Modelling Methods Engn & Geophys Lab LAMEMO, COPPE, Rio De Janeiro, RJ, Brazil
[3] Univ Fed Rio de Janeiro, COPPE, Civil Engn Dept, Rio De Janeiro, RJ, Brazil
关键词
Ultrasonic velocity; Transit time; Concrete; Chirp; Pure tone; Non-destructive testing; WAVE-PROPAGATION;
D O I
10.1016/j.apacoust.2022.108977
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Non-destructive testing has supported prognosis and health management in the construction industry for decades. Among them, ultrasonic tests (UT) are increasingly used to assess the structural integrity of the concrete. Typically, the UT uses pure tones as the excitation signal. However, an alternative is to use a linear frequency-modulated pulse (LFMP) followed by compression. This process improves the signal-to-noise ratio, provides broadband frequency responses, and is less susceptible to propagation dispersion. This work compared the ultrasonic transit times (UTT) of LFMP and pure tones. Three nondispersive mod-els for concrete materials were numerically simulated using the k-Wave MATLAB toolbox. Additionally, a sample of reactive powder concrete (RPC) was experimentally tested. The frequencies ranged from 50 kHz to 750 kHz for both simulations and experiments. The simulation results presented LFMP relative errors in UTTs ranging from 0.0 % to 2.7 % compared to the theoretical values, whereas for pure tones, the RE was 2 % to 63 %. Experimentally, as no theoretical value can be considered, the quantitative compar-ison was the measurement dispersion under repeatability conditions. LFMPs disclosed a standard devia-tion in transit time of 35 ns, whereas for pure tones, it ranged from 43 to 51 ns. This research reinforces the potential of LFMP excitation compared to traditional pure tones, providing more accurate and precise ultrasonic velocity measurements in heterogeneous environments.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 42 条
  • [21] A COMPARATIVE STUDY BETWEEN FREQUENCY-MODULATED CONTINUOUS WAVE LADAR AND LINEAR MODE LIDAR
    Massaro, R. D.
    Anderson, J. E.
    Nelson, J. D.
    Edwards, J. D.
    ISPRS TECHNICAL COMMISSION I SYMPOSIUM, 2014, 40-1 : 233 - 239
  • [22] Congruence of Frequency-Dependent Spatial Coherence Between Linear Frequency-Modulated Pulses and Conventional Pulses
    Long, James
    Bottenus, Nick
    Trahey, Gregg E.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [23] Comparison of Amplitude Modulated Sounds and Pure Tones at the Tinnitus Frequency: Residual Tinnitus Suppression and Stimulus Evaluation
    Neff, Patrick
    Zielonka, Lisa
    Meyer, Martin
    Langguth, Berthold
    Schecklmann, Martin
    Schlee, Winfried
    TRENDS IN HEARING, 2019, 23
  • [24] A performance comparison between m-sequences and linear frequency-modulated sweeps for the estimation of travel-time with a moving source
    Gemba, Kay L.
    Vazquez, Heriberto J.
    Fialkowski, Joseph
    Edelmann, Geoffrey F.
    Dzieciuch, Matthew A.
    Hodgkiss, William S.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (04): : 2613 - 2623
  • [25] Efficient Synthesis of Broadband Linear Frequency-Modulated Quadrature Signals for Coherent Electro-Optical Sensor Systems
    Schmidt, Marius
    Carlowitz, Christian
    2024 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, IMS 2024, 2024, : 257 - 260
  • [26] Parameter Design of Linear Frequency Modulated Excitation Waveform for Ultrasonic Nondestructive Testing of Metallic Materials
    Sen Cong
    Tie Gang
    Jiaying Zhang
    Chaoyang Sheng
    Journal of Nondestructive Evaluation, 2014, 33 : 684 - 693
  • [27] Parameter Design of Linear Frequency Modulated Excitation Waveform for Ultrasonic Nondestructive Testing of Metallic Materials
    Cong, Sen
    Gang, Tie
    Zhang, Jiaying
    Sheng, Chaoyang
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2014, 33 (04) : 684 - 693
  • [28] High-frequency ultrasonic echo deconvolution and defect detection of flip chip with linear frequency modulated excitation
    Su, Lei
    Xie, Wanlong
    Ming, Xuefei
    Gu, Jiefei
    Zhao, Xinwei
    Li, Ke
    Pecht, Michael
    Shengxue Xuebao/Acta Acustica, 2025, 50 (01): : 128 - 137
  • [29] Pulse-echo ultrasonic digital system for distance measurements using linear frequency modulated signals
    Gabbani, Valerio
    Rocchi, Santina
    Vignoli, Valerio
    2000, AEI, Milan, Italy (12):
  • [30] A Comparison Between Instantaneous Frequency Estimation Methods of Frequency Modulated Signals Covered with Gaussian Noise
    Romulus, Reiz