A Simple Measurement Method of Common Source Inductance for GaN Devices

被引:0
|
作者
Wu, Jiarui [1 ]
Yang, Xu [1 ]
Wang, Kangping [1 ]
Wei, Jiwen [1 ]
Qi, Zhiyuan [1 ]
Chen, Wenjie [1 ]
Chen, Qiaoliang [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Peoples R China
[2] Longteng Semicond Co Ltd, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
common source inductance; gallium nitride; double pules; measurement;
D O I
10.1109/ECCE47101.2021.9595259
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Common source inductance can increase switching losses and cause false triggering. Therefore, in order to further improve the switching frequency of high frequency converters, it is important to accurately measure the value of this inductance. However, the measurement of common source inductance is constrained by some practical conditions, such as the size of the common source inductance related to the layout and the coupling between the power and drive loops. This thesis proposes a low-cost and easy measurement method that can overcome these limitations. A double pulse circuit is used to generate high frequency oscillating current signals with different frequencies and amplitudes, which flow through the common source inductance of the device under test to generate voltage signals. The common source inductance is calculated by measuring the voltage and current signals on the common source inductance. The accuracy of the measurement method is verified by measuring power devices in different packages.
引用
收藏
页码:5884 / 5888
页数:5
相关论文
共 50 条
  • [41] A SIMPLE METHOD FOR THE STEREOMETRIC MEASUREMENT
    Christensen, Helge
    ACTA RADIOLOGICA, 1939, 20 (02) : 137 - 146
  • [42] SIMPLE METHOD FOR THE MEASUREMENT OF ANTIOXIDANTS
    NOVAK, Z
    VARGA, SI
    PATAKI, L
    MATKOVICS, B
    CLINICA CHIMICA ACTA, 1990, 194 (2-3) : 115 - 120
  • [43] A SIMPLE METHOD FOR THE MEASUREMENT OF TURBIDITY
    JULLANDER, I
    ACTA CHEMICA SCANDINAVICA, 1949, 3 (10): : 1309 - 1317
  • [44] A Simple and Accurate Leakage Inductance Adjustment Method for Medium Frequency Transformer
    Guo, Xuan
    Li, Chi
    Zheng, Zedong
    Li, Yongdong
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 5501 - 5506
  • [45] Simple method for measuring the equivalent series inductance and resistance of electrolytic capacitors
    Tsang, K. M.
    Chan, W. L.
    IET POWER ELECTRONICS, 2010, 3 (04) : 465 - 471
  • [46] SIMPLE MODE-LOCKING METHOD WITH APPLICATIONS IN THE OPTOELECTRONICS DEVICES RESPONSE-TIME MEASUREMENT
    PODOLEANU, AG
    POPESCU, IM
    STERIAN, PE
    REVUE DE PHYSIQUE APPLIQUEE, 1986, 21 (04): : 277 - 282
  • [47] A New Gate Drive Technique for Superjunction MOSFETs to Compensate the Effects of Common Source Inductance
    Zojer, Bernhard
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 2763 - 2768
  • [48] Parasitic Inductance Network Modeling Method for Power Module Inner Wirings Based on Inductance Matrix Measurement
    Kobashi, Kotaro
    Umetani, Kazuhiro
    Ishihara, Masataka
    Sakai, Hiroto
    Okawauchi, Yuta
    Hayashi, Takuto
    Hiraki, Eiji
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 2530 - 2536
  • [49] SIMPLE SOURCE FOR A DIRECT MEASUREMENT OF COHERENCE LENGTH
    DIORIO, M
    FORTIN, E
    PICHE, M
    AMERICAN JOURNAL OF PHYSICS, 1975, 43 (10) : 927 - 928
  • [50] Simple clinical method of average intima-media thickness measurement in the common carotid artery
    Csanyi, A
    Egervari, A
    VASA-JOURNAL OF VASCULAR DISEASES, 1996, 25 (03): : 242 - 248