Effect of central corneal thickness on Goldmann applanation tonometry measures - a different result with different pachymeters

被引:16
|
作者
Doughty, Michael J. [1 ]
Jonuscheit, Sven [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
关键词
central corneal thickness; ultrasound pachymetry; orbscan; Goldmann tonometry; normal corneas;
D O I
10.1007/s00417-007-0601-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess whether the use of Orbscan pachymetry, as an alternative to ultrasound pachymetry, had an effect on the IOP-CCT relationship for Goldmann tonometry in normal human eyes. The right eye of 50 healthy subjects, aged 19 to 82 years, were assessed by Orbscan (three scans), and then central corneal thickness (CCT) measured by ultrasound pachymetry (three readings) and Goldmann tonometry performed (three readings). Goldmann tonometry indicated average IOP values from 9.7 to 20 mm Hg (group mean 14.3 +/- 2.5 mm Hg) that were highly highly correlated with ultrasound pachymetry (r=0.608, p < 0.001). Orbscan central zone pachymetry (2-mm sample zone) yielded higher values than ultrasound, averaging 0.591 +/- 0.044 mm compared to 0.523 +/- 0.037 mm (p < 0.001), with the differences between the instruments being proportional to the average thickness (p < 0.001; r=0.461). Notwithstanding, the Goldmann tonometry values were still highly correlated with the Orbscan central zone thickness data (r=0.595, p < 0.001); but, due to the difference in the thickness data generated by the two pachymeters, the absolute slope of the IOP-CCT relationship was slightly less if Orbscan measures were used, with or without use of the acoustic factor. Orbscan measures of the thickness of a central corneal zone can be used to assess the impact of central corneal thickness on Goldmann tonometry data.
引用
收藏
页码:1603 / 1610
页数:8
相关论文
共 50 条
  • [41] The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods
    Lubbad, Ahmed
    Oluwatoba-Popoola, Irene
    Haar, Melanie
    Framme, Carsten
    Bajor, Anna
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (07) : 2167 - 2174
  • [42] The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
    Tonnu, PA
    Ho, T
    Newson, T
    El Sheikh, A
    Sharma, K
    White, E
    Bunce, C
    Garway-Heath, D
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (07) : 851 - 854
  • [43] The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements
    Hamilton, Kirsten E.
    Pye, David C.
    Hali, Amir
    Lin, Cassie
    Kam, Phillip
    Ngyuen, Trinh
    JOURNAL OF GLAUCOMA, 2007, 16 (01) : 153 - 158
  • [44] Influence of Corneal Thickness Changes during Active Uveitis on Goldmann Applanation and Dynamic Contour Tonometry
    Heinz, Carsten
    Taneri, Suphi
    Roesel, Martin
    Heiligenhaus, Arnd
    OPHTHALMIC RESEARCH, 2012, 48 (01) : 38 - 42
  • [45] Errors of Goldmann applanation tonometry following corneal Lasik surgery
    Langham, ME
    O'Brien, TP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S496 - S496
  • [46] Goldmann applanation tonometry after Intacs corneal ring segments
    Ruckhofer, J
    Linebarger, EJ
    Schanzlin, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1332 - 1338
  • [47] Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonomet
    Francis, Brian A.
    Hsieh, Amy
    Lai, Mei-Ying
    Chopra, Vikas
    Pena, Fernando
    Azen, Stanley
    Varma, Rohit
    OPHTHALMOLOGY, 2007, 114 (01) : 20 - 26
  • [48] The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry
    Oh, Jong-Hyun
    Yoo, Chungkwon
    Kim, Yong Yeon
    Kim, Hyo-Myung
    Song, Jong-Suk
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (03) : 371 - 375
  • [49] Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, Ocular Response Analyzer, and Goldmann tonometry in glaucomatous eyes
    Annette, Hager
    Kristina, Loge
    Bernd, Schroeder
    Mark-Oliver, Fuellhas
    Wolfgang, Wiegand
    JOURNAL OF GLAUCOMA, 2008, 17 (05) : 361 - 365
  • [50] Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry
    Martinez-de-la-Casa, Jose M.
    Garcia-Feijoo, Julian
    Vico, Eva
    Fernandez-Vidal, Ana
    del Castillo, Jose M. Benitez
    Wasfi, Mohamed
    Garcia-Sanchez, J.
    OPHTHALMOLOGY, 2006, 113 (12) : 2156 - 2162