Effect of central corneal thickness on Goldmann applanation tonometry measures - a different result with different pachymeters

被引:16
|
作者
Doughty, Michael J. [1 ]
Jonuscheit, Sven [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
关键词
central corneal thickness; ultrasound pachymetry; orbscan; Goldmann tonometry; normal corneas;
D O I
10.1007/s00417-007-0601-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess whether the use of Orbscan pachymetry, as an alternative to ultrasound pachymetry, had an effect on the IOP-CCT relationship for Goldmann tonometry in normal human eyes. The right eye of 50 healthy subjects, aged 19 to 82 years, were assessed by Orbscan (three scans), and then central corneal thickness (CCT) measured by ultrasound pachymetry (three readings) and Goldmann tonometry performed (three readings). Goldmann tonometry indicated average IOP values from 9.7 to 20 mm Hg (group mean 14.3 +/- 2.5 mm Hg) that were highly highly correlated with ultrasound pachymetry (r=0.608, p < 0.001). Orbscan central zone pachymetry (2-mm sample zone) yielded higher values than ultrasound, averaging 0.591 +/- 0.044 mm compared to 0.523 +/- 0.037 mm (p < 0.001), with the differences between the instruments being proportional to the average thickness (p < 0.001; r=0.461). Notwithstanding, the Goldmann tonometry values were still highly correlated with the Orbscan central zone thickness data (r=0.595, p < 0.001); but, due to the difference in the thickness data generated by the two pachymeters, the absolute slope of the IOP-CCT relationship was slightly less if Orbscan measures were used, with or without use of the acoustic factor. Orbscan measures of the thickness of a central corneal zone can be used to assess the impact of central corneal thickness on Goldmann tonometry data.
引用
收藏
页码:1603 / 1610
页数:8
相关论文
共 50 条
  • [1] Effect of central corneal thickness on Goldmann applanation tonometry measures—a different result with different pachymeters
    Michael J. Doughty
    Sven Jonuscheit
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1603 - 1610
  • [2] Correction factors for central corneal thickness in Goldmann applanation tonometry
    Kutschan, A.
    Schroeder, B.
    Hager, A.
    Dave, H.
    Wegscheider, K.
    Wiegand, W.
    OPHTHALMOLOGE, 2010, 107 (01): : 30 - 35
  • [3] Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness
    Iliev, M. E.
    Goldblum, D.
    Katsoulis, K.
    Amstutz, C.
    Frueh, B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (07) : 833 - 835
  • [4] Central corneal thickness changes after Goldmann applanation tonometry and gonioscopy
    Evangelista, JA
    Oakman, JH
    Johnson, DL
    Tao, JP
    Trespalacios, R
    Hitch, AD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Correlation Between Goldmann Applanation Tonometry and Rebound Tonometry in Relation to Central Corneal Thickness
    Brandtner, H.
    Hitzl, W.
    Strohmaier, C.
    Abri, S.
    Wintersteller, C.
    Hohensinn, M.
    Ruckhofer, J.
    Stoiber, J.
    Grabner, G.
    Reitsamer, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Effect of corneal thickness, curvature and axial length on Goldmann applanation tonometry
    Pillunat, LE
    Kohlhaas, M
    Boehm, AG
    Puersten, A
    Spoerl, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U476 - U476
  • [7] Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature
    Andreanos, Konstantinos
    Koutsandrea, Chryssanthi
    Papaconstantinou, Dimitris
    Diagourtas, Andreas
    Kotoulas, Andreas
    Dimitrakas, Panagiotis
    Moschos, Marilita M.
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 2477 - 2484
  • [8] Central corneal thickness and applanation tonometry
    Huang, Yuqiang
    Tham, Clement C. Y.
    Zhang, Mingzhi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 347 - 347
  • [9] APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
    EHLERS, N
    BRAMSEN, T
    SPERLING, S
    ACTA OPHTHALMOLOGICA, 1975, 53 (01): : 34 - 43
  • [10] Effect of central corneal thickness on dynamic contour tonometry and goldmann applanation tonometry in primary open-angle glaucoma
    Grieshaber, Matthias C.
    Schoetzau, Andreas
    Zawinka, Claudia
    Flammer, Josef
    Orgul, Selim
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (06) : 740 - 744