Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment

被引:191
|
作者
Wilkoff, Bruce L. [1 ]
Bello, David [2 ]
Taborsky, Milos [3 ]
Vymazal, Josef [3 ]
Kanal, Emanuel [4 ]
Heuer, Hubertus [5 ]
Hecking, Katrin [5 ]
Ben Johnson, W. [6 ]
Young, William [6 ]
Ramza, Brian [7 ]
Akhtar, Naveed [7 ]
Kuepper, Bernhard [8 ]
Hunold, Peter [8 ]
Luechinger, Roger [9 ,10 ]
Puererfellner, Helmut [11 ]
Duru, Firat [12 ]
Gotte, M. J. W. [13 ]
Sutton, Richard [14 ]
Sommer, Torsten [15 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Orlando Reg Med Ctr Inc, Orlando, FL USA
[3] Na Homoice Hosp, Prague, Czech Republic
[4] UPMC Presbyterian, Pittsburgh, PA USA
[5] St Johannes Hosp, Dortmund, Germany
[6] Mercy Hosp, Iowa Heart Ctr PC, Des Moines, IA USA
[7] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[8] Elisabeth Hosp, Essen, Germany
[9] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[10] ETH, Zurich, Switzerland
[11] Ao Krankenhaus Elisabethinen, Linz, Austria
[12] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[13] HAGA Ziekenhuis, Locatie Leyweg, Den Haag, Netherlands
[14] St Marys Hosp, London, England
[15] Univ Bonn, Acad Hosp, German Red Cross Hosp DRK Neuwied, Neuwied, Germany
关键词
Bradycardia pacing; CapSureFixMRI; EnRhythmMRI; MRI; Pacemaker; RevoMRI; Safety; SureScan; RADIOFREQUENCY POWER DEPOSITION; CARDIAC-PACEMAKERS; IN-VITRO; COMPLICATIONS; IMPLANTATION; TESLA; LEADS; SAFE;
D O I
10.1016/j.hrthm.2010.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Magnetic resonance imaging (MRI) of pacemaker patients is contraindicated due to documented potential risks to the patient from hazardous interactions between the MRI and pacemaker system. OBJECTIVE The purpose of this prospective, randomized, controlled, worldwide clinical trial was to evaluate the safety and effectiveness of a pacemaker system designed for safe use in MRI for any bradycardia indicated patient. METHODS Patients (n = 464) were randomized to undergo an MRI scan between 9 and 12 weeks postimplant (MRI group, n = 258) or not to undergo MRI (control group, n = 206) after successful implantation of the specially designed dual`-chamber pacemaker and leads. Patients were monitored for arrhythmias, symptoms, and pacemaker system function during 14 nonclinically indicated relevant brain and lumbar MRI sequences. Sequences were performed at 1.5 T and included scans with high radiofrequency power deposition and/or high gradient dB/dt exposure. Clinical evaluation of the pacemaker system function occurred immediately before and after MRI, 1 week and 1 month post`-MRI, and at corresponding times for the control group. Primary endpoints for safety analyzed the MRI procedure complication-free rate and for effectiveness compared capture and sensing performance between MRI and control groups. RESULTS No MRI-related complications occurred during or after MRI, including sustained ventricular arrhythmias, pacemaker inhibition or output failures, electrical resets, or other pacemaker malfunctions. Pacing capture threshold and sensed electrogram amplitude changes were minimal and similar between study groups. CONCLUSION This trial documented the ability of this pacemaker system to be exposed in a controlled fashion to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [31] A desktop magnetic resonance imaging system
    Steven M. Wright
    David G. Brown
    Jay R. Porter
    David C. Spence
    Emilio Esparza
    David C. Cole
    F. Russell Huson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 13 (3) : 177 - 185
  • [32] NUCLEAR MAGNETIC-RESONANCE IMAGING IN A PATIENT WITH A DDR PACEMAKER
    SHAMMASH, JB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (04): : 620 - 620
  • [33] Cardiovascular Magnetic Resonance Imaging in a Patient With Implanted Leadless Pacemaker
    Lobe, Susanne
    Hilbert, Sebastian
    Hindricks, Gerhard
    Jahnke, Cosima
    Paetsch, Ingo
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (01) : 149 - 150
  • [34] Magnetic resonance imaging in a patient with a dual-chamber pacemaker
    Garcia-Bolao, I
    Albaladejo, V
    Benito, A
    Alegria, E
    Zubieta, JL
    ACTA CARDIOLOGICA, 1998, 53 (01) : 33 - 35
  • [35] In vivo heating of pacemaker leads during magnetic resonance imaging
    Luechinger, R
    Zeijlemaker, VA
    Pedersen, EM
    Mortensen, P
    Falk, E
    Duru, F
    Candinas, R
    Boesiger, P
    EUROPEAN HEART JOURNAL, 2005, 26 (04) : 376 - 383
  • [36] Pacemaker safety during magnetic resonance imaging at 1.5 Tesla
    Coman, JA
    Martin, ET
    Ramza, BM
    Margolis, PD
    Fair, RD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 436A - 436A
  • [37] NUCLEAR MAGNETIC-RESONANCE IMAGING IN A PATIENT WITH A DDD PACEMAKER
    ALAGONA, P
    TOOLE, JC
    MANISCALCO, BS
    GLOVER, MU
    ABERNATHY, GT
    PRIDA, XE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (04): : 619 - 619
  • [38] Magnetic resonance imaging is uncomfortable for patients
    Sheldon, KJ
    BRITISH MEDICAL JOURNAL, 1996, 313 (7061): : 885 - 885
  • [39] Magnetic resonance imaging of patients with epilepsy
    Connor, SEJ
    Jarosz, JM
    CLINICAL RADIOLOGY, 2001, 56 (10) : 787 - 801
  • [40] Magnetic resonance imaging and magnetic resonance spectroscopy in dementias
    Hsu, YY
    Du, AT
    Schuff, N
    Weiner, MW
    JOURNAL OF GERIATRIC PSYCHIATRY AND NEUROLOGY, 2001, 14 (03) : 145 - 166