Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment

被引:191
|
作者
Wilkoff, Bruce L. [1 ]
Bello, David [2 ]
Taborsky, Milos [3 ]
Vymazal, Josef [3 ]
Kanal, Emanuel [4 ]
Heuer, Hubertus [5 ]
Hecking, Katrin [5 ]
Ben Johnson, W. [6 ]
Young, William [6 ]
Ramza, Brian [7 ]
Akhtar, Naveed [7 ]
Kuepper, Bernhard [8 ]
Hunold, Peter [8 ]
Luechinger, Roger [9 ,10 ]
Puererfellner, Helmut [11 ]
Duru, Firat [12 ]
Gotte, M. J. W. [13 ]
Sutton, Richard [14 ]
Sommer, Torsten [15 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Orlando Reg Med Ctr Inc, Orlando, FL USA
[3] Na Homoice Hosp, Prague, Czech Republic
[4] UPMC Presbyterian, Pittsburgh, PA USA
[5] St Johannes Hosp, Dortmund, Germany
[6] Mercy Hosp, Iowa Heart Ctr PC, Des Moines, IA USA
[7] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[8] Elisabeth Hosp, Essen, Germany
[9] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[10] ETH, Zurich, Switzerland
[11] Ao Krankenhaus Elisabethinen, Linz, Austria
[12] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[13] HAGA Ziekenhuis, Locatie Leyweg, Den Haag, Netherlands
[14] St Marys Hosp, London, England
[15] Univ Bonn, Acad Hosp, German Red Cross Hosp DRK Neuwied, Neuwied, Germany
关键词
Bradycardia pacing; CapSureFixMRI; EnRhythmMRI; MRI; Pacemaker; RevoMRI; Safety; SureScan; RADIOFREQUENCY POWER DEPOSITION; CARDIAC-PACEMAKERS; IN-VITRO; COMPLICATIONS; IMPLANTATION; TESLA; LEADS; SAFE;
D O I
10.1016/j.hrthm.2010.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Magnetic resonance imaging (MRI) of pacemaker patients is contraindicated due to documented potential risks to the patient from hazardous interactions between the MRI and pacemaker system. OBJECTIVE The purpose of this prospective, randomized, controlled, worldwide clinical trial was to evaluate the safety and effectiveness of a pacemaker system designed for safe use in MRI for any bradycardia indicated patient. METHODS Patients (n = 464) were randomized to undergo an MRI scan between 9 and 12 weeks postimplant (MRI group, n = 258) or not to undergo MRI (control group, n = 206) after successful implantation of the specially designed dual`-chamber pacemaker and leads. Patients were monitored for arrhythmias, symptoms, and pacemaker system function during 14 nonclinically indicated relevant brain and lumbar MRI sequences. Sequences were performed at 1.5 T and included scans with high radiofrequency power deposition and/or high gradient dB/dt exposure. Clinical evaluation of the pacemaker system function occurred immediately before and after MRI, 1 week and 1 month post`-MRI, and at corresponding times for the control group. Primary endpoints for safety analyzed the MRI procedure complication-free rate and for effectiveness compared capture and sensing performance between MRI and control groups. RESULTS No MRI-related complications occurred during or after MRI, including sustained ventricular arrhythmias, pacemaker inhibition or output failures, electrical resets, or other pacemaker malfunctions. Pacing capture threshold and sensed electrogram amplitude changes were minimal and similar between study groups. CONCLUSION This trial documented the ability of this pacemaker system to be exposed in a controlled fashion to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [21] Low-field magnetic resonance imaging: increased safety for pacemaker patients?
    Strach, Katharina
    Naehle, Claas Philip
    Muehlsteffen, Artur
    Hinz, Michael
    Bernstein, Adam
    Thomas, Daniel
    Linhart, Markus
    Meyer, Carsten
    Bitaraf, Sascha
    Schild, Hans
    Sommer, Torsten
    EUROPACE, 2010, 12 (07): : 952 - 960
  • [22] Potential harmful effects of magnetic resonance imaging in pacemaker patients should not be underestimated
    Luechinger, R
    Zeijlemaker, VA
    Boesiger, P
    Duru, F
    EUROPACE, 2006, 8 (05): : 389 - 390
  • [23] Safety and Outcomes of Magnetic Resonance Imaging in Patients With Abandoned Pacemaker and Defibrillator Leads
    Higgins, John V.
    Gard, Joseph J.
    Espinosa, Raul E.
    Sheldon, Seth H.
    Asirvatham, Samuel I.
    Acker, Nancy
    Dalzell, Connie
    Cha, Yong-Mei
    Felmlee, Joel P.
    Wood, Christopher P.
    Watson, Robert E.
    Friedman, Paul A.
    CIRCULATION, 2013, 128 (22)
  • [24] The real-world need for magnetic resonance imaging in patients with implanted pacemaker
    Radovanovic, N.
    Kircanski, B.
    Pavlovic, S. U.
    Nikcevic, G.
    Zivkovic, M.
    Jovanovic, V.
    Milasinovic, A.
    Milasinovic, G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 251 - 251
  • [25] ASSESSMENT OF DIAGNOSTIC NEED FOR MAGNETIC RESONANCE IMAGING IN MEDICARE PATIENTS WITH PACEMAKER IMPLANTS
    Eggleston, A.
    Lim, M.
    Veath, B. K.
    Mura, T.
    VALUE IN HEALTH, 2012, 15 (07) : A611 - A611
  • [26] Instrument visualization in a magnetic resonance imaging environment
    Ladd, ME
    Debatin, JF
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1999, 16 (01) : 13 - 21
  • [27] Magnetic resonance imaging of the musculoskeletal system
    Siegel, S
    White, LM
    Brahme, S
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (332) : 281 - 300
  • [28] A desktop magnetic resonance imaging system
    Wright, SM
    Brown, DG
    Porter, JR
    Spence, DC
    Esparza, E
    Cole, DC
    Huson, FR
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03): : 177 - 185
  • [29] Heating of pacemaker leads during magnetic resonance imaging: reply
    Luechinger, R
    Zeijlemaker, VA
    Duru, F
    Boesiger, P
    EUROPEAN HEART JOURNAL, 2005, 26 (12) : 1243 - 1244
  • [30] Magnetic resonance imaging-based biventricular pacemaker upgrade
    Róka, A
    Simor, T
    Vágó, SH
    Minorics, C
    Acsády, G
    Merkely, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (07): : 1011 - 1013