Performance analysis on an air-conditioning system installed with and without a fuzzy logic thermostat in an office building

被引:3
|
作者
Yau, Y. H. [1 ]
Chang, C. P. [1 ,2 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur, Malaysia
[2] IGB Corp Ltd, Level 32,Gardens South Tower, Kuala Lumpur, Malaysia
关键词
Fuzzy logic; thermostat setting; thermal comfort; cooling demand; TRNSYS; THERMAL COMFORT; CLIMATE-CHANGE; ENERGY; MANAGEMENT;
D O I
10.1177/0957650918762022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current research presents the study of the proposed thermostat setting developed in the previous work through a numerical simulation project using transient system simulation tool. The transient system simulation tool code is used to integrate the fuzzy logic to optimise a room thermostat with the multi-zone building model (Type56a). A set of equations is designed in the transient system simulation tool project to represent the fuzzy logic control system of the proposed thermostat setting. The performance analysis for the air-conditioning system installed with and without the application of the control system in terms of the operative zone temperature, the sensible cooling demand, the solar radiation, and the internal gains for a thermal zone for recent years or 2000s, and for the years 2020, 2050 and 2080 were comprehensively examined. Estimations of both predicted mean vote and predicted percentage of dissatisfied persons of the zone were also investigated. The findings indicate that a considerable amount of sensible cooling demand of approximately 8420 kJ/h or equivalent to 3.54% can be saved with the application of the proposed thermostat setting. The predicted mean vote is in the range from -0.22 to 0.72 with its average between 0.20 and 0.26 for the AC system installed with fuzzy logic control. These results further suggest that the thermal comfort of occupants can be improved taking into account their activity level, clothing insulation, indoor air temperature, air velocity, mean radiant temperature and relative humidity.
引用
收藏
页码:1079 / 1092
页数:14
相关论文
共 50 条
  • [41] RESEARCH ON BODY THERMAL SENSATIONS OF MAN DURING AIR-CONDITIONING IN AN OFFICE BUILDING
    NARUSE, T
    KAJII, H
    SAITOH, K
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1978, 22 (04) : 330 - 330
  • [42] Utilising Neutrosophic Logic in the Design of a Smart Air-Conditioning System
    Karunakaran, Hemalatha
    Bhumireddy, Venkateswarlu
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [43] Energy analysis for air conditioning system using fuzzy logic controller
    Nasution H.
    Jamaluddin H.
    Syeriff J.M.
    Telkomnika, 2011, 9 (01): : 139 - 150
  • [44] Performance and Energy Analysis of a Solar Hybrid Desiccant Air-Conditioning System
    Enggsa, Zuraini Mohd
    Rachman, Arfidian
    Sulaiman, Yusof
    Asmidzam, M.
    Mat, Sohif
    Sopian, Kamaruzzaman
    INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2015 (ISCPMS 2015), 2016, 1729
  • [45] MEASURED AIR-CONDITIONING AND THERMAL PERFORMANCE OF A THAI RESIDENTIAL BUILDING
    PARKER, DS
    ENERGY, 1995, 20 (09) : 907 - 914
  • [46] Performance analysis of the air-conditioning system in Xi'an Xianyang International Airport
    Zhang, Tao
    Liu, Xiaohua
    Zhang, Lun
    Jiang, Jingjing
    Zhou, Min
    Jiang, Yi
    ENERGY AND BUILDINGS, 2013, 59 : 11 - 20
  • [47] Performance and characteristic analysis of a super efficient hybrid air-conditioning system
    Jeong, JS
    Hyun, SG
    Saito, K
    Kawai, S
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 246 - 254
  • [48] Performance evaluation of centrifugal chillers in an air-conditioning plant with the building automation system (BAS)
    Ng, K.C.
    Bong, T.Y.
    Chua, H.T.
    Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 1994, 208 (04) : 249 - 255
  • [49] PERFORMANCE EVALUATION OF CENTRIFUGAL CHILLERS IN AN AIR-CONDITIONING PLANT WITH THE BUILDING AUTOMATION SYSTEM (BAS)
    NG, KC
    BONG, TY
    CHUA, HT
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1994, 208 (A4) : 249 - 255
  • [50] Field study and numerical investigation on heating performance of air carrying energy radiant air-conditioning system in an office
    Peng, Pei
    Gong, Guangcai
    Deng, Xiaorui
    Liang, Chun
    Li, Wenqiang
    ENERGY AND BUILDINGS, 2020, 209