Performance analysis on an air-conditioning system installed with and without a fuzzy logic thermostat in an office building

被引:3
|
作者
Yau, Y. H. [1 ]
Chang, C. P. [1 ,2 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur, Malaysia
[2] IGB Corp Ltd, Level 32,Gardens South Tower, Kuala Lumpur, Malaysia
关键词
Fuzzy logic; thermostat setting; thermal comfort; cooling demand; TRNSYS; THERMAL COMFORT; CLIMATE-CHANGE; ENERGY; MANAGEMENT;
D O I
10.1177/0957650918762022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current research presents the study of the proposed thermostat setting developed in the previous work through a numerical simulation project using transient system simulation tool. The transient system simulation tool code is used to integrate the fuzzy logic to optimise a room thermostat with the multi-zone building model (Type56a). A set of equations is designed in the transient system simulation tool project to represent the fuzzy logic control system of the proposed thermostat setting. The performance analysis for the air-conditioning system installed with and without the application of the control system in terms of the operative zone temperature, the sensible cooling demand, the solar radiation, and the internal gains for a thermal zone for recent years or 2000s, and for the years 2020, 2050 and 2080 were comprehensively examined. Estimations of both predicted mean vote and predicted percentage of dissatisfied persons of the zone were also investigated. The findings indicate that a considerable amount of sensible cooling demand of approximately 8420 kJ/h or equivalent to 3.54% can be saved with the application of the proposed thermostat setting. The predicted mean vote is in the range from -0.22 to 0.72 with its average between 0.20 and 0.26 for the AC system installed with fuzzy logic control. These results further suggest that the thermal comfort of occupants can be improved taking into account their activity level, clothing insulation, indoor air temperature, air velocity, mean radiant temperature and relative humidity.
引用
收藏
页码:1079 / 1092
页数:14
相关论文
共 50 条
  • [21] Simulation Analysis of System Partition in Office Building Air Conditioning System
    Yu, Yu
    Li, Hui
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3686 - 3691
  • [23] Experimental Analysis of Energy Efficient Building Air Conditioning System Using Fuzzy Logic Controller
    Karunakaran, R.
    Parameshwaran, R.
    Senthilkumar, A.
    Iniyan, S.
    INTERNATIONAL ENERGY JOURNAL, 2009, 10 (02): : 113 - 130
  • [24] Performance Analysis of an Integrated Heat Pump with Air-Conditioning System for the Existing Hospital Building Application
    Chiang, Chen-Yu
    Yang, Ru
    Yang, Kuan-Hsiung
    Lee, Shin-Ku
    SUSTAINABILITY, 2017, 9 (04):
  • [25] Facility performance evaluation to develop heating, ventilation, and air-conditioning system design and operation strategies for an office building in Mongolia
    Rhee, Kyu-Nam
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (08) : 1209 - 1225
  • [26] Genetic-algorithm-optimized fuzzy logic control of a variable air volume air-conditioning system
    Huang, Yonghong
    Li, Nianping
    Yu, Tao
    Shi, Yangchun
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 2643 - 2647
  • [27] Improved energy performance of air-conditioning system using variable primary flow chilled water systems in an office building
    Sung, Wen-Pei
    Tsai, Tzai-Tang
    Wang, Hsien-Jung
    Chen, Ming Der
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 1973 - +
  • [28] The choice of air conditioning system for office building
    Zhao, JC
    Li, BT
    Umin, ZX
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 823 - 828
  • [29] Experimental Research on the Formaldehyde Diffusion Performance in an Air-conditioning Office
    Zhang, Changxing
    Hu, Songtao
    Wang, Gang
    2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 3, PROCEEDINGS, 2009, : 48 - 51
  • [30] Performance analysis of a membrane liquid desiccant air-conditioning system
    Abdel-Salam, Ahmed H.
    Ge, Gaoming
    Simonson, Carey J.
    ENERGY AND BUILDINGS, 2013, 62 : 559 - 569