A selective voltammetric method for uric acid detection at Nafion®-coated carbon paste electrodes

被引:72
|
作者
Zen, JM [1 ]
Hsu, CT [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
carbon paste electrode; Nafion (R); uric acid;
D O I
10.1016/S0039-9140(98)00004-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A square-wave voltammetric method together with Nafion(R)-coated carbon paste electrodes were used for the selective determination of uric acid in the presence of a high concentration of ascorbic acid. Since the oxidation potential of uric acid is about 200 mV more positive than that of ascorbic acid at the Nafion(R)-coated carbon paste electrode, the selectivity can be greatly improved simply by applying an electrolysis potential of + 0.4 V vs. Ag/AgCl where only ascorbic acid is oxidised. The acceptable tolerance of ascorbic acid concentration for the determination of uric acid is as high as 1.5 mM. With 30 s of electrolysis time, a linear calibration curve is obtained over the 0-50 mu M range in 0.05 hi citrate buffer solution, pH 4.0, with slope (mu A/mu M) and correlation coefficient of 0.34 and 0.9984, respectively. The detection limit (30) is 0.25 mu M. The practical analytical utility is illustrated by selective measurements of uric acid in human urine without any preliminary treatment. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1363 / 1369
页数:7
相关论文
共 50 条
  • [31] VOLTAMMETRIC DETERMINATION OF CELIPTIUM WITH CARBON PASTE AND LIPID-MODIFIED CARBON PASTE ELECTRODES
    ARCOS, J
    KAUFFMANN, JM
    PATRIARCHE, GJ
    SANCHEZBATANERO, P
    ANALYTICA CHIMICA ACTA, 1990, 236 (02) : 299 - 305
  • [32] Voltammetric study of glibenclamide at carbon paste and Sephadex-modified carbon paste electrodes
    Radi, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) : 822 - 826
  • [33] Voltammetric study of glibenclamide at carbon paste and Sephadex-modified carbon paste electrodes
    A. Radi
    Analytical and Bioanalytical Chemistry, 2004, 378 : 822 - 826
  • [34] Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Motghare, Ramani V.
    Tadi, Kiran Kumar
    Dhawale, Payal
    Deotare, Samiksha
    Kawadkar, Aruna K.
    Chillawar, Rakesh
    Khan, Shirinaz
    ELECTROANALYSIS, 2015, 27 (03) : 825 - 832
  • [35] Voltammetric investigation of uric acid in existence of dopamine at Poly(benzydamine) modified carbon paste electrode
    Sukanya
    Kumara Swamy B.E.
    Shashikumara J.K.
    Sensors International, 2020, 1
  • [36] Zinc Oxide Modified Carbon Paste Electrode Sensor for Uric Acid: A Cyclic Voltammetric Study
    Kumar, Mohan
    Swamy, Bahaddurghatta E. Kumara
    Sathisha, Tammanekar V.
    Deepa, Ramachandra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 610 - 622
  • [37] Cyclic Voltammetric and Quantum Chemical Studies of a Poly(methionine) Modified Carbon Paste Electrode for Simultaneous Detection of Dopamine and Uric Acid
    Chandrashekar, Bananakere Nanjegowda
    Lv, Weizhong
    Jayaprakash, Gururaj Kudur
    Harrath, Karim
    Liu, Louis W. Y.
    Swamy, Bahaddurghatta E. Kumara
    CHEMOSENSORS, 2019, 7 (02)
  • [38] Voltammetric determination of mefenamic acid at lanthanum hydroxide nanowires modified carbon paste electrodes
    Liu, Li
    Song, Junfeng
    ANALYTICAL BIOCHEMISTRY, 2006, 354 (01) : 22 - 27
  • [39] Selective Determination of Uric Acid, Tryptphan, and Serotonin at Glassy Carbon Paste Electrode
    Nishiyama, Katsuhiko
    Inada, Kazufumi
    Taniguchi, Isao
    ELECTROCHEMISTRY, 2010, 78 (02) : 165 - 169
  • [40] Voltammetric determination of carbidopa in the presence of uric acid and folic acid using a modified carbon nanotube paste electrode
    Rastakhiz, Nahid
    Beitollahi, Hadi
    Kariminik, Ashraf
    Karimi, Fatemeh
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 172 : 66 - 70