Biomechanical Evaluation of Modified ACL Reconstruction with Over-the-Top Augmentation Technique

被引:4
|
作者
Min, Byoung-Hyun [1 ]
Song, Hyung Keun [1 ]
Park, Ki Hoon [1 ]
Kim, Tae Hun [1 ]
Park, Do Young [1 ]
Chung, Jun Young [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Orthoped Surg, 164 Worldcup Ro, Suwon 16499, South Korea
关键词
Knee; Anterior cruciate ligament; ACL reconstruction; Triple bundle; Over-the-top; ANTERIOR CRUCIATE LIGAMENT; PIVOT-SHIFT; SINGLE-BUNDLE; PATELLAR TENDON; PORCINE KNEE; METAANALYSIS; STABILITY; MODEL;
D O I
10.1007/s43465-021-00597-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Modified ACL reconstruction with over-the-top augmentation technique (OA-ACLR) was designed to allow one-stage revision regardless of tunnel conditions as well as to offer firm stability by hybrid double-fixation. Thus, the purpose of the study is to biomechanically evaluate its effect on knee stability by comparing it with single-bundle ACL reconstruction (SB-ACLR). Methods Ten porcine knees were sequentially tested using a custom testing system for intact ACL, ACL deficiency, SB-ACLR and OA-ACLR. First, 134-N anterior tibial load was applied, and anterior tibial translation was measured at 30 degrees, 60 degrees, and 90 degrees. Then, anterior tibial translation and relative tibial rotation were measured in a combined rotatory load of 5-Nm of internal tibial torque and 10-Nm of valgus torque. Results Under anterior tibial load or combined anterior and rotatory loads, SB-ACLR and OA-ACLR resulted in no significant increase in anterior tibial translation at all flexion angles compared with an intact ACL group, and no significant difference was noted in anterior tibial translation between the two ACL reconstruction groups. In combined rotatory load, OA-ACLR resulted in enhanced rotational stability compared with SB-ACLR, and it more closely restored relative tibial internal rotation to the intact ACL group. Conclusions Our study showed that modified ACL reconstruction with over-the-top augmentation technique resulted in enhanced rotational stability compared to the conventional single-bundle ACL reconstruction, especially at lower flexion angle in a porcine model. Therefore, with several potential advantages as well as biomechanical superiority, our new technique could be clinically applicable in primary and revision ACL reconstruction.
引用
收藏
页码:812 / 820
页数:9
相关论文
共 50 条
  • [31] Over-the-top ACL Reconstruction Plus Extra-articular Lateral Tenodesis With Hamstring Tendon Grafts Prospective Evaluation With 20-Year Minimum Follow-up
    Zaffagnini, Stefano
    Muccioli, Giulio Maria Marcheggiani
    Grassi, Alberto
    di Sarsina, Tommaso Roberti
    Raggi, Federico
    Signorelli, Cecilia
    Urrizola, Francisco
    Spinnato, Paolo
    Rimondi, Eugenio
    Marcacci, Maurilio
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2017, 45 (14): : 3233 - 3242
  • [32] Modified MacIntosh (Over-the-Top Iliotibial Band Autograft) Technique for Pediatric Anterior Cruciate Ligament Reconstruction Using Knotless All-Suture Anchor Fixation
    Richards, Jarod A.
    Mays, Logan M.
    Woodard, David R.
    Defroda, Steven F.
    Nuelle, Clayton W.
    ARTHROSCOPY TECHNIQUES, 2025, 14 (02):
  • [33] Equivalent outcomes of ACL revision with over-the-top single and double-bundle reconstruction using hamstring tendon compared to anatomical single and double-bundle reconstruction
    Kamei, Goki
    Nakamae, Atsuo
    Ishikawa, Masakazu
    Nakata, Kyohei
    Nekomoto, Akinori
    Tsuji, Shunya
    Hashiguchi, Naofumi
    Adachi, Nobuo
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [34] Over-The-Top Knot Placement Technique Enhances Tensile Stability of Tendon Repairs
    Turker, Mehmet
    Cetik, Ozgur
    Kilicoglu, Onder
    Cirpar, Meric
    Dirikolu, Husnu
    Kalaycioglu, Baris
    Ozturk, Latif
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (11) : 1006 - 1013
  • [35] Evaluation of hollow mesh augmentation on the biomechanical properties of the flexor tendon repaired with modified Kessler technique
    Liu, Haoyu
    Thoreson, Andrew
    Kadar, Assaf
    Moran, Steven
    Zhao, Chunfeng
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 20 : 80 - 85
  • [36] ANTERIOR CRUCIATE RECONSTRUCTION USING THE MACINTOSH LATERAL-SUBSTITUTION OVER-THE-TOP REPAIR
    BERTOIA, JT
    UROVITZ, EP
    RICHARDS, RR
    GROSS, AE
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08): : 1183 - 1188
  • [37] Anatomic Anterior Cruciate Ligament Reconstruction Using the Over-the-Top Passage of Hamstring Tendons
    Marcacci, Maurillo
    Zaffagnini, Stefano
    Marchesini, Leonardo
    Delcogliano, Marco
    Bruni, Danilo
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2005, 15 (02) : 123 - 129
  • [38] ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BY OVER-THE-TOP REPAIR COMBINED WITH POPLITEUS TENDON PLASTY
    MITSOU, A
    VALLIANATOS, P
    PISKOPAKIS, N
    MAHERAS, S
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03): : 398 - 404
  • [39] 7 YEARS EXPERIENCE WITH A MODIFIED OVER-THE-TOP CRUCIAL LIGAMENT PLASTIC OPERATION IN DOG
    BRUNNBERG, L
    RIEGER, I
    HESSE, EM
    KLEINTIERPRAXIS, 1992, 37 (11): : 735 - &
  • [40] The 25-year experience of over-the-top ACL reconstruction plus extra-articular lateral tenodesis with hamstring tendon grafts: the story so far
    Stefano Zaffagnini
    Gian Andrea Lucidi
    Luca Macchiarola
    Piero Agostinone
    Maria Pia Neri
    Maurilio Marcacci
    Alberto Grassi
    Journal of Experimental Orthopaedics, 10