Biomechanical Evaluation of Modified ACL Reconstruction with Over-the-Top Augmentation Technique

被引:4
|
作者
Min, Byoung-Hyun [1 ]
Song, Hyung Keun [1 ]
Park, Ki Hoon [1 ]
Kim, Tae Hun [1 ]
Park, Do Young [1 ]
Chung, Jun Young [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Orthoped Surg, 164 Worldcup Ro, Suwon 16499, South Korea
关键词
Knee; Anterior cruciate ligament; ACL reconstruction; Triple bundle; Over-the-top; ANTERIOR CRUCIATE LIGAMENT; PIVOT-SHIFT; SINGLE-BUNDLE; PATELLAR TENDON; PORCINE KNEE; METAANALYSIS; STABILITY; MODEL;
D O I
10.1007/s43465-021-00597-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Modified ACL reconstruction with over-the-top augmentation technique (OA-ACLR) was designed to allow one-stage revision regardless of tunnel conditions as well as to offer firm stability by hybrid double-fixation. Thus, the purpose of the study is to biomechanically evaluate its effect on knee stability by comparing it with single-bundle ACL reconstruction (SB-ACLR). Methods Ten porcine knees were sequentially tested using a custom testing system for intact ACL, ACL deficiency, SB-ACLR and OA-ACLR. First, 134-N anterior tibial load was applied, and anterior tibial translation was measured at 30 degrees, 60 degrees, and 90 degrees. Then, anterior tibial translation and relative tibial rotation were measured in a combined rotatory load of 5-Nm of internal tibial torque and 10-Nm of valgus torque. Results Under anterior tibial load or combined anterior and rotatory loads, SB-ACLR and OA-ACLR resulted in no significant increase in anterior tibial translation at all flexion angles compared with an intact ACL group, and no significant difference was noted in anterior tibial translation between the two ACL reconstruction groups. In combined rotatory load, OA-ACLR resulted in enhanced rotational stability compared with SB-ACLR, and it more closely restored relative tibial internal rotation to the intact ACL group. Conclusions Our study showed that modified ACL reconstruction with over-the-top augmentation technique resulted in enhanced rotational stability compared to the conventional single-bundle ACL reconstruction, especially at lower flexion angle in a porcine model. Therefore, with several potential advantages as well as biomechanical superiority, our new technique could be clinically applicable in primary and revision ACL reconstruction.
引用
收藏
页码:812 / 820
页数:9
相关论文
共 50 条
  • [21] THE OVER-THE-TOP TECHNIQUE FOR ANTERIOR CRUCIATE LIGAMENT REPAIR IN THE DOG
    ARNOCZKY, SP
    TARVIN, GB
    KLEINTIERPRAXIS, 1980, 25 (07): : 429 - 434
  • [22] A Biomechanical Comparison of 2 Over-the-Top Anterior Cruciate Ligament Reconstruction Techniques: A Cadaveric Study Using a Robotic Simulator
    Shiwaku, Kousuke
    Suzuki, Tomoyuki
    Shino, Konsei
    Yamakawa, Satoshi
    Otsubo, Hidenori
    Okimura, Shinichiro
    Suzuki, Daisuke
    Nabeki, Shogo
    Teramoto, Atsushi
    Ohnishi, Hirofumi
    Fujie, Hiromichi
    Yamashita, Toshihiko
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (12)
  • [23] Comparing Outcomes Between the Over-the-Top and All-Epiphyseal Techniques for Physeal-Sparing ACL Reconstruction: A Narrative Review
    Wong, Stephanie E.
    Feeley, Brian T.
    Pandya, Nirav K.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (03)
  • [24] Biomechanical evaluation of an allograft fixation system for ACL reconstruction
    Benca, Emir
    van Knegsel, Kenneth P. P.
    Zderic, Ivan
    Caspar, Jan
    Strassl, Andreas
    Hirtler, Lena
    Fuchssteiner, Christoph
    Gueorguiev, Boyko
    Windhager, Reinhard
    Widhalm, Harald
    Varga, Peter
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [25] Biomechanical evaluation of PCL reconstruction with suture augmentation
    Grotting, John A.
    Nelson, Trevor J.
    Banffy, Michael B.
    Yalamanchili, Dheeraj
    Eberlein, Sam A.
    Chahla, Jorge
    Metzger, Melodie F.
    KNEE, 2020, 27 (02): : 375 - 383
  • [26] Biomechanical Comparison of Ulnar Collateral Ligament Reconstruction With a Modified Docking Technique With and Without Suture Augmentation
    Leasure, Jeremi
    Reynolds, Kerisimasi
    Thorne, Marc
    Escamilla, Rafael
    Akizuki, Ken
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (04): : 928 - 932
  • [27] Femoral Physeal-Sparing Anterior Cruciate Ligament Reconstruction Using the Iliotibial Band: Over-The-Top Technique
    Abreu, Felipe Galvao
    Pioger, Charles
    Franck, Florent
    Freychet, Benjamin
    Vieira, Thais D.
    Sonnery-Cottet, Bertrand
    ARTHROSCOPY TECHNIQUES, 2020, 9 (06): : E691 - E695
  • [28] OVER-THE-TOP PROCEDURE - TECHNIQUE FOR ANTERIOR CRUCIATE LIGAMENT SUBSTITUTION IN THE DOG
    ARNOCZKY, SP
    TARVIN, GB
    MARSHALL, JL
    SALTZMAN, B
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1979, 15 (03) : 283 - 290
  • [29] Over-the-top Anterior Cruciate Ligament (ACL) reconstruction plus lateral plasty with hamstrings in high-school athletes: Results at 10 years
    Grassi, Alberto
    Pizza, Nicola
    Macchiarola, Luca
    Lucidi, Gian Andrea
    Stefanelli, Federico
    Dal Fabbro, Giacomo
    Marcacci, Maurilio
    Zaffagnini, Stefano
    KNEE, 2021, 33 : 226 - 233
  • [30] Equivalent outcomes of ACL revision with over-the-top single and double-bundle reconstruction using hamstring tendon compared to anatomical single and double-bundle reconstruction
    Goki Kamei
    Atsuo Nakamae
    Masakazu Ishikawa
    Kyohei Nakata
    Akinori Nekomoto
    Shunya Tsuji
    Naofumi Hashiguchi
    Nobuo Adachi
    Journal of Experimental Orthopaedics, 9