Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT

被引:48
|
作者
Bauer, Ralf W. [1 ]
Kramer, Sebastian [1 ]
Renker, Matthias [1 ]
Schell, Boris [1 ]
Larson, Maya Christina [1 ]
Beeres, Martin [1 ]
Lehnert, Thomas [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Kerl, Josef Matthias [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
Dual-energy CT; 64-slice CT; Pulmonary embolism; Dose; Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ACUTE CORONARY SYNDROME; RADIATION-EXPOSURE; LUNG PERFUSION; EMBOLISM; DIAGNOSIS; FEASIBILITY; MANAGEMENT; SETTINGS; SOCIETY;
D O I
10.1007/s00330-011-2162-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). Methods Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. Results Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and > 0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 +/- 1.6 mGy/170 +/- 41 mGycm) compared to group 1 (8.5 +/- 2.6 mGy/235 +/- 117 mGycm), group 2 (9.2 +/- 3.3 mGy/224 +/- 122 mGycm) and group 3 (8.7 +/- 2.8 mGy/246 +/- 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 +/- 3 HU) and group 1 (13 +/- 6 HU) compared to group 3 and 2 (16 +/- 6 HU and 23 +/- 9). Conclusion The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 50 条
  • [21] Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT
    Tobias De Zordo
    Klemens von Lutterotti
    Christian Dejaco
    Peter F. Soegner
    Renate Frank
    Friedrich Aigner
    Andrea S. Klauser
    Christoph Pechlaner
    U. Joseph Schoepf
    Werner R. Jaschke
    Gudrun M. Feuchtner
    European Radiology, 2012, 22 : 279 - 286
  • [22] Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT
    De Zordo, Tobias
    von Lutterotti, Klemens
    Dejaco, Christian
    Soegner, Peter F.
    Frank, Renate
    Aigner, Friedrich
    Klauser, Andrea S.
    Pechlaner, Christoph
    Schoepf, U. Joseph
    Jaschke, Werner R.
    Feuchtner, Gudrun M.
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 279 - 286
  • [23] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [24] Septal Delineation using a 20% Diluted Contrast Chaser Bolus in Coronary CT Angiography: A Comparison of 64-Slice and Dual Source CT
    Wuest, W.
    Zunker, C.
    May, M.
    Anders, K.
    Ropers, D.
    Achenbach, S.
    Uder, M.
    Kuettner, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (04): : 324 - 331
  • [25] Evaluation of circle of Willis variations with 64-slice CT angiography
    Li, Qi
    Xie, Peng
    Lv, Fajin
    Luo, Tianyou
    NEUROLOGY, 2008, 70 (11) : A158 - A158
  • [26] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Pinho, Daniella F.
    Kulkarni, Naveen M.
    Krishnaraj, Arun
    Kalva, Sanjeeva P.
    Sahani, Dushyant V.
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 351 - 359
  • [27] Hemodialysis fistula occlusion - Demonstration with 64-slice CT angiography
    Neyman, EG
    Johnson, PT
    Fishman, EK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (01) : 157 - 159
  • [28] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Daniella F. Pinho
    Naveen M. Kulkarni
    Arun Krishnaraj
    Sanjeeva P. Kalva
    Dushyant V. Sahani
    European Radiology, 2013, 23 : 351 - 359
  • [29] Influence of scan protocols on radiation dose estimates for coronary 64-slice CT angiography
    Meyer, TS
    Hausleiter, J
    Huber, E
    Hadamitzky, M
    Ardelean, C
    Martinoff, S
    Schoemig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 113A - 113A
  • [30] RADIATION DOSE STUDY OF 64-SLICE SPIRAL CT CORONARY ANGIOGRAPHY: A PAIRED DESIGN
    Xie, Zhaoyong
    Wang, Jie
    Ding, Guocheng
    Song, Wei
    Xu, Ke
    Ren, Ke
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 115 - 118