A comparative study of solid and liquid inner contact paroxetine hydrochloride ion-selective electrode membranes

被引:0
|
作者
Khalil, Mohamed Magdy [1 ]
Issa, Yousry Mostfa [2 ]
Mohamed, Ali Gaber [1 ]
机构
[1] Beni Suef Univ, Fac Sci, Dept Chem, Bani Suwayf, Egypt
[2] Cairo Univ, Fac Sci, Dept Chem, Giza, Egypt
关键词
Ion-selective electrodes; Solid-contact ionselective electrode; PVC membrane electrode; Paroxetine hydrochloride; SEROTONIN REUPTAKE INHIBITORS; MASS-SPECTROMETRY; HUMAN PLASMA; POTENTIOMETRIC DETERMINATION; GAS-CHROMATOGRAPHY; ACTIVE METABOLITES; PHASE EXTRACTION; NEUTRAL CARRIER; UV DETECTION; ANTIDEPRESSANTS;
D O I
10.1007/s13738-015-0638-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A comparative study was made between two designs of paroxetine-selective electrodes: a polyvinyl chloride membrane (liquid inner contact) called electrodes PME1 and PME2 and a solid contact called electrodes CWE1 and CWE2 based on paroxetine-phosphotungstate and paroxetine-phosphomolybdate as ion exchangers. The four electrodes, PME1, PME2, CWE1 and CWE2, show linearity over the concentration range from 1 x 10(-5) to 1 x 10(-2) M, with slopes of 56.7, 54.4, 59.8 and 55.3 mV/decade, meanwhile the limits of detection were 2.5 x 10(-6), 4 x 10(-6), 5.6 x 10(-6) and 6.2 x 10(-6) M, respectively. PME1 and PME2 showed better limit of detection than electrodes CWE1 and CWE2. The present electrodes show clear discrimination of Prx.HCl from several inorganic, and organic species. The sensors were applied efficiently for determination of Prx.HCl in its pharmaceutical preparations using standard addition and the calibration curve methods.
引用
收藏
页码:1637 / 1648
页数:12
相关论文
共 50 条
  • [41] STUDY ON HYDROGEN ION-SELECTIVE SOLID CONTACT ELECTRODES BASED ON DECAMETHYLCYCLOPENTASILOXANE
    Kim, Boram
    Shim, Jihye
    Chung, Koo-Chun
    ANALYTICAL LETTERS, 2011, 44 (12) : 2138 - 2149
  • [42] Validation of the Application of Solid Contact Ion-Selective Electrode for Off-Body Sweat Ion Monitoring
    Liu, Huixin
    Gu, Zhen
    Liu, Yuan
    Xiao, Xinxin
    Xiu, Guangli
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [43] Comparative study of nitrate all solid state ion-selective electrode based on multiwalled carbon nanotubes-ionic liquid nanocomposite
    Pietrzak, Karolina
    Wardak, Cecylia
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [44] ION-EXCHANGE AT NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVATH, V
    HORVAI, G
    PUNGOR, E
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 569 - 571
  • [45] Solid-state ion-selective electrode arrays
    Lynch, A
    Diamond, D
    Lemoine, P
    McLaughlin, J
    Leader, M
    ELECTROANALYSIS, 1998, 10 (16) : 1096 - 1100
  • [46] Monitoring solid phase reactions with ion-selective electrode
    Pátek, M
    Bildstein, S
    Flegelová, Z
    TETRAHEDRON LETTERS, 1998, 39 (08) : 753 - 756
  • [47] SOLID-STATE PHOSPHATE ION-SELECTIVE ELECTRODE
    TRUXILLO, LA
    MONTALVO, JG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, 172 (SEP3): : 124 - 124
  • [48] Application of Potassium Ion Conducting KTiOPO4 as Effective Inner Solid-Contact Layer in All-Solid-State Potassium Ion-Selective Electrode
    Tatara, Ryoichi
    Ishihara, Kenta
    Kosugi, Motohiro
    Aoki, Kazuma
    Takei, Yuko
    Matsui, Takahiro
    Takayama, Toshiharu
    Komaba, Shinichi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (02)
  • [49] Equilibration Time of Solid Contact Ion-Selective Electrodes
    Guzinski, Marcin
    Jarvis, Jennifer M.
    Pendley, Bradford D.
    Lindner, Erno
    ANALYTICAL CHEMISTRY, 2015, 87 (13) : 6654 - 6659
  • [50] Ion-selective Electrode Biochip for Applications in a Liquid Environment
    Salim, W. W. A. Wan
    Hermann, A. C.
    Zietchek, M. A.
    Pfluger, J. E.
    Park, J. H.
    ul Haque, A.
    Sanober, F.
    Porterfield, D. M.
    INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 : 86 - 93