A comparative study of solid and liquid inner contact paroxetine hydrochloride ion-selective electrode membranes

被引:0
|
作者
Khalil, Mohamed Magdy [1 ]
Issa, Yousry Mostfa [2 ]
Mohamed, Ali Gaber [1 ]
机构
[1] Beni Suef Univ, Fac Sci, Dept Chem, Bani Suwayf, Egypt
[2] Cairo Univ, Fac Sci, Dept Chem, Giza, Egypt
关键词
Ion-selective electrodes; Solid-contact ionselective electrode; PVC membrane electrode; Paroxetine hydrochloride; SEROTONIN REUPTAKE INHIBITORS; MASS-SPECTROMETRY; HUMAN PLASMA; POTENTIOMETRIC DETERMINATION; GAS-CHROMATOGRAPHY; ACTIVE METABOLITES; PHASE EXTRACTION; NEUTRAL CARRIER; UV DETECTION; ANTIDEPRESSANTS;
D O I
10.1007/s13738-015-0638-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A comparative study was made between two designs of paroxetine-selective electrodes: a polyvinyl chloride membrane (liquid inner contact) called electrodes PME1 and PME2 and a solid contact called electrodes CWE1 and CWE2 based on paroxetine-phosphotungstate and paroxetine-phosphomolybdate as ion exchangers. The four electrodes, PME1, PME2, CWE1 and CWE2, show linearity over the concentration range from 1 x 10(-5) to 1 x 10(-2) M, with slopes of 56.7, 54.4, 59.8 and 55.3 mV/decade, meanwhile the limits of detection were 2.5 x 10(-6), 4 x 10(-6), 5.6 x 10(-6) and 6.2 x 10(-6) M, respectively. PME1 and PME2 showed better limit of detection than electrodes CWE1 and CWE2. The present electrodes show clear discrimination of Prx.HCl from several inorganic, and organic species. The sensors were applied efficiently for determination of Prx.HCl in its pharmaceutical preparations using standard addition and the calibration curve methods.
引用
收藏
页码:1637 / 1648
页数:12
相关论文
共 50 条
  • [21] Electrosynthesized polypyrrole/zeolite composites as solid contact in potassium ion-selective electrode
    Yu, Kai
    He, Ning
    Kumar, Narendra
    Wang, NianXing
    Bobacka, Johan
    Ivaska, Ari
    ELECTROCHIMICA ACTA, 2017, 228 : 66 - 75
  • [22] NMR-STUDY OF THE STATE OF WATER IN ION-SELECTIVE ELECTRODE MEMBRANES
    CHAN, ADC
    HARRISON, DJ
    ANALYTICAL CHEMISTRY, 1993, 65 (01) : 32 - 36
  • [23] SOLID CONTACT IN MEMBRANE ION-SELECTIVE ELECTRODES
    NIKOLSKII, BP
    MATEROVA, EA
    ION-SELECTIVE ELECTRODE REVIEWS, 1985, 7 (01): : 3 - 39
  • [24] SIMPLIFIED DESIGN FOR A LIQUID ION-SELECTIVE ELECTRODE
    GUREV, IA
    KALUGIN, AA
    GUSHCHINA, EA
    INDUSTRIAL LABORATORY, 1980, 46 (06): : 535 - 538
  • [25] A LIQUID ION-SELECTIVE ELECTRODE FOR DETERMINING ALKYLSULFATES
    STAROBINETS, GL
    LAEVSKAYA, GA
    RAKHMANKO, EM
    PIROZHNIKOVA, AK
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1980, 35 (01): : 116 - 119
  • [27] LIQUID ION-SELECTIVE ELECTRODE FOR DETERMINATION OF TECHNETIUM
    AKOPOV, GA
    ABDULAKHATOV, MK
    KRINITSYN, AP
    SOVIET RADIOCHEMISTRY, 1986, 28 (03): : 396 - 399
  • [28] FILM ION-SELECTIVE ELECTRODES WITH SOLID CONTACT
    GREKOVICH, AL
    VESTNIK LENINGRADSKOGO UNIVERSITETA SERIYA FIZIKA KHIMIYA, 1980, (03): : 68 - 73
  • [29] DETERMINATION OF SULFUR IN SOLID AND LIQUID SAMPLES BY POTENTIOMETRIC TITRATION WITH ION-SELECTIVE ELECTRODE
    DEMEDINA, HL
    GONZALEZ, G
    DURAN, J
    ANALYTICAL LETTERS, 1994, 27 (03) : 625 - 641
  • [30] Pulsed NMR analysis of ion-selective electrode membranes
    Moriuchi-Kawakami, Takayo
    Kizuki, Maremi
    Takeuchi, Hidekazu
    Shibutani, Yasuhiko
    ANALYST, 2011, 136 (05) : 897 - 900