Amperometric sensing of sulfite using a gold electrode coated with ordered mesoporous carbon modified with nickel hexacyanoferrate

被引:25
|
作者
Preecharueangrit, Supatcha [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
关键词
Sulfite; Ordered mesoporous carbon; Nickel hexacyanoferrate; Amperometric detection; Flow injection; FLOW-INJECTION ANALYSIS; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSOR; ION CHROMATOGRAPHY; SULFUR-DIOXIDE; NANOPARTICLES; ACID; FOOD; NANOCOMPOSITE; NANOTUBES;
D O I
10.1016/j.jelechem.2017.11.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric sulfite sensor was fabricated based on nickel hexacyanoferrate (NiHCF) electrodeposited on a layer of ordered mesoporous carbon covering on a gold electrode surface (NiHCF/OMC/Au). The prepared NiHCF/OMC/Au displayed good electrocatalytic activity towards the oxidation of sulfite. The sulfite response was determined at an optimal applied potential of 0.40 V vs Ag/AgCl in a flow injection analysis system. Under optimum conditions, the sensor has a linear response in the 2.5 mu M to 50 mM sulfite concentration range and a 2.5 mu M limit of detection (at an S/N ratio of 3). The electrode has a high operational stability, can be used up to 104 times (with a RSD of 5.9%), and a good electrode-to-electrode repeatability (with an RSD of <7.0%, for n = 6). It was applied, in the flow injection mode, to analyze sulfite in vermicelli, instant noodles, noodles, and macaroni. Recoveries of spiked samples ranged of from 80 +/- 1 to 108 +/- 2%, and the results agreed well with the Monier-Williams AOAC official method.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 50 条
  • [31] A sensitive and selective on-line amperometric sulfite biosensor using sulfite oxidase immobilized on a magnetite-gold-folate nanocomposite modified carbon-paste electrode
    Sroysee, Wongduan
    Ponlakhet, Kitayanan
    Chairam, Sanoe
    Jarujamrus, Purim
    Amatatongchai, Maliwan
    TALANTA, 2016, 156 : 154 - 162
  • [32] A Flow Injection Amperometric Sensor for Nitrate Detection Based on Cu Foam/Ordered Mesoporous Carbon Modified Glassy Carbon Electrode
    Junlapak, Nuttakorn
    Numnuam, Apon
    Nontipichet, Natha
    Kangkamano, Tawatchai
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Khumngern, Suntisak
    CHEMNANOMAT, 2024, 10 (06)
  • [33] Nonenzymatic glucose detection at ordered mesoporous carbon modified electrode
    Ndamanisha, Jean Chrysostome
    Guo, Liping
    BIOELECTROCHEMISTRY, 2009, 77 (01) : 60 - 63
  • [34] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [35] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [36] Cerium hexacyanoferrate/ordered mesoporous carbon electrode and its application in electrochemical determination of hydrous hydrazine
    Yang, Haijing
    Lu, Baoping
    Guo, Liping
    Qi, Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) : 171 - 175
  • [37] Electrochemical detection of natural estrogens using a graphene/ordered mesoporous carbon modified carbon paste electrode
    Zhu, Yanqiong
    Liu, Xiangjian
    Jia, Jianbo
    ANALYTICAL METHODS, 2015, 7 (20) : 8626 - 8631
  • [38] Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine
    Sabzi, Reza Emamali
    Minaie, Elnaz
    Farhadi, Khalil
    Golzan, Mir Maqsoud
    TURKISH JOURNAL OF CHEMISTRY, 2010, 34 (06) : 901 - 910
  • [39] Development of selective electrochemical detector for hydrazine in water samples using nickel hexacyanoferrate modified disposable gold electrode
    Barathi, Palani
    Kumar, Annamalai Senthil
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) : 451 - 454
  • [40] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):