Cerium hexacyanoferrate/ordered mesoporous carbon electrode and its application in electrochemical determination of hydrous hydrazine

被引:56
|
作者
Yang, Haijing [1 ]
Lu, Baoping [1 ]
Guo, Liping [1 ]
Qi, Bin [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Peoples R China
关键词
Ordered mesoporous carbon; Cerium hexacyanoferrate; Hydrous hydrazine; Electrocatalysis; ELECTROCATALYTIC OXIDATION; SPECTROPHOTOMETRIC DETERMINATION; PORE CHARACTERISTICS; PERFORMANCE; COMPOSITE; SULFITE; SENSOR;
D O I
10.1016/j.jelechem.2010.10.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Via electrochemical polymerization process, cerium hexacyanoferrate/ordered mesoporous carbon modified glass carbon electrode (CeHCF/OMC/GCE) was prepared. The new hybrid material of modified electrode was characterized by cyclic voltammetry (CV) and scanning electron microscopy (SEM), and the as-prepared CeHCF/OMC/GCE was used for the detection of hydrous hydrazine. The results show that the present electrode exhibits some good behaviors such as excellent reproducibility, fast response time, easy preparation, and so on. Under the selected conditions, the linear relationship between the current response and hydrous hydrazine concentration is in the range from 1 to 163 mu mol/L with a correlation coefficient of 0.998 (n = 10), and the detection limit is 0.1 mu mol/L (S/N = 3). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 50 条
  • [1] Formation of flowerlike gold nanostructure on ordered mesoporous carbon electrode and its application in electrochemical determination of ractopamine
    Wei, Qinghe
    Wang, Qin
    Wang, Hongying
    Gu, Hongwei
    Zhang, Qingqing
    Gao, Xiang
    Qi, Bin
    MATERIALS LETTERS, 2015, 147 : 58 - 60
  • [2] Electrochemical Determination of Prednisolone at Ordered Mesoporous Carbon Modified Electrode: Application to Doping Monitoring
    Munyentwali, Alexis
    Zhu, Liande
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (04) : H278 - H282
  • [3] Amperometric determination of hydrazine using a CuS-ordered mesoporous carbon electrode
    Srinidhi, G.
    Sudalaimani, S.
    Giribabu, K.
    Basha, S. J. Sardhar
    Suresh, C.
    MICROCHIMICA ACTA, 2020, 187 (06)
  • [4] Amperometric determination of hydrazine using a CuS-ordered mesoporous carbon electrode
    G. Srinidhi
    S. Sudalaimani
    K. Giribabu
    S.J. Sardhar Basha
    C. Suresh
    Microchimica Acta, 2020, 187
  • [5] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [6] Electrochemical behaviors and determination of isoniazid at ordered mesoporous carbon modified electrode
    Yan, Xue
    Bo, Xiangjie
    Guo, Liping
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02): : 837 - 842
  • [7] Electrochemical determination of toxic ractopamine at an ordered mesoporous carbon modified electrode
    Yang, Xiao
    Feng, Bo
    Yang, Peng
    Ding, Yonglan
    Chen, Yi
    Fei, Junjie
    FOOD CHEMISTRY, 2014, 145 : 619 - 624
  • [8] Electrochemical properties of ordered mesoporous carbon and its electroanalytical application for selective determination of dopamine
    Jia, Nengqin
    Wang, Zhiyong
    Yang, Guofeng
    Shen, Hebai
    Zhu, Longzhang
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (02) : 233 - 238
  • [9] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Deng Pan
    Shumin Ma
    Xiangjie Bo
    Liping Guo
    Microchimica Acta, 2011, 173 : 215 - 221
  • [10] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Pan, Deng
    Ma, Shumin
    Bo, Xiangjie
    Guo, Liping
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 215 - 221