Electrochemical behaviors and determination of isoniazid at ordered mesoporous carbon modified electrode

被引:75
|
作者
Yan, Xue [1 ]
Bo, Xiangjie [1 ]
Guo, Liping [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Jilin, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 155卷 / 02期
基金
中国国家自然科学基金;
关键词
Ordered mesoporous carbon; Isoniazid; Electrochemical sensor; Amperometric determination; L-CYSTEINE; RIFAMPICIN; PYRAZINAMIDE; NANOPARTICLES; FORMULATIONS; OXIDATION; ASSAY; BULK;
D O I
10.1016/j.snb.2011.01.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 mu A/mu M, a low detection limit of 8.4 x 10(-8) M and wide linear range from 1.0 x 10(-7) M to 3.7 x 10(-4) M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:837 / 842
页数:6
相关论文
共 50 条
  • [1] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [2] Electrochemical determination of toxic ractopamine at an ordered mesoporous carbon modified electrode
    Yang, Xiao
    Feng, Bo
    Yang, Peng
    Ding, Yonglan
    Chen, Yi
    Fei, Junjie
    FOOD CHEMISTRY, 2014, 145 : 619 - 624
  • [3] Electrochemical Determination of Prednisolone at Ordered Mesoporous Carbon Modified Electrode: Application to Doping Monitoring
    Munyentwali, Alexis
    Zhu, Liande
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (04) : H278 - H282
  • [4] A sensitive electrochemical sensor for the determination of carvedilol based on a modified glassy carbon electrode with ordered mesoporous carbon
    Rofouei, Mohammad Kazem
    Khoshsafar, Hamid
    Kalbasi, Roozbeh Javad
    Bagheri, Hasan
    RSC ADVANCES, 2016, 6 (16): : 13160 - 13167
  • [5] Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    Jing Bai
    Liping Guo
    Jean Chrysostome Ndamanisha
    Bin Qi
    Journal of Applied Electrochemistry, 2009, 39 : 2497 - 2503
  • [6] Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    Bai, Jing
    Guo, Liping
    Ndamanisha, Jean Chrysostome
    Qi, Bin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2497 - 2503
  • [7] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Deng Pan
    Shumin Ma
    Xiangjie Bo
    Liping Guo
    Microchimica Acta, 2011, 173 : 215 - 221
  • [8] Electrochemical determination of bisphenol A at ordered mesoporous carbon modified nano-carbon ionic liquid paste electrode
    Li, Yonghong
    Zhai, Xiurong
    Liu, Xinsheng
    Wang, Ling
    Liu, Herong
    Wang, Haibo
    TALANTA, 2016, 148 : 362 - 369
  • [9] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Pan, Deng
    Ma, Shumin
    Bo, Xiangjie
    Guo, Liping
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 215 - 221
  • [10] Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode
    Rajaram, Rajendran
    Kumar, Sachin
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)