Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode

被引:0
|
作者
Rajaram, Rajendran [1 ]
Kumar, Sachin [1 ]
Ramanujam, Kothandaraman [2 ]
Neelakantan, Lakshman [1 ,3 ]
机构
[1] Indian Inst Technol Madras, Dept Met & Mat Engn, Corros Engn & Mat Electrochem Lab, Chennai 600036, India
[2] Indian Inst Technol Madras, Dept Chem, Clean Energy Lab, Chennai 600036, India
[3] Indian Inst Technol Madras, Ctr Excellence Mat & Mfg Futurist Mobil, Ceram Technol Grp, Chennai 600036, India
关键词
paraquat; CMK-3; GCE; anodic stripping squarewave voltammetry; limit of detection; vegetable and fruit extracts; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; WATER; DIQUAT; PERFORMANCE; ACTIVATION; BIOCHAR;
D O I
10.1149/1945-7111/acedd0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ordered mesoporous carbon namely, CMK-3 was synthesized by nano casting method, and characterized using various physicochemical and electroanalytical tools like HESEM, HRTEM, BET, etc. Using Cyclic voltammetric (CV) measurements on CMK-3 modified glassy carbon electrode (CMK-3/GCE) in the standard redox couple, [Fe(CN)(6)](3-/4-), the electrochemical surface area was deduced as 0.081 cm(2). The modified electrode was used as an electrocatalyst for the determination of one of the herbicides, paraquat (PQ). The modified electrode shows enhanced sensitivity for the determination of PQ in phosphate buffer solution at pH 9.2 as compared to bare GCE. The concentration dependant CV studies showed a linear variation in sensitivity in the concentration range of 60 & mu;M to 450 & mu;M. The effect of the scan rate shows a linear variation in sensitivity as a function of the square root of scan rate suggesting a diffusion-controlled process during the detection of PQ. Anodic stripping square wave voltammetry (ASSWV) reveals the sensitivity and limit of detection as 9.51 & mu;A & mu;M-1 and 64 nM, respectively. The interfering ability of the other foreign molecules like metal ions, environmental samples, biomolecules, and pesticides was analyzed using CMK-3/GCE. The results revealed that the electrode is able to sense paraquat, with the retention in sensitivity ranges between 91% and 102%. The real-time applicability of the electrode was examined using vegetable and fruit extracts. The analysis revealed that the recovery values were between 102 % - 105 %.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413
  • [2] Amperometric Determination of Hydrazine Using Au Nanoparticle Incorporated CMK-3 Modified Glassy Carbon Electrode
    Rajaram, Rajendran
    Kumar, Sachin
    Sudharsan, S.
    Raj, Rayappan Pavul
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)
  • [3] Cathodic electrochemiluminescence of luminol using polyaniline/ordered mesoporous carbon (CMK-3) hybrid modified electrode for signal amplification
    Dai, Hong
    Lin, Yanyu
    Xu, Guifang
    Gong, Linshan
    Yang, Caiping
    Ma, Xiuling
    Chen, Guonan
    ELECTROCHIMICA ACTA, 2012, 78 : 508 - 514
  • [4] EFFECTIVE THERMAL CONDUCTIVITY OF ORDERED MESOPOROUS CARBON CMK-3
    Feng, Daili
    Feng, Yanhui
    Zhang, Xinxin
    Wang, Ge
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 1, 2014,
  • [5] A sensitive electrochemical sensor for the determination of carvedilol based on a modified glassy carbon electrode with ordered mesoporous carbon
    Rofouei, Mohammad Kazem
    Khoshsafar, Hamid
    Kalbasi, Roozbeh Javad
    Bagheri, Hasan
    RSC ADVANCES, 2016, 6 (16): : 13160 - 13167
  • [6] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Deng Pan
    Shumin Ma
    Xiangjie Bo
    Liping Guo
    Microchimica Acta, 2011, 173 : 215 - 221
  • [7] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Pan, Deng
    Ma, Shumin
    Bo, Xiangjie
    Guo, Liping
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 215 - 221
  • [8] Synthesis of silver nanoparticles within ordered CMK-3 mesoporous carbon
    Cao, JM
    Cao, YL
    Chang, X
    Zheng, MB
    Liu, JS
    Ji, HM
    NANOPOROUS MATERIALS IV, 2005, 156 : 423 - 426
  • [9] Sensitive determination of Sudan I at an ordered mesoporous carbon modified glassy carbon electrode
    Yang, Dongxu
    Zhu, Liande
    Jiang, Xiaoyan
    Guo, Liping
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01): : 124 - 129
  • [10] Ordered Mesoporous Carbon CMK-3 Modified with Cu(I) for Selective Ethylene/Ethane Adsorption
    Jiang, Wen-Juan
    Sun, Lin-Bing
    Yin, Yu
    Song, Xue-Lin
    Liu, Xiao-Qin
    SEPARATION SCIENCE AND TECHNOLOGY, 2013, 48 (06) : 968 - 976