Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode

被引:0
|
作者
Rajaram, Rajendran [1 ]
Kumar, Sachin [1 ]
Ramanujam, Kothandaraman [2 ]
Neelakantan, Lakshman [1 ,3 ]
机构
[1] Indian Inst Technol Madras, Dept Met & Mat Engn, Corros Engn & Mat Electrochem Lab, Chennai 600036, India
[2] Indian Inst Technol Madras, Dept Chem, Clean Energy Lab, Chennai 600036, India
[3] Indian Inst Technol Madras, Ctr Excellence Mat & Mfg Futurist Mobil, Ceram Technol Grp, Chennai 600036, India
关键词
paraquat; CMK-3; GCE; anodic stripping squarewave voltammetry; limit of detection; vegetable and fruit extracts; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; WATER; DIQUAT; PERFORMANCE; ACTIVATION; BIOCHAR;
D O I
10.1149/1945-7111/acedd0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ordered mesoporous carbon namely, CMK-3 was synthesized by nano casting method, and characterized using various physicochemical and electroanalytical tools like HESEM, HRTEM, BET, etc. Using Cyclic voltammetric (CV) measurements on CMK-3 modified glassy carbon electrode (CMK-3/GCE) in the standard redox couple, [Fe(CN)(6)](3-/4-), the electrochemical surface area was deduced as 0.081 cm(2). The modified electrode was used as an electrocatalyst for the determination of one of the herbicides, paraquat (PQ). The modified electrode shows enhanced sensitivity for the determination of PQ in phosphate buffer solution at pH 9.2 as compared to bare GCE. The concentration dependant CV studies showed a linear variation in sensitivity in the concentration range of 60 & mu;M to 450 & mu;M. The effect of the scan rate shows a linear variation in sensitivity as a function of the square root of scan rate suggesting a diffusion-controlled process during the detection of PQ. Anodic stripping square wave voltammetry (ASSWV) reveals the sensitivity and limit of detection as 9.51 & mu;A & mu;M-1 and 64 nM, respectively. The interfering ability of the other foreign molecules like metal ions, environmental samples, biomolecules, and pesticides was analyzed using CMK-3/GCE. The results revealed that the electrode is able to sense paraquat, with the retention in sensitivity ranges between 91% and 102%. The real-time applicability of the electrode was examined using vegetable and fruit extracts. The analysis revealed that the recovery values were between 102 % - 105 %.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Sorption study of uranium from aqueous solution on ordered mesoporous carbon CMK-3
    Nie, Bin-wen
    Zhang, Zhi-bin
    Cao, Xiao-hong
    Liu, Yun-hai
    Liang, Ping
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (01) : 663 - 670
  • [22] Development of modified mesoporous carbon (CMK-3) for improved adsorption of bisphenol-A
    Jeong, Yunjae
    Cui, Mingcan
    Choi, Jongbok
    Lee, Yonghyeon
    Kim, Jeonggwan
    Son, Younggyu
    Khim, Jeehyeong
    CHEMOSPHERE, 2020, 238 (238)
  • [23] Sorption study of uranium from aqueous solution on ordered mesoporous carbon CMK-3
    Bin-wen Nie
    Zhi-bin Zhang
    Xiao-hong Cao
    Yun-hai Liu
    Ping Liang
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 663 - 670
  • [24] Ordered mesoporous magnesium oxide with high thermal stability synthesized by exotemplating using CMK-3 carbon
    Roggenbuck, J
    Tiemann, M
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (04) : 1096 - 1097
  • [25] Electrochemical determination of Tannins using multiwall carbon nanotubes modified glassy carbon electrode
    Lü, SF
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2004, 40 (07) : 750 - 754
  • [26] Electrochemical Determination of Tannins Using Multiwall Carbon Nanotubes Modified Glassy Carbon Electrode
    Shaofang Lü
    Russian Journal of Electrochemistry, 2004, 40 : 750 - 754
  • [27] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Lemma Teshome Tufa
    Khalid Siraj
    Tesfaye Refera Soreta
    Russian Journal of Electrochemistry, 2013, 49 : 59 - 66
  • [28] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Tufa, Lemma Teshome
    Siraj, Khalid
    Soreta, Tesfaye Refera
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (01) : 59 - 66
  • [29] A glassy carbon electrode modified with carbon nanoonions for electrochemical determination of fentanyl
    Sohouli, Esmail
    Keihan, Amir Homayoun
    Shahdost-fard, Faezeh
    Naghian, Ebrahim
    Plonska-Brzezinska, Marta E.
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [30] A hydrogen sorption study on a Pd-doped CMK-3 type ordered mesoporous carbon
    Giasafaki, D.
    Charalambopoulou, G.
    Bourlinos, A.
    Stubos, A.
    Gournis, D.
    Steriotis, Th.
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2013, 19 (2-4): : 803 - 811