Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode

被引:0
|
作者
Rajaram, Rajendran [1 ]
Kumar, Sachin [1 ]
Ramanujam, Kothandaraman [2 ]
Neelakantan, Lakshman [1 ,3 ]
机构
[1] Indian Inst Technol Madras, Dept Met & Mat Engn, Corros Engn & Mat Electrochem Lab, Chennai 600036, India
[2] Indian Inst Technol Madras, Dept Chem, Clean Energy Lab, Chennai 600036, India
[3] Indian Inst Technol Madras, Ctr Excellence Mat & Mfg Futurist Mobil, Ceram Technol Grp, Chennai 600036, India
关键词
paraquat; CMK-3; GCE; anodic stripping squarewave voltammetry; limit of detection; vegetable and fruit extracts; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; WATER; DIQUAT; PERFORMANCE; ACTIVATION; BIOCHAR;
D O I
10.1149/1945-7111/acedd0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ordered mesoporous carbon namely, CMK-3 was synthesized by nano casting method, and characterized using various physicochemical and electroanalytical tools like HESEM, HRTEM, BET, etc. Using Cyclic voltammetric (CV) measurements on CMK-3 modified glassy carbon electrode (CMK-3/GCE) in the standard redox couple, [Fe(CN)(6)](3-/4-), the electrochemical surface area was deduced as 0.081 cm(2). The modified electrode was used as an electrocatalyst for the determination of one of the herbicides, paraquat (PQ). The modified electrode shows enhanced sensitivity for the determination of PQ in phosphate buffer solution at pH 9.2 as compared to bare GCE. The concentration dependant CV studies showed a linear variation in sensitivity in the concentration range of 60 & mu;M to 450 & mu;M. The effect of the scan rate shows a linear variation in sensitivity as a function of the square root of scan rate suggesting a diffusion-controlled process during the detection of PQ. Anodic stripping square wave voltammetry (ASSWV) reveals the sensitivity and limit of detection as 9.51 & mu;A & mu;M-1 and 64 nM, respectively. The interfering ability of the other foreign molecules like metal ions, environmental samples, biomolecules, and pesticides was analyzed using CMK-3/GCE. The results revealed that the electrode is able to sense paraquat, with the retention in sensitivity ranges between 91% and 102%. The real-time applicability of the electrode was examined using vegetable and fruit extracts. The analysis revealed that the recovery values were between 102 % - 105 %.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A hydrogen sorption study on a Pd-doped CMK-3 type ordered mesoporous carbon
    D. Giasafaki
    G. Charalambopoulou
    A. Bourlinos
    A. Stubos
    D. Gournis
    Th. Steriotis
    Adsorption, 2013, 19 : 803 - 811
  • [32] Electrochemical Oxidation and Detection of Morphine at Ordered Mesoporous Carbon Modified Glassy Carbon Electrodes
    Bo, Xiangjie
    Xie, Wenlin
    Ndamanisha, Jean Chrysostome
    Bai, Jing
    Guo, Liping
    ELECTROANALYSIS, 2009, 21 (23) : 2549 - 2555
  • [33] Enhanced CO2 Sorption on Ordered Mesoporous Carbon CMK-3 in the Presence of Water
    Zhou, Jia
    Su, Wei
    Sun, Yan
    Deng, Shuguang
    Wang, Xiaojing
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2016, 61 (03): : 1348 - 1352
  • [34] Nickel oxide nanocrystallites within the wall of ordered mesoporous carbon CMK-3: Synthesis and characterization
    Li, HF
    Zhu, SM
    Xi, HA
    Wang, RD
    MICROPOROUS AND MESOPOROUS MATERIALS, 2006, 89 (1-3) : 196 - 203
  • [35] Electrochemical behavior of L-cysteine and its detection at ordered mesoporous carbon-modified glassy carbon electrode
    Zhou, Ming
    Ding, Jie
    Guo, Li-ping
    Shang, Qing-kun
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5328 - 5335
  • [36] Electrochemical Determination of Prednisolone at Ordered Mesoporous Carbon Modified Electrode: Application to Doping Monitoring
    Munyentwali, Alexis
    Zhu, Liande
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (04) : H278 - H282
  • [37] Synthesis of ordered mesoporous zinc oxide obtained by dry gel nanocasting from the mesoporous carbon CMK-3
    Thiel, Helwig H.
    de Paza, Pablo Cascales
    Hartmann, Martin
    Ernst, Stefan
    RECENT PROGRESS IN MESOSTRUCTURED MATERIALS, PROCEEDINGS OF THE 5TH INTERNATIONAL MESOSTRUCTURED MATERIALS SYMPOSIUM - IMMS2006, 2007, 165 : 243 - 246
  • [38] Efficient desulfurization of fuel with functionalized mesoporous carbon CMK-3-O and comparison its performance with mesoporous carbon CMK-3
    Nejad, N. Farzin
    Shams, E.
    Amini, M. K.
    Choolaei, M.
    FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2016, 24 (12) : 786 - 795
  • [39] Electrochemical detection of natural estrogens using a graphene/ordered mesoporous carbon modified carbon paste electrode
    Zhu, Yanqiong
    Liu, Xiangjian
    Jia, Jianbo
    ANALYTICAL METHODS, 2015, 7 (20) : 8626 - 8631
  • [40] Electrochemical determination of bisphenol A at ordered mesoporous carbon modified nano-carbon ionic liquid paste electrode
    Li, Yonghong
    Zhai, Xiurong
    Liu, Xinsheng
    Wang, Ling
    Liu, Herong
    Wang, Haibo
    TALANTA, 2016, 148 : 362 - 369