Combination Doppler backscattering/cross-polarization scattering diagnostic for the C-2W field-reversed configuration

被引:4
|
作者
Schmitz, L. [1 ,2 ]
Deng, B. [2 ]
Thompson, M. [2 ]
Gota, H. [2 ]
Lau, C. [2 ]
Fulton, D. P. [2 ]
Lin, Z. [3 ]
Tajima, T. [2 ,3 ]
Binderbauer, M. [2 ]
机构
[1] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
[2] TAE Technol Inc, Foothill Ranch, CA 92610 USA
[3] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
MAGNETIC FLUCTUATIONS; ELECTROMAGNETIC-WAVE; PLASMA; TURBULENCE; ION;
D O I
10.1063/1.5038914
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A versatile combination Doppler backscattering and Cross-Polarization Scattering (CPS) diagnostic for the C-2W beam-driven field-reversed configuration is described. This system is capable of measuring density fluctuations and perpendicular magnetic field fluctuations across a wide wavenumber range ( 2.5 <= k theta rho(s) <= 50), with typical resolution Delta k(theta)/k(theta) <= 0.4-0.8. Four tunable frequencies (26 GHz <= f <= 60 GHz corresponding to plasma cut-off densities 0.8 x 10(19) <= n(e) <= 4.4 x 10(19) m(-3)) are launched via quasi-optical beam combiners/polarizers and an adjustable parabolic focusing mirror selecting the beam incidence angle. GENRAY ray tracing shows that the incident O-mode and backscattered CPS X-mode beam trajectories for C-2W plasma parameters nearly overlap, allowing simultaneous detection of (n) over tilde and (B) over tilde (r) or (B) over tilde (theta) from essentially the same scattering volume. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 42 条
  • [31] A 12-barrel deuterium pellet injector for the C-2 field-reversed configuration device
    I. V. Vinyar
    A. Ya. Lukin
    S. V. Skoblikov
    P. V. Reznichenko
    E. Trask
    M. Wyman
    A. Smirnov
    Instruments and Experimental Techniques, 2014, 57 : 508 - 515
  • [32] A SEARCH FOR LOWER-HYBRID-DRIFT FLUCTUATIONS IN A FIELD-REVERSED CONFIGURATION USING CO2 HETERODYNE SCATTERING
    CARLSON, AW
    PHYSICS OF FLUIDS, 1987, 30 (05) : 1497 - 1509
  • [33] Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device
    Granstedt, E. M.
    Petrov, P.
    Knapp, K.
    Cordero, M.
    Patel, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [34] Development of a magnetized coaxial plasma gun for compact toroid injection into the C-2 field-reversed configuration device
    Matsumoto, T.
    Sekiguchi, J.
    Asai, T.
    Gota, H.
    Garate, E.
    Allfrey, I.
    Valentine, T.
    Morehouse, M.
    Roche, T.
    Kinley, J.
    Aefsky, S.
    Cordero, M.
    Waggoner, W.
    Binderbauer, M.
    Tajima, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [35] Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment
    Sheftman, D.
    Gupta, D.
    Roche, T.
    Thompson, M. C.
    Giammanco, F.
    Conti, F.
    Marsili, P.
    Moreno, C. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [36] Improved density profile measurements in the C-2U advanced beam-driven Field-Reversed Configuration (FRC) plasmas
    Beall, M.
    Deng, B. H.
    Gota, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [37] Calibration and applications of visible imaging cameras on the C-2U advanced beam-driven field-reversed configuration device
    Granstedt, E. M.
    Fallah, D.
    Thompson, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [38] Achievement of field-reversed configuration plasma sustainment via 10 MW neutral-beam injection on the C-2U device
    Gota, H.
    Binderbauer, M. W.
    Tajima, T.
    Putvinski, S.
    Tuszewski, M.
    Dettrick, S.
    Garate, E.
    Korepanov, S.
    Smirnov, A.
    Thompson, M. C.
    Trask, E.
    Yang, X.
    Schmitz, L.
    Lin, Z.
    Ivanov, A. A.
    Asai, T.
    Allfrey, I.
    Andow, R.
    Beall, M.
    Bolte, N.
    Bui, D. Q.
    Cappello, M.
    Ceccherini, F.
    Clary, R.
    Cheung, A. H.
    Conroy, K.
    Deng, B. H.
    Douglass, J.
    Dunaevsky, A.
    Feng, P.
    Fulton, D.
    Galeotti, L.
    Granstedt, E.
    Griswold, M.
    Gupta, D.
    Gupta, S.
    Hubbard, K.
    Isakov, I.
    Kinley, J. S.
    Knapp, K.
    Magee, R.
    Matvienko, V.
    Mendoza, R.
    Mok, Y.
    Necas, A.
    Primavera, S.
    Onofri, M.
    Osin, D.
    Rath, N.
    Roche, T.
    NUCLEAR FUSION, 2017, 57 (11)
  • [39] High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas
    Deng, B. H.
    Beall, M.
    Schroeder, J.
    Settles, G.
    Feng, P.
    Kinley, J. S.
    Gota, H.
    Thompson, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [40] Far infrared laser polarimetry and far forward scattering diagnostics for the C-2 field reversed configuration plasmas
    Deng, B. H.
    Kinley, J. S.
    Knapp, K.
    Feng, P.
    Martinez, R.
    Weixel, C.
    Armstrong, S.
    Hayashi, R.
    Longman, A.
    Mendoza, R.
    Gota, H.
    Tuszewski, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):