A 12-barrel deuterium pellet injector for the C-2 field-reversed configuration device

被引:0
|
作者
I. V. Vinyar
A. Ya. Lukin
S. V. Skoblikov
P. V. Reznichenko
E. Trask
M. Wyman
A. Smirnov
机构
[1] PELIN LLC.,
[2] Tri Alpha Energy Inc.,undefined
关键词
Valve Seat; Slide Valve; Injector Operation; Evacuation Line; Pellet Velocity;
D O I
暂无
中图分类号
学科分类号
摘要
A compact 12-barrel deuterium pellet injector for plasma studies in the C-2 field-reversed configuration device (USA) is described. As in other multibarrel injectors, pellets are simultaneously formed inside short barrel segments that are cooled to 8–10 K. The injector has such features as low pellet velocities (up to 50 m/s), which are provided by a puncher mechanism built into the gas-admission valves, and the capability of plasma fueling with a pellet “needle” with a length-to-diameter ratio of up to 15.
引用
收藏
页码:508 / 515
页数:7
相关论文
共 50 条
  • [1] A 12-barrel deuterium pellet injector for the C-2 field-reversed configuration device
    Vinyar, I. V.
    Lukin, A. Ya.
    Skoblikov, S. V.
    Reznichenko, P. V.
    Trask, E.
    Wyman, M.
    Smirnov, A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2014, 57 (04) : 508 - 515
  • [2] A HIGH PERFORMANCE FIELD-REVERSED CONFIGURATION REGIME IN THE C-2 DEVICE
    Gota, H.
    Tuszewski, M.
    Smirnov, A.
    Korepanov, S.
    Akhmetov, T.
    Ivanov, A.
    Voskoboynikov, R.
    Binderbauer, M. W.
    Guo, H. Y.
    Barnes, D.
    Aefsky, S.
    Brown, R.
    Bui, D. Q.
    Clary, R.
    Conroy, K. D.
    Deng, B. H.
    Dettrick, S. A.
    Douglass, J. D.
    Garate, E.
    Glass, F. J.
    Gupta, D.
    Gupta, S.
    Kinley, J. S.
    Knapp, K.
    Hollins, M.
    Longman, A.
    Li, X. L.
    Luo, Y.
    Mendoza, R.
    Mok, Y.
    Necas, A.
    Primavera, S.
    Osin, D.
    Rostoker, N.
    Ruskov, E.
    Schmitz, L.
    Schroeder, J. H.
    Sevier, L.
    Sibley, A.
    Song, Y.
    Sun, X.
    Tajima, T.
    Thompson, M. C.
    Trask, E.
    Van Drie, A. D.
    Walters, J. K.
    Wyman, M. D.
    Zhai, K.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 63 (1T) : 139 - 142
  • [3] Feasibility Study of Microwave Electron Heating on the C-2 Field-Reversed Configuration Device
    Yang, Xiaokang
    Koehn, Alf
    Petrov, Yuri
    Ceccherini, Francesco
    Dettrick, Sean
    Binderbauer, Michl
    RADIOFREQUENCY POWER IN PLASMAS, 2015, 1689
  • [4] IMPROVED CONFINEMENT OF C-2 FIELD-REVERSED CONFIGURATION PLASMAS
    Gota, H.
    Tuszewski, M.
    Trask, E.
    Garate, E.
    Binderbauer, M. W.
    Tajima, T.
    Schmitz, L.
    Deng, B. H.
    Guo, H. Y.
    Aefsky, S.
    Allfrey, I.
    Barnes, D.
    Bolte, N.
    Bui, D. Q.
    Ceccherini, F.
    Clary, R.
    Conroy, K. D.
    Cordero, M.
    Dettrick, S. A.
    Douglass, J. D.
    Feng, P.
    Granstedt, E.
    Gupta, D.
    Gupta, S.
    Hooper, C.
    Kinley, J. S.
    Knapp, K.
    Korepanov, S.
    Longman, A.
    Magee, R.
    Mendoza, R.
    Mok, Y.
    Necas, A.
    Primavera, S.
    Putvinski, S.
    Onofri, M.
    Osin, D.
    Rath, N.
    Roche, T.
    Romero, J.
    Rostoker, N.
    Schroeder, J. H.
    Sevier, L.
    Sibley, A.
    Smirnov, A.
    Song, Y.
    Steinhauer, L. C.
    Thompson, M. C.
    Valentine, T.
    van Drie, A. D.
    FUSION SCIENCE AND TECHNOLOGY, 2015, 68 (01) : 44 - 49
  • [5] Internal magnetic field measurement on C-2 field-reversed configuration plasmas
    Gota, H.
    Thompson, M. C.
    Knapp, K.
    Van Drie, A. D.
    Deng, B. H.
    Mendoza, R.
    Guo, H. Y.
    Tuszewski, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [6] Overview of C-2 field-reversed configuration experiment plasma diagnostics
    Gota, H.
    Thompson, M. C.
    Tuszewski, M.
    Binderbauer, M. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [7] Langmuir probe diagnostic suite in the C-2 field-reversed configuration
    Roche, T.
    Sun, X.
    Armstrong, S.
    Knapp, K.
    Slepchenkov, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [8] Development of a magnetized coaxial plasma gun for compact toroid injection into the C-2 field-reversed configuration device
    Matsumoto, T.
    Sekiguchi, J.
    Asai, T.
    Gota, H.
    Garate, E.
    Allfrey, I.
    Valentine, T.
    Morehouse, M.
    Roche, T.
    Kinley, J.
    Aefsky, S.
    Cordero, M.
    Waggoner, W.
    Binderbauer, M.
    Tajima, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [9] Magnetic diagnostic suite of the C-2 field-reversed configuration experiment confinement vessel
    Thompson, M. C.
    Douglass, J. D.
    Feng, P.
    Knapp, K.
    Luo, Y.
    Mendoza, R.
    Patel, V.
    Tuszewski, M.
    Van Drie, A. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [10] Modulated active charge exchange fast ion diagnostic for the C-2 field-reversed configuration experiment
    Korepanov, S.
    Smirnov, A.
    Clary, R.
    Dettrick, S.
    Deichuli, P.
    Kondakov, A.
    Murakhtin, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):