Chaotic Phase Space Differential (CPSD) Algorithm for Real-Time Detection of VF, VT, and PVC ECG Signals

被引:0
|
作者
Liu, Chien-Sheng [1 ]
Lin, Yu-Chiun [1 ]
Chuang, Yueh-Hsun [1 ,4 ]
Hsiao, Tze-Chien [2 ]
Lin, Chii-Wann [1 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei, Taiwan
[2] Natl Chiao Tung Univ, Dept Comp Sci, Hsinchu 30050, Taiwan
[3] Natl Taiwan Univ, Inst Biomed Engn, Taipei, Taiwan
[4] Far Eastern Memorial Hosp, Dept Anesthesia, Taipei, Taiwan
关键词
electrocardiography; Phase Space Reconstruction; implantable; real-time analysis; telemedicine;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The continuous evolution of electrocardiography (ECG) recording has enabled the successful development of many significant applications of this vital signal for clinical diagnosis and monitoring. Recent trends in device miniaturization and wireless transmission have extended the uses of such a signal modality to telemedicine for home cares. However, it has posted new technical challenges for the scenarios of home users and associated business models. Among them, a smart algorithm for real time or early indication of critical cardiac conditions, e.g. ventricular fibrillation (VF), Ventricular Tachycardia (VT), are extremely important for sharing the work loads of remote side for proper responses and delivery of health care. It would be also rather critical to fit such a computation task into the wearable or mobile device for the requirement of low power consumption. In this paper, we report the development of a novel analysis algorithm based on Time-Delayed Phase Space Reconstruction (PSR) method to differentiate abnormal ECG segments from entire records. We used BIH-MIT arrhythmia database and CU database to verify our original ideas. According to our test results, this algorithm successfully identified the three heart diseases of PVC (Premature Ventricular Contraction), VF (Ventricular Fibrillation) and VT (Ventricular Tachycardia) immediately. We calculated the statistic parameters to estimate the efficiency: the average of sensitivity is 98.7% and the specificity reaches 96.2%. We also implemented this algorithm for wearable applications in a single-chip micro controller (MSP430, TI) for arrhythmia ECG data. The total code size is about a few hundred bytes and the execute time meets the order of sub-second. This new algorithm provides a powerful real-time index for clinical diagnosis and long-term home-care applications.
引用
收藏
页码:18 / 21
页数:4
相关论文
共 50 条
  • [41] A Fast and Accurate Edge Detection Algorithm for Real-Time Deep-Space Autonomous Optical Navigation
    Xiao, Hao
    Fan, Yanming
    Zhang, Zhang
    Cheng, Xin
    PROCEEDINGS OF THE 2019 10TH IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT DATA ACQUISITION AND ADVANCED COMPUTING SYSTEMS - TECHNOLOGY AND APPLICATIONS (IDAACS), VOL. 2, 2019, : 601 - 604
  • [42] A Real-Time and Self-Calibrating Algorithm Based on Triaxial Accelerometer Signals for the Detection of Human Posture and Activity
    Curone, Davide
    Bertolotti, Gian Mario
    Cristiani, Andrea
    Secco, Emanuele Lindo
    Magenes, Giovanni
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (04): : 1098 - 1105
  • [43] Performance Evaluation of a Real-Time Phase Estimation Algorithm Applied to Intracortical Signals from Human Visual Cortex
    Grani, Fabrizio
    Soto-Sanchez, Cristina
    Rodil Doblado, Alfonso
    Dolores Grima, Maria
    Farfan, Fernando
    Val Calvo, Mikel
    Soo, Leili
    Waclawczyk, Dorota
    Manuel Ferrandez, Jose
    Gonzalez, Pablo
    Dolores Coves, Maria
    Alfaro, Arantxa
    Fernandez, Eduardo
    ARTIFICIAL INTELLIGENCE IN NEUROSCIENCE: AFFECTIVE ANALYSIS AND HEALTH APPLICATIONS, PT I, 2022, 13258 : 516 - 525
  • [44] Real-time coherent detection of phase modulated ultrashort pulses after time-to-space conversion and spatial demultiplexing
    Shayovitz, Dror
    Herrmann, Harald
    Sohler, Wolfgang
    Ricken, Raimund
    Silberhorn, Christine
    Marom, Dan M.
    OPTICS EXPRESS, 2014, 22 (25): : 31138 - 31145
  • [45] ECG-Multichannel Frontend for Quick Stimulus Response Based on FPGA with Implemented Real-Time, Online QRS Detection Algorithm
    Fritzsche, P.
    Niemoeller, S.
    Laqua, D.
    Husar, P.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 619 - 622
  • [46] Real-Time Gait Phase Detection Using Wearable Sensors for Transtibial Prosthesis Based on a kNN Algorithm
    Rattanasak, Atcharawan
    Uthansakul, Peerapong
    Uthansakul, Monthippa
    Jumphoo, Talit
    Phapatanaburi, Khomdet
    Sindhupakorn, Bura
    Rooppakhun, Supakit
    SENSORS, 2022, 22 (11)
  • [47] Real-time gait subphase detection using an EMG signal graph matching (ESGM) algorithm based on EMG signals
    Ryu, Jaehwan
    Kim, Deok-Hwan
    EXPERT SYSTEMS WITH APPLICATIONS, 2017, 85 : 357 - 365
  • [48] Implementation of a Real-Time 60 Hz Interference Cancellation Algorithm for ECG Signals Based on ARM Cortex M4 and ADS1298
    Huamani R, R.
    Rendulich Talavera, Jorge
    Soto Mendoza, Enrique A.
    Davila, Nelly M.
    Supo, Elvis
    PROCEEDINGS OF THE 2017 IEEE XXIV INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL ENGINEERING AND COMPUTING (INTERCON), 2017,
  • [49] Fuzzy Logic based Implementation of a Real-Time Gait Phase Detection Algorithm using Kinematical Parameters for Walking
    Senanayake, C.
    Senanayake, S. M. N. Arosha
    2009 INTERNATIONAL CONFERENCE OF SOFT COMPUTING AND PATTERN RECOGNITION, 2009, : 586 - 591
  • [50] Row-level algorithm to improve real-time performance of glass tube defect detection in the production phase
    De Vitis, Gabriele A.
    Foglia, Pierfrancesco
    Prete, Cosimo A.
    IET IMAGE PROCESSING, 2020, 14 (12) : 2911 - 2921