Chaotic Phase Space Differential (CPSD) Algorithm for Real-Time Detection of VF, VT, and PVC ECG Signals

被引:0
|
作者
Liu, Chien-Sheng [1 ]
Lin, Yu-Chiun [1 ]
Chuang, Yueh-Hsun [1 ,4 ]
Hsiao, Tze-Chien [2 ]
Lin, Chii-Wann [1 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei, Taiwan
[2] Natl Chiao Tung Univ, Dept Comp Sci, Hsinchu 30050, Taiwan
[3] Natl Taiwan Univ, Inst Biomed Engn, Taipei, Taiwan
[4] Far Eastern Memorial Hosp, Dept Anesthesia, Taipei, Taiwan
关键词
electrocardiography; Phase Space Reconstruction; implantable; real-time analysis; telemedicine;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The continuous evolution of electrocardiography (ECG) recording has enabled the successful development of many significant applications of this vital signal for clinical diagnosis and monitoring. Recent trends in device miniaturization and wireless transmission have extended the uses of such a signal modality to telemedicine for home cares. However, it has posted new technical challenges for the scenarios of home users and associated business models. Among them, a smart algorithm for real time or early indication of critical cardiac conditions, e.g. ventricular fibrillation (VF), Ventricular Tachycardia (VT), are extremely important for sharing the work loads of remote side for proper responses and delivery of health care. It would be also rather critical to fit such a computation task into the wearable or mobile device for the requirement of low power consumption. In this paper, we report the development of a novel analysis algorithm based on Time-Delayed Phase Space Reconstruction (PSR) method to differentiate abnormal ECG segments from entire records. We used BIH-MIT arrhythmia database and CU database to verify our original ideas. According to our test results, this algorithm successfully identified the three heart diseases of PVC (Premature Ventricular Contraction), VF (Ventricular Fibrillation) and VT (Ventricular Tachycardia) immediately. We calculated the statistic parameters to estimate the efficiency: the average of sensitivity is 98.7% and the specificity reaches 96.2%. We also implemented this algorithm for wearable applications in a single-chip micro controller (MSP430, TI) for arrhythmia ECG data. The total code size is about a few hundred bytes and the execute time meets the order of sub-second. This new algorithm provides a powerful real-time index for clinical diagnosis and long-term home-care applications.
引用
收藏
页码:18 / 21
页数:4
相关论文
共 50 条
  • [31] A new real-time algorithm of wavelet transform for detection of sudden-changing signals of power systems
    Jianjun He
    Zhen Ren
    Wenying Huang
    Hong Zhou
    Tao Lin
    Science in China Series E: Technological Sciences, 1999, 42 : 609 - 615
  • [32] A new real-time algorithm of wavelet transform for detection of sudden-changing signals of power systems
    何建军
    任震
    黄雯莹
    周宏
    林涛
    Science in China(Series E:Technological Sciences), 1999, (06) : 609 - 615
  • [33] Performance of a real-time dicrotic notch detection and prediction algorithm in arrhythmic human aortic pressure signals
    Donelli A.
    Jansen J.R.C.
    Hoeksel B.
    Pedeferri P.
    Hanania R.
    Bovelander J.
    Maisano F.
    Castiglioni A.
    Alfieri O.
    Schreuder J.J.
    Journal of Clinical Monitoring and Computing, 2002, 17 (3-4) : 181 - 185
  • [34] A new real-time algorithm of wavelet transform for detection of sudden-changing signals of power systems
    He, JJ
    Ren, Z
    Huang, WY
    Zhou, H
    Lin, T
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 1999, 42 (06): : 609 - 615
  • [35] Detecting PVC Beats by Beat-by-beat Analysis of ECG Signals Using Machine Learning Classifiers for Real-time Predictive Cardiac Health Monitoring
    Tsai, I. Hua
    Morshed, Bashir I.
    2022 IEEE 13TH ANNUAL UBIQUITOUS COMPUTING, ELECTRONICS & MOBILE COMMUNICATION CONFERENCE (UEMCON), 2022, : 355 - 361
  • [36] Real-time measurement of nano-particle size using differential optical phase detection
    李晴
    黄河
    林峯
    吴兴坤
    ChineseOpticsLetters, 2017, 15 (12) : 19 - 23
  • [37] Real-time measurement of nano-particle size using differential optical phase detection
    Li, Qing
    Huang, He
    Lin, Feng
    Wu, Xingkun
    CHINESE OPTICS LETTERS, 2017, 15 (12)
  • [38] Real-Time Patient-Specific ECG Arrhythmia Detection by Quantum Genetic Algorithm of Least Squares Twin SVM
    Duan Li
    Ruizheng Shi
    Ni Yao
    Fubao Zhu
    Ke Wang
    Journal of Beijing Institute of Technology, 2020, 29 (01) : 29 - 37
  • [39] Algorithm for real-time detection of signal patterns using phase synchrony: an application to an electrode array
    Sadeghi, Saman
    MacKay, William A.
    van Dam, R. Michael
    Thompson, Michael
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (02)
  • [40] Real-Time Patient-Specific ECG Arrhythmia Detection by Quantum Genetic Algorithm of Least Squares Twin SVM
    Li D.
    Shi R.
    Yao N.
    Zhu F.
    Wang K.