4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters

被引:1
|
作者
Juffermans, Joe F. [1 ]
van Assen, Hans C. [1 ]
te Kiefte, Bastiaan J. C. [1 ]
Ramaekers, Mitch J. F. G. [1 ,2 ,3 ,4 ]
van der Palen, Roel L. F. [5 ]
van den Boogaard, Pieter [1 ]
Adriaans, Bouke P. [2 ,3 ,4 ]
Wildberger, Joachim E. [3 ,4 ]
Dekkers, Ilona A. [1 ]
Scholte, Arthur J. H. A. [6 ]
Schalla, Simon [2 ,3 ,4 ]
Lamb, Hildo J. [1 ]
Westenberg, Jos J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6229 HX Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, NL-6229 HX Maastricht, Netherlands
[4] Cardiovasc Res Inst Maastricht, NL-6229 HX Maastricht, Netherlands
[5] Leiden Univ, Med Ctr, Dept Pediat, Div Pediat Cardiol, NL-2333 ZA Leiden, Netherlands
[6] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
aorta; aneurysm; hemodynamic; 4D flow MRI; reproducibility; WALL SHEAR-STRESS; VALVE; QUANTIFICATION; ACCURACY; DIAMETER; PATTERNS; VELOCITY; SIZE;
D O I
10.3390/app12083912
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 +/- 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16-30% and ICC = 0.84-0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3-26% and ICC = 0.87-1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3-10% and ICC = 0.96-1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Cerebral hemodynamic changes of Takayasu arteritis based on 4D flow MRI
    Liu, Y.
    Sun, A.
    Ma, L.
    Jiang, L.
    Wang, H.
    Ding, J.
    Wang, X.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (1_SUPPL): : 218 - 218
  • [42] Quantitative 4D flow MRI-derived thoracic aortic normal values of 2D flow MRI parameters in healthy volunteers
    Ebel, Sebastian
    Kuehn, Alexander
    Koehler, Benjamin
    Behrendt, Benjamin
    Riekena, Boris
    Preim, Bernhard
    Denecke, Timm
    Grothoff, Matthias
    Gutberlet, Matthias
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (03): : 273 - 282
  • [43] Impact of sequence type and field strength (1.5, 3, and 7T) on 4D flow MRI hemodynamic aortic parameters in healthy volunteers
    Wiesemann, Stephanie
    Schmitter, Sebastian
    Demir, Aylin
    Prothmann, Marcel
    Schwenke, Carsten
    Chawla, Ashish
    von Knobelsdorff-Brenkenhoff, Florian
    Greiser, Andreas
    Jin, Ning
    Bollache, Emilie
    Markl, Michael
    Schulz-Menger, Jeanette
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) : 721 - 733
  • [44] 4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease
    Hope, Michael D.
    Hope, Thomas A.
    Crook, Stephen E. S.
    Ordovas, Karen G.
    Urbania, Thomas H.
    Alley, Marc T.
    Higgins, Charles B.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (07) : 781 - 787
  • [45] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [46] Editorial for "Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI"
    Soulat, Gilles
    Mousseaux, Elie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (06) : 1764 - 1765
  • [47] Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework
    Wang, Tianai
    Quast, Christine
    Boenner, Florian
    Kelm, Malte
    Zeus, Tobias
    Lemainque, Teresa
    Steinseifer, Ulrich
    Neidlin, Michael
    PLOS COMPUTATIONAL BIOLOGY, 2025, 21 (03)
  • [48] 4D Flow MRI Quantification of Mitral and Tricuspid Regurgitation: Reproducibility and Consistency Relative to Conventional MRI
    Feneis, Jennifer F.
    Kyubwa, Espoir
    Atianzar, Kimberly
    Cheng, Joseph Y.
    Alley, Marcus T.
    Vasanawala, Shreyas S.
    Demaria, Anthony N.
    Hsiao, Albert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (04) : 1147 - 1158
  • [49] Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom
    Montalba, Cristian
    Urbina, Jesus
    Sotelo, Julio
    Andia, Marcelo E.
    Tejos, Cristian
    Irarrazaval, Pablo
    Hurtado, Daniel E.
    Valverde, Israel
    Uribe, Sergio
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1882 - 1892
  • [50] Hemodynamic Parameters in the Parent Arteries of Unruptured Intracranial Aneurysms Depend on Aneurysm Size and Are Different Compared to Contralateral Arteries: A 7 Tesla 4D Flow MRI Study
    van Tuijl, Rick J.
    Timmins, Kimberley M.
    Velthuis, Birgitta K.
    van Ooij, Pim
    Zwanenburg, Jaco J. M.
    Ruigrok, Ynte M.
    van Der Schaaf, Irene C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, : 223 - 230