4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters

被引:1
|
作者
Juffermans, Joe F. [1 ]
van Assen, Hans C. [1 ]
te Kiefte, Bastiaan J. C. [1 ]
Ramaekers, Mitch J. F. G. [1 ,2 ,3 ,4 ]
van der Palen, Roel L. F. [5 ]
van den Boogaard, Pieter [1 ]
Adriaans, Bouke P. [2 ,3 ,4 ]
Wildberger, Joachim E. [3 ,4 ]
Dekkers, Ilona A. [1 ]
Scholte, Arthur J. H. A. [6 ]
Schalla, Simon [2 ,3 ,4 ]
Lamb, Hildo J. [1 ]
Westenberg, Jos J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6229 HX Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, NL-6229 HX Maastricht, Netherlands
[4] Cardiovasc Res Inst Maastricht, NL-6229 HX Maastricht, Netherlands
[5] Leiden Univ, Med Ctr, Dept Pediat, Div Pediat Cardiol, NL-2333 ZA Leiden, Netherlands
[6] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
aorta; aneurysm; hemodynamic; 4D flow MRI; reproducibility; WALL SHEAR-STRESS; VALVE; QUANTIFICATION; ACCURACY; DIAMETER; PATTERNS; VELOCITY; SIZE;
D O I
10.3390/app12083912
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 +/- 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16-30% and ICC = 0.84-0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3-26% and ICC = 0.87-1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3-10% and ICC = 0.96-1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Aortic dissection assessment by 4D phase-contrast MRI with hemodynamic parameters: the impact of stent type
    Chen, Chien-Wei
    Tseng, Yuan-Hsi
    Lin, Chien-Chao
    Kao, Chih-Chen
    Wong, Min Yi
    Ting, Hua
    Huang, Yao-Kuang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02) : 490 - 501
  • [22] Population-based reference values for 4D flow MRI derived aortic blood flow parameters
    Schafstedde, Marie
    Jarmatz, Lina
    Bruening, Jan
    Huellebrand, Markus
    Nordmeyer, Sarah
    Harloff, Andreas
    Hennemuth, Anja
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (03)
  • [23] Hemodynamic Changes Before and After Endovascular Treatment of Type B Aortic Dissection by 4D Flow MRI
    Cosset, Benoit
    Boussel, Loic
    Davila Serrano, Eduardo
    Millon, Antoine
    Douek, Philippe
    Farhat, Fadi
    Sigovan, Monica
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [24] Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI
    Kilinc, Ozden
    Chu, Stanley
    Baraboo, Justin
    Weiss, Elizabeth K.
    Engel, Joshua
    Maroun, Anthony
    Giese, Daniel
    Jin, Ning
    Chow, Kelvin
    Bi, Xiaoming
    Davids, Rachel
    Mehta, Christopher
    Malaisrie, S. Chris
    Hoel, Andrew
    Carr, James
    Markl, Michael
    Allen, Bradley D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (06) : 1752 - 1763
  • [25] Flow residence time in intracranial aneurysms evaluated by in vitro 4D flow MRI
    Li, Yinghui
    Amili, Omid
    Moen, Sean
    van de Moortele, Pierre-Francois
    Grande, Andrew
    Jagadeesan, Bharathi
    Coletti, Filippo
    JOURNAL OF BIOMECHANICS, 2022, 141
  • [26] Valvular and ascending aortic hemodynamics of the On-X aortic valved conduit by same-day echocardiography and 4D flow MRI
    Lee, Jeesoo
    Huh, Hyungkyu
    Scott, Michael B.
    Elbaz, Mohammed S. M.
    Puthumana, Jyothy J.
    Mccarthy, Patrick
    Malaisrie, S. Christopher
    Markl, Michael
    Thomas, James D.
    Barker, Alex J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [27] Flow residence time in intracranial aneurysms evaluated by in vitro 4D flow MRI
    Li, Yinghui
    Amili, Omid
    Moen, Sean
    Van de Moortele, Pierre-Francois
    Grande, Andrew
    Jagadeesan, Bharathi
    Coletti, Filippo
    JOURNAL OF BIOMECHANICS, 2022, 141
  • [28] Test-retest multisite reproducibility of neurovascular 4D flow MRI
    Wen, Baohong
    Tian, Shuping
    Cheng, Jingliang
    Li, Yinhua
    Zhang, Huixia
    Xue, Kangkang
    Zhang, Zanxia
    Fan, Yang
    Wu, Bing
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (06) : 1543 - 1552
  • [29] The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis
    Garcia, Julio
    Barker, Alex J.
    Markl, Michael
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (02) : 252 - 266
  • [30] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126